primary air flow rate rangeop # OPs
URI | https://saref.etsi.org/saref4bldg/primaryAirFlowRateMax |
---|---|
Description |
Maximum primary airflow that can be delivered. Usually measured in m3/s. |
https://saref.etsi.org/saref4bldg/
Information about changes compared to version 1.1.1: - Updated namespaces for compatibility with SAREF v3.
URI | https://saref.etsi.org/core/Actuator |
---|---|
Is Defined By | https://saref.etsi.org/core/ |
Description |
A device responsible for moving or controlling a mechanism or system |
Sub-classes |
Actuatorc |
URI | https://saref.etsi.org/core/Device |
---|---|
Is Defined By | https://saref.etsi.org/core/ |
Description |
A tangible object designed to accomplish a particular task in households, common public buildings or offices. In order to accomplish this task, the device performs one or more functions. For example, a washing machine is designed to wash (task) and to accomplish this task it performs the start and stop function. |
Super-classes |
Physical objectc |
Sub-classes |
Transport elementc Vibration isolatorc Building devicec |
URI | https://saref.etsi.org/core/Measurement |
---|---|
Is Defined By | https://saref.etsi.org/core/ |
Description |
Represents the measured value made over a property. It is also linked to the unit of measure in which the value is expressed and the timestamp of the measurement. |
Restrictions |
saref:hasTimestampfp only xsd:dateTimec saref:relatesToPropertyop only saref:Propertyc saref:isMeasuredInop exactly 1 saref:UnitOfMeasurec saref:relatesToPropertyop exactly 1 saref:Propertyc saref:isMeasuredInop only saref:UnitOfMeasurec |
URI | https://saref.etsi.org/core/Property |
---|---|
Is Defined By | https://saref.etsi.org/core/ |
Description |
An aspect of an entity that can be observable by a sensor. |
URI | https://saref.etsi.org/core/Sensor |
---|---|
Is Defined By | https://saref.etsi.org/core/ |
Description |
A device that detects and responds to events or changes in the physical environment such as light, motion, or temperature changes. A device that has category saref:Sensor and performs a saref:SensingFunction. |
Sub-classes |
Sensorc |
URI | https://saref.etsi.org/core/UnitOfMeasure |
---|---|
Is Defined By | https://saref.etsi.org/core/ |
Description |
The unit of measure is a standard for measurement of a quantity, such as a Property. For example, Power is a property and Watt is a unit of power that represents a definite predetermined power: when we say 10 Watt, we actually mean 10 times the definite predetermined power called "watt". Our definition is based on the definition of unit of measure in the Ontology of units of Measure (OM). We propose here a list of some units of measure that are relevant for the purpose of the Smart Appliances ontology, but this list can be extended. |
URI | https://saref.etsi.org/saref4bldg/Actuator |
---|---|
Description |
An actuator is a mechanical device for moving or controlling a mechanism or system. An actuator takes energy, usually created by air, electricity, or liquid, and converts that into some kind of motion. |
Super-classes |
Distribution control devicec saref:Actuatorc |
Restrictions |
fail positiondp only xsd:stringc manual overridedp only xsd:booleanc |
URI | https://saref.etsi.org/saref4bldg/AirToAirHeatRecovery |
---|---|
Description |
An air-to-air heat recovery device employs a counter-flow heat exchanger between inbound and outbound air flow. It is typically used to transfer heat from warmer air in one chamber to cooler air in the second chamber (i.e., typically used to recover heat from the conditioned air being exhausted and the outside air being supplied to a building), resulting in energy savings from reduced heating (or cooling) requirements. |
Super-classes |
Energy conversion devicec |
Restrictions |
heat transfer type enumdp only xsd:stringc primary air flow rate rangeop only saref:Measurementc primary air flow rate rangeop only saref:Measurementc has defrostdp only xsd:booleanc secondary air flow rate rangeop only saref:Measurementc secondary air flow rate rangeop only saref:Measurementc operation temperature rangeop only saref:Measurementc operation temperature rangeop only saref:Measurementc |
URI | https://saref.etsi.org/saref4bldg/Alarm |
---|---|
Description |
An alarm is a device that signals the existence of a condition or situation that is outside the boundaries of normal expectation or that activates such a device. Alarms include the provision of break glass buttons and manual pull boxes that are used to activate alarms. |
Super-classes |
Distribution control devicec |
URI | https://saref.etsi.org/saref4bldg/AudioVisualAppliance |
---|---|
Description |
An audio-visual appliance is a device that displays, captures, transmits, or receives audio or video. Audio-visual appliances may be fixed in place or may be able to be moved from one space to another. They may require an electrical supply that may be supplied either by an electrical circuit or provided from a local battery source. Audio-visual appliances may be connected to data circuits including specialist circuits for audio visual purposes only. |
Super-classes |
Flow terminalc |
Restrictions |
audio volumeop only saref:Measurementc media sourcedp only xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/Boiler |
---|---|
Description |
A boiler is a closed, pressure-rated vessel in which water or other fluid is heated using an energy source such as natural gas, heating oil, or electricity. The fluid in the vessel is then circulated out of the boiler for use in various processes or heating applications. |
Super-classes |
Energy conversion devicec |
Restrictions |
water inlet temperature rangeop only saref:Measurementc heat transfer surface areaop only saref:Measurementc outlet temperature rangeop only saref:Measurementc is water storage heaterdp only xsd:booleanc water storage capacityop only saref:Measurementc energy sourcedp only xsd:stringc nominal part load ratioop only saref:Measurementc water inlet temperature rangeop only saref:Measurementc operating modedp only xsd:stringc pressure ratingop only saref:Measurementc nominal energy consumptionop only saref:Measurementc outlet temperature rangeop only saref:Measurementc |
URI | https://saref.etsi.org/saref4bldg/Building |
---|---|
Description |
A building represents a structure that provides shelter for its occupants or contents and stands in one place. The building is also used to provide a basic element within the spatial structure hierarchy for the components of a building project (together with site, storey, and space). |
Restrictions |
has spaceop only Building spacec |
URI | https://saref.etsi.org/saref4bldg/BuildingDevice |
---|---|
Description |
A tangible object designed to accomplish a particular task in a building. |
Super-classes |
Building objectc saref:Devicec |
Sub-classes |
Distribution devicec Shading devicec |
URI | https://saref.etsi.org/saref4bldg/BuildingObject |
---|---|
Description |
An object in the building that can be controlled by devices, such as a door or a window that can be automatically opened or closed by an actuator. (Definition taken from SAREF 1.0) |
Super-classes |
Physical objectc |
Sub-classes |
Building devicec |
URI | https://saref.etsi.org/saref4bldg/BuildingSpace |
---|---|
Description |
An entity used to define the physical spaces of the building. A building space contains devices or building objects. |
Restrictions |
isSpaceOfop only (Buildingc or Building spacec) has spaceop only Building spacec containsop only Physical objectc |
URI | https://saref.etsi.org/saref4bldg/Burner |
---|---|
Description |
A burner is a device that converts fuel into heat through combustion. It includes gas, oil, and wood burners. |
Super-classes |
Energy conversion devicec |
Restrictions |
energy sourcedp only xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/Chiller |
---|---|
Description |
A chiller is a device used to remove heat from a liquid via a vapor-compression or absorption refrigeration cycle to cool a fluid, typically water or a mixture of water and glycol. The chilled fluid is then used to cool and dehumidify air in a building. |
Super-classes |
Energy conversion devicec |
Restrictions |
nominal efficiencyop only saref:Measurementc nominal evaporating temmperatureop only saref:Measurementc nominal condensing temperatureop only saref:Measurementc nominal capacityop only saref:Measurementc nominal power consumptionop only saref:Measurementc nominal heat rejection rateop only saref:Measurementc |
URI | https://saref.etsi.org/saref4bldg/Coil |
---|---|
Description |
A coil is a device used to provide heat transfer between non-mixing media. A common example is a cooling coil, which utilizes a finned coil in which circulates chilled water, antifreeze, or refrigerant that is used to remove heat from air moving across the surface of the coil. A coil may be used either for heating or cooling purposes by placing a series of tubes (the coil) carrying a heating or cooling fluid into an airstream. The coil may be constructed from tubes bundled in a serpentine form or from finned tubes that give a extended heat transfer surface. Coils may also be used for non-airflow cases such as embedded in a floor slab. |
Super-classes |
Energy conversion devicec |
Restrictions |
nominal sensible capacityop only saref:Measurementc nominal latent capacityop only saref:Measurementc air flow rate range minop only saref:Measurementc nominal uaop only saref:Measurementc placement typedp only xsd:stringc operation temperature rangeop only saref:Measurementc air flow rate range maxop only saref:Measurementc operation temperature rangeop only saref:Measurementc |
URI | https://saref.etsi.org/saref4bldg/CommunicationAppliance |
---|---|
Description |
A communications appliance transmits and receives electronic or digital information as data or sound. Communication appliances may be fixed in place or may be able to be moved from one space to another. Communication appliances require an electrical supply that may be supplied either by an electrical circuit or provided from a local battery source. |
Super-classes |
Flow terminalc |
URI | https://saref.etsi.org/saref4bldg/Compressor |
---|---|
Description |
A compressor is a device that compresses a fluid typically used in a refrigeration circuit. |
Super-classes |
Flow moving devicec |
Restrictions |
compressor speedop only saref:Measurementc maximum part load ratioop only saref:Measurementc nominal capacityop only saref:Measurementc power sourcedp only xsd:stringc ideal capacityop only saref:Measurementc impeller diameterop only saref:Measurementc ideal shaft powerop only saref:Measurementc has hot gas bypassdp only xsd:booleanc refrigerant classdp only xsd:stringc minimum part load ratioop only saref:Measurementc |
URI | https://saref.etsi.org/saref4bldg/Condenser |
---|---|
Description |
A condenser is a device that is used to dissipate heat, typically by condensing a substance such as a refrigerant from its gaseous to its liquid state. |
Super-classes |
Energy conversion devicec |
Restrictions |
refrigerant classdp only xsd:stringc internal water volumeop only saref:Measurementc internal refrigerant volumeop only saref:Measurementc nominal heat transfer coefficientop only saref:Measurementc nominal heat transfer areaop only saref:Measurementc external surface areaop only saref:Measurementc internal surface areaop only saref:Measurementc |
URI | https://saref.etsi.org/saref4bldg/Controller |
---|---|
Description |
A controller is a device that monitors inputs and controls outputs within a building automation system. A controller may be physical (having placement within a spatial structure) or logical (a software interface or aggregated within a programmable physical controller). |
Super-classes |
Distribution control devicec |
URI | https://saref.etsi.org/saref4bldg/CoolingTower |
---|---|
Description |
A cooling tower is a device which rejects heat to ambient air by circulating a fluid such as water through it to reduce its temperature by partial evaporation. |
Super-classes |
Energy conversion devicec |
Restrictions |
operation temperature rangeop only saref:Measurementc basin reserve volumeop only saref:Measurementc lift elevation differenceop only saref:Measurementc ambient design wet bulb temperatureop only saref:Measurementc spray typedp only xsd:stringc circuit typedp only xsd:stringc water requirementop only saref:Measurementc flow arrangementdp only xsd:stringc control strategydp only xsd:stringc ambient design dry bulb temperatureop only saref:Measurementc number of cellsdp only xsd:integerc operation temperature rangeop only saref:Measurementc capacity controldp only xsd:stringc nominal capacityop only saref:Measurementc |
URI | https://saref.etsi.org/saref4bldg/DistributionControlDevice |
---|---|
Description |
Represents devices of a building automation control system that are used to impart control over elements of a distribution system. (Definition adapated from http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcsharedbldgserviceelements/lexical/ifcdistributioncontrolelement.htm) |
Super-classes |
Distribution devicec |
Sub-classes |
Protective device tripping unitc Flow instrumentc Alarmc Sensorc Actuatorc Controllerc Unitary control elementc |
URI | https://saref.etsi.org/saref4bldg/DistributionDevice |
---|---|
Description |
Generalization of all devices that participate in a distribution system. (Definition adapated from http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcproductextension/lexical/ifcdistributionelement.htm) |
Super-classes |
Building devicec |
Sub-classes |
DistributionFlowDevicec Distribution control devicec |
URI | https://saref.etsi.org/saref4bldg/DistributionFlowDevice |
---|---|
Description |
Represents devices of a distribution system that facilitate the distribution of energy or matter, such as air, water or power. (Definition adapated from http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcsharedbldgserviceelements/lexical/ifcdistributionflowelement.htm) |
Super-classes |
Distribution devicec |
Sub-classes |
Flow treatment devicec Flow terminalc Flow storage devicec Flow controllerc Flow moving devicec Energy conversion devicec |
URI | https://saref.etsi.org/saref4bldg/DuctSilencer |
---|---|
Description |
A duct silencer is a device that is typically installed inside a duct distribution system for the purpose of reducing the noise levels from air movement, fan noise, etc. in the adjacent space or downstream of the duct silencer device. |
Super-classes |
Flow treatment devicec |
Restrictions |
weightop only saref:Measurementc air flow rate range maxop only saref:Measurementc has exterior insulationdp only xsd:booleanc air flow rate range minop only saref:Measurementc operation temperature rangeop only saref:Measurementc lengthop only saref:Measurementc maximum working pressureop only saref:Measurementc hydraulic diameterop only saref:Measurementc minimum working pressureop only saref:Measurementc operation temperature rangeop only saref:Measurementc |
URI | https://saref.etsi.org/saref4bldg/ElectricAppliance |
---|---|
Description |
An electric appliance is a device intended for consumer usage that is powered by electricity. Electric appliances may be fixed in place or may be able to be moved from one space to another. Electric appliances require an electrical supply that may be supplied either by an electrical circuit or provided from a local battery source. |
Super-classes |
Flow terminalc |
URI | https://saref.etsi.org/saref4bldg/ElectricFlowStorageDevice |
---|---|
Description |
An electric flow storage device is a device in which electrical energy is stored and from which energy may be progressively released. |
Super-classes |
Flow storage devicec |
Restrictions |
nominal supply voltageop only saref:Measurementc nominal frequencyop only saref:Measurementc nominal supply voltage offsetop only saref:Measurementc |
URI | https://saref.etsi.org/saref4bldg/ElectricGenerator |
---|---|
Description |
An electric generator is an engine that is a machine for converting mechanical energy into electrical energy. |
Super-classes |
Energy conversion devicec |
Restrictions |
maximum power outputop only saref:Measurementc electric generator efficiencyop only saref:Measurementc start current factorop only saref:Measurementc |
URI | https://saref.etsi.org/saref4bldg/ElectricMotor |
---|---|
Description |
An electric motor is an engine that is a machine for converting electrical energy into mechanical energy. |
Super-classes |
Energy conversion devicec |
Restrictions |
te timeop only saref:Measurementc starting timeop only saref:Measurementc has part windingdp only xsd:booleanc motor enclosure typedp only xsd:stringc frame sizedp only xsd:stringc start current factorop only saref:Measurementc electric motor efficiencyop only saref:Measurementc is guardeddp only xsd:booleanc maximum power outputop only saref:Measurementc locked rotor currentop only saref:Measurementc |
URI | https://saref.etsi.org/saref4bldg/ElectricTimeControl |
---|---|
Description |
An electric time control is a device that applies control to the provision or flow of electrical energy over time. |
Super-classes |
Flow controllerc |
URI | https://saref.etsi.org/saref4bldg/EnergyConversionDevice |
---|---|
Description |
The distribution flow element EnergyConversionDevice defines the occurrence of a device used to perform energy conversion or heat transfer and typically participates in a flow distribution system. |
Super-classes |
DistributionFlowDevicec |
Sub-classes |
Evaporatorc Electric generatorc Chillerc Heat exchangerc Condenserc Air to air heat recoveryc Boilerc Solar devicec Humidifierc Tube bundlec Coilc Evaporative coolerc Electric motorc Burnerc Cooling towerc Transformerc Enginec Cooled beamc |
URI | https://saref.etsi.org/saref4bldg/Engine |
---|---|
Description |
An engine is a device that converts fuel into mechanical energy through combustion. |
Super-classes |
Energy conversion devicec |
Restrictions |
energy sourcedp only xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/EvaporativeCooler |
---|---|
Description |
An evaporative cooler is a device that cools air by saturating it with water vapor. |
Super-classes |
Energy conversion devicec |
Restrictions |
operation temperature rangeop only saref:Measurementc operation temperature rangeop only saref:Measurementc heat exchange areaop only saref:Measurementc flow arrangementdp only xsd:stringc water requirementop only saref:Measurementc |
URI | https://saref.etsi.org/saref4bldg/Evaporator |
---|---|
Description |
An evaporator is a device in which a liquid refrigerent is vaporized and absorbs heat from the surrounding fluid. |
Super-classes |
Energy conversion devicec |
Restrictions |
evaporation medium typedp only xsd:stringc nominal heat transfer coefficientop only saref:Measurementc nominal heat transfer areaop only saref:Measurementc internal water volumeop only saref:Measurementc evaporation coolantdp only xsd:stringc external surface areaop only saref:Measurementc internal surface areaop only saref:Measurementc internal refrigerant volumeop only saref:Measurementc refrigerant classdp only xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/Fan |
---|---|
Description |
A fan is a device which imparts mechanical work on a gas. A typical usage of a fan is to induce airflow in a building services air distribution system. |
Super-classes |
Flow moving devicec |
Restrictions |
nominal air flow rateop only saref:Measurementc capacity control typedp only xsd:stringc operational riterialop only saref:Measurementc nominal total pressureop only saref:Measurementc operation temperature rangeop only saref:Measurementc nominal static pressureop only saref:Measurementc nominal power rateop only saref:Measurementc motor drive typedp only xsd:stringc operation temperature rangeop only saref:Measurementc nominal rotation speedop only saref:Measurementc |
URI | https://saref.etsi.org/saref4bldg/Filter |
---|---|
Description |
A filter is an apparatus used to remove particulate or gaseous matter from fluids and gases. |
Super-classes |
Flow treatment devicec |
Restrictions |
operation temperature rangeop only saref:Measurementc weightop only saref:Measurementc nominal pressure dropop only saref:Measurementc nominal media surface velocityop only saref:Measurementc nominal particle geometric standard deviationop only saref:Measurementc final resistanceop only saref:Measurementc operation temperature rangeop only saref:Measurementc initial resistanceop only saref:Measurementc nominal particle geometric mean diameterop only saref:Measurementc nominal flow rateop only saref:Measurementc fluid flow rate rangeop only saref:Measurementc nominal filter face velocityop only saref:Measurementc fluid flow rate rangeop only saref:Measurementc |
URI | https://saref.etsi.org/saref4bldg/FireSuppressionTerminal |
---|---|
Description |
A fire suppression terminal has the purpose of delivering a fluid (gas or liquid) that will suppress a fire. A fire suppression terminal provides for all forms of sprinkler, spreader and other form of terminal that is connected to a pipework system and intended to act in the role of suppressing a fire. |
Super-classes |
Flow terminalc |
URI | https://saref.etsi.org/saref4bldg/FlowController |
---|---|
Description |
The distribution flow element FlowController defines the occurrence of elements of a distribution system that are used to regulate flow through a distribution system. Examples include dampers, valves, switches, and relays. |
Super-classes |
DistributionFlowDevicec |
Sub-classes |
Switching devicec Flow meterc Damperc Protective devicec Valvec Electric time controlc |
URI | https://saref.etsi.org/saref4bldg/FlowInstrument |
---|---|
Description |
A flow instrument reads and displays the value of a particular property of a system at a point, or displays the difference in the value of a property between two points. Instrumentation is typically for the purpose of determining the value of the property at a point in time. It is not the purpose of an instrument to record or integrate the values over time (although they may be connected to recording devices that do perform such a function). This entity provides for all forms of mechanical flow instrument (thermometers, pressure gauges etc.) and electrical flow instruments (ammeters, voltmeters etc.) |
Super-classes |
Distribution control devicec |
URI | https://saref.etsi.org/saref4bldg/FlowMeter |
---|---|
Description |
A flow meter is a device that is used to measure the flow rate in a system. |
Super-classes |
Flow controllerc |
Restrictions |
read out typedp only xsd:stringc remote readingdp only xsd:booleanc |
URI | https://saref.etsi.org/saref4bldg/FlowMovingDevice |
---|---|
Description |
The distribution flow element FlowMovingDevice defines the occurrence of an apparatus used to distribute, circulate or perform conveyance of fluids, including liquids and gases (such as a pump or fan), and typically participates in a flow distribution system. |
Super-classes |
DistributionFlowDevicec |
Sub-classes |
Compressorc Fanc Pumpc |
URI | https://saref.etsi.org/saref4bldg/FlowStorageDevice |
---|---|
Description |
The distribution flow element FlowStorageDevice defines the occurrence of a device that participates in a distribution system and is used for temporary storage (such as a tank). |
Super-classes |
DistributionFlowDevicec |
Sub-classes |
Electric flow storage devicec Tankc |
URI | https://saref.etsi.org/saref4bldg/FlowTerminal |
---|---|
Description |
The distribution flow element FlowTerminal defines the occurrence of a permanently attached element that acts as a terminus or beginning of a distribution system (such as an air outlet, drain, water closet, or sink). A terminal is typically a point at which a system interfaces with an external environment. |
Super-classes |
DistributionFlowDevicec |
Sub-classes |
Communication appliancec Fire suppression terminalc Sanitary terminalc Lampc Audio visual appliancec Space heaterc Outletc Electric appliancec Medical devicec |
URI | https://saref.etsi.org/saref4bldg/FlowTreatmentDevice |
---|---|
Description |
The distribution flow element FlowTreatmentDevice defines the occurrence of a device typically used to remove unwanted matter from a fluid, either liquid or gas, and typically participates in a flow distribution system. |
Super-classes |
DistributionFlowDevicec |
Sub-classes |
Filterc Duct silencerc Interceptorc |
URI | https://saref.etsi.org/saref4bldg/HeatExchanger |
---|---|
Description |
A heat exchanger is a device used to provide heat transfer between non-mixing media such as plate and shell and tube heat exchangers. HeatExchanger is commonly used on water-side distribution systems to recover energy from a liquid to another liquid (typically water-based), whereas AirToAirHeatRecovery is commonly used on air-side distribution systems to recover energy from a gas to a gas (usually air). |
Super-classes |
Energy conversion devicec |
Restrictions |
arrangementdp only xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/Humidifier |
---|---|
Description |
A humidifier is a device that adds moisture into the air. |
Super-classes |
Energy conversion devicec |
Restrictions |
water requirementop only saref:Measurementc nominal moisture gainop only saref:Measurementc internal controldp only xsd:stringc nominal air flow rateop only saref:Measurementc weightop only saref:Measurementc applicationdp only xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/Interceptor |
---|---|
Description |
An interceptor is a device designed and installed in order to separate and retain deleterious, hazardous or undesirable matter while permitting normal sewage or liquids to discharge into a collection system by gravity. |
Super-classes |
Flow treatment devicec |
Restrictions |
nominal body lengthop only saref:Measurementc cover widthop only saref:Measurementc inlet connection sizeop only saref:Measurementc nominal body depthop only saref:Measurementc nominal body widthop only saref:Measurementc ventilating pipe sizeop only saref:Measurementc cover lengthop only saref:Measurementc outlet connection sizeop only saref:Measurementc |
URI | https://saref.etsi.org/saref4bldg/Lamp |
---|---|
Description |
A lamp is an artificial light source such as a light bulb or tube. |
Super-classes |
Flow terminalc |
Restrictions |
lamp maintenance factorop only saref:Measurementc contributed luminous fluxop only saref:Measurementc light emitter nominal powerop only saref:Measurementc color temperatureop only saref:Measurementc maximum spectrumop only saref:Measurementc lamp ballast typedp only xsd:stringc minimum spectrumop only saref:Measurementc color rendering indexdp only xsd:integerc color appearancedp only xsd:stringc lamp compensation typedp only xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/MedicalDevice |
---|---|
Description |
A medical device is attached to a medical piping system and operates upon medical gases to perform a specific function. Medical gases include medical air, medical vacuum, oxygen, carbon dioxide, nitrogen, and nitrous oxide. |
Super-classes |
Flow terminalc |
URI | https://saref.etsi.org/saref4bldg/Outlet |
---|---|
Description |
An outlet is a device installed at a point to receive one or more inserted plugs for electrical power or communications. Power outlets are commonly connected within a junction box; data outlets may be directly connected to a wall. For power outlets sharing the same circuit within a junction box, the ports should indicate the logical wiring relationship to the enclosing junction box, even though they may be physically connected to a cable going to another outlet, switch, or fixture. |
Super-classes |
Flow terminalc |
Restrictions |
is pluggable outletdp only xsd:booleanc number os socketsdp only xsd:integerc |
URI | https://saref.etsi.org/saref4bldg/PhysicalObject |
---|---|
Description |
Any Object that has a proper space region. (Definition extracted from DUL ontology) |
Restrictions |
is contained inop only (Building spacec or Physical objectc) containsop only Physical objectc |
Sub-classes |
saref:Devicec Building objectc |
URI | https://saref.etsi.org/saref4bldg/ProtectiveDevice |
---|---|
Description |
A protective device breaks an electrical circuit when a stated electric current that passes through it is exceeded. A protective device provides protection against electrical current only (not as a general protective device). It may be used to represent the complete set of elements including both the tripping unit and the breaking unit that provide the protection. This may be particularly useful at earlier stages of design where the approach to breaking the electrical supply may be determined but the method of tripping may not. Alternatively, this entity may be used to specifically represent the breaking unit alone (in which case the tripping unit will also be specifically identified). This entity is specific to dedicated protective devices and excludes electrical outlets that may have circuit protection. |
Super-classes |
Flow controllerc |
URI | https://saref.etsi.org/saref4bldg/ProtectiveDeviceTrippingUnit |
---|---|
Description |
A protective device tripping unit breaks an electrical circuit at a separate breaking unit when a stated electric current that passes through the unit is exceeded. |
Super-classes |
Distribution control devicec |
Restrictions |
standarddp only xsd:stringc limiting terminal sizeop only saref:Measurementc |
URI | https://saref.etsi.org/saref4bldg/Pump |
---|---|
Description |
A pump is a device which imparts mechanical work on fluids or slurries to move them through a channel or pipeline. A typical use of a pump is to circulate chilled water or heating hot water in a building services distribution system. |
Super-classes |
Flow moving devicec |
Restrictions |
operation temperature rangeop only saref:Measurementc net positive suction headop only saref:Measurementc pump flow rate rangeop only saref:Measurementc pump flow rate rangeop only saref:Measurementc nomminal rotation speedop only saref:Measurementc flow resistance rangeop only saref:Measurementc flow resistance rangeop only saref:Measurementc operation temperature rangeop only saref:Measurementc connection sizeop only saref:Measurementc |
URI | https://saref.etsi.org/saref4bldg/SanitaryTerminal |
---|---|
Description |
A sanitary terminal is a fixed appliance or terminal usually supplied with water and used for drinking, cleaning or foul water disposal or that is an item of equipment directly used with such an appliance or terminal. |
Super-classes |
Flow terminalc |
URI | https://saref.etsi.org/saref4bldg/Sensor |
---|---|
Description |
A sensor is a device that measures a physical quantity and converts it into a signal which can be read by an observer or by an instrument. |
Super-classes |
Distribution control devicec saref:Sensorc |
URI | https://saref.etsi.org/saref4bldg/ShadingDevice |
---|---|
Description |
Shading devices are purpose built devices to protect from the sunlight, from natural light, or screening them from view. Shading devices can form part of the facade or can be mounted inside the building, they can be fixed or operable. |
Super-classes |
Building devicec |
Restrictions |
mechanical operateddp only xsd:booleanc solar transmittanceop only saref:Measurementc visible light reflectanceop only saref:Measurementc roughnessdp only xsd:stringc thermal transmittanceop only saref:Measurementc visible light transmittanceop only saref:Measurementc solar reflectanceop only saref:Measurementc is externaldp only xsd:booleanc shading device typedp only xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/SolarDevice |
---|---|
Description |
A solar device converts solar radiation into other energy such as electric current or thermal energy. |
Super-classes |
Energy conversion devicec |
URI | https://saref.etsi.org/saref4bldg/SpaceHeater |
---|---|
Description |
Space heaters utilize a combination of radiation and/or natural convection using a heating source such as electricity, steam or hot water to heat a limited space or area. Examples of space heaters include radiators, convectors, baseboard and finned-tube heaters. UnitaryEquipment should be used for packaged units supporting a combination of heating, cooling, and/or dehumidification; Coil should be used for coil-based floor heating. |
Super-classes |
Flow terminalc |
Restrictions |
body massop only saref:Measurementc number of panelsdp only xsd:integerc number of sectionsdp only xsd:integerc thermal efficiencyop only saref:Measurementc output capacityop only saref:Measurementc heat transfer dimensiondp only xsd:stringc placement typedp only xsd:stringc heat transfer mediumdp only xsd:stringc thermal mass heat capacityop only saref:Measurementc energy sourcedp only xsd:stringc temperature classificationdp only xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/SwitchingDevice |
---|---|
Description |
A switch is used in a cable distribution system (electrical circuit) to control or modulate the flow of electricity. Switches include those used for electrical power, communications, audio-visual, or other distribution system types as determined by the available ports. |
Super-classes |
Flow controllerc |
Restrictions |
has lockdp only xsd:booleanc legenddp only xsd:stringc switch functiondp only xsd:stringc number of gangsdp only xsd:integerc is illuminateddp only xsd:booleanc |
URI | https://saref.etsi.org/saref4bldg/Tank |
---|---|
Description |
A tank is a vessel or container in which a fluid or gas is stored for later use. |
Super-classes |
Flow storage devicec |
Restrictions |
first curvature radiusop only saref:Measurementc number of sectionsdp only xsd:integerc access typedp only xsd:stringc storage typedp only xsd:stringc end shape typedp only xsd:stringc nominal length or diameterop only saref:Measurementc pattern typedp only xsd:stringc second curvature radiusop only saref:Measurementc operating weightop only saref:Measurementc nominal depthop only saref:Measurementc effective capacityop only saref:Measurementc nominal volumetric capacityop only saref:Measurementc nominal width or diameterop only saref:Measurementc |
URI | https://saref.etsi.org/saref4bldg/Transformer |
---|---|
Description |
A transformer is an inductive stationary device that transfers electrical energy from one circuit to another. Transformer is used to transform electric power; conversion of electric signals for other purposes is handled at other entities: Controller converts arbitrary signals, AudioVisualAppliance converts signals for audio or video streams, and CommunicationsAppliance converts signals for data or other communications usage. |
Super-classes |
Energy conversion devicec |
Restrictions |
transformer vector groupdp only xsd:stringc secondary voltageop only saref:Measurementc is neutral secondary terminal availabledp only xsd:booleanc primary voltageop only saref:Measurementc primary frequencyop only saref:Measurementc real impedance ratioop only saref:Measurementc secondary apparent powerop only saref:Measurementc maximum apparent powerop only saref:Measurementc secondary frequencyop only saref:Measurementc imaginary impedance ratioop only saref:Measurementc secondary currentop only saref:Measurementc secondary current typedp only xsd:stringc primary currentop only saref:Measurementc primary apparent powerop only saref:Measurementc is neutral primary terminal availabledp only xsd:booleanc |
URI | https://saref.etsi.org/saref4bldg/TransportElement |
---|---|
Description |
A transport element is a generalization of all transport related objects that move people, animals or goods within a building or building complex. The TransportElement defines the occurrence of a transport element. |
Super-classes |
saref:Devicec |
Restrictions |
capacity peopledp only xsd:positiveIntegerc fire exitdp only xsd:booleanc capacity weightop only saref:Measurementc |
URI | https://saref.etsi.org/saref4bldg/TubeBundle |
---|---|
Description |
A tube bundle is a device consisting of tubes and bundles of tubes used for heat transfer and contained typically within other energy conversion devices, such as a chiller or coil. |
Super-classes |
Energy conversion devicec |
Restrictions |
fouling factorop only saref:Measurementc number of rowsdp only xsd:integerc volumenop only saref:Measurementc outside diameterop only saref:Measurementc staggered row spacingop only saref:Measurementc in line row spacingop only saref:Measurementc nominal diameterop only saref:Measurementc horizontal spacingop only saref:Measurementc inside diameterop only saref:Measurementc vertical spacingop only saref:Measurementc thermal conductivityop only saref:Measurementc number of circuitsdp only xsd:integerc lengthop only saref:Measurementc has turbulatordp only xsd:booleanc |
URI | https://saref.etsi.org/saref4bldg/UnitaryControlElement |
---|---|
Description |
A unitary control element combines a number of control components into a single product, such as a thermostat or humidistat. A unitary control element provides a housing for an aggregation of control or electrical distribution elements that, in combination, perform a singular (unitary) purpose. Each item in the aggregation may have its own geometric representation and location. |
Super-classes |
Distribution control devicec |
URI | https://saref.etsi.org/saref4bldg/Valve |
---|---|
Description |
A valve is used in a building services piping distribution system to control or modulate the flow of the fluid. |
Super-classes |
Flow controllerc |
Restrictions |
valve mechanismdp only xsd:stringc sizeop only saref:Measurementc test pressureop only saref:Measurementc working pressureop only saref:Measurementc close off ratingop only saref:Measurementc flow coefficientop only saref:Measurementc valve operationdp only xsd:stringc valve patterndp only xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/VibrationIsolator |
---|---|
Description |
A vibration isolator is a device used to minimize the effects of vibration transmissibility in a building. |
Super-classes |
saref:Devicec |
Restrictions |
vibration transmissibilityop only saref:Measurementc maximum supported weightop only saref:Measurementc isolator compressibilityop only saref:Measurementc isolator static deflectionop only saref:Measurementc heightop only saref:Measurementc |
URI | http://www.w3.org/2003/01/geo/wgs84_pos#location |
---|---|
Is Defined By | http://www.w3.org/2003/01/geo/wgs84_pos# |
Description |
The relation between something and the point, or other geometrical thing in space, where it is. For example, the realtionship between a radio tower and a Point with a given lat and long. Or a relationship between a park and its outline as a closed arc of points, or a road and its location as a arc (a sequence of points). Clearly in practice there will be limit to the accuracy of any such statement, but one would expect an accuracy appropriate for the size of the object and uses such as mapping . |
URI | https://saref.etsi.org/core/isMeasuredIn |
---|---|
Is Defined By | https://saref.etsi.org/core/ |
Description |
A relation between a measurement and the unit of measure in which the measurement value is expressed. |
URI | https://saref.etsi.org/core/relatesToProperty |
---|---|
Is Defined By | https://saref.etsi.org/core/ |
Description |
A relation between a measurement and the property such measurement is about. |
URI | https://saref.etsi.org/saref4bldg/airFlowRateMax |
---|---|
Description |
Maximum allowable air flow rate. Usually measured in m3/s. |
URI | https://saref.etsi.org/saref4bldg/airFlowRateMin |
---|---|
Description |
Minimum allowable air flow rate. Usually measured in m3/s. |
URI | https://saref.etsi.org/saref4bldg/ambientDesignDryBulbTemperature |
---|---|
Description |
Ambient design dry bulb temperature used for selecting the cooling tower. Usually measured in degrees Kelvin (K). |
URI | https://saref.etsi.org/saref4bldg/ambientDesignWetBulbTemperature |
---|---|
Description |
Ambient design wet bulb temperature used for selecting the cooling tower. Usually measured in degrees Kelvin (K). |
URI | https://saref.etsi.org/saref4bldg/apparentPowerMax |
---|---|
Description |
Maximum apparent power/capacity in VA (volt ampere). Usually measured in Watts (W, J/s). |
URI | https://saref.etsi.org/saref4bldg/audioVolume |
---|---|
Description |
Indicates discrete audio volume levels and corresponding sound power offsets, if applicable. Missing values may be interpolated. Measured in watts. |
URI | https://saref.etsi.org/saref4bldg/basinReserveVolume |
---|---|
Description |
Volume between operating and overflow levels in cooling tower basin. Usually measured in cubic metre (m3). |
URI | https://saref.etsi.org/saref4bldg/bladeThickness |
---|---|
Description |
The thickness of the damper blade. Usually measured in millimeters (mm). |
URI | https://saref.etsi.org/saref4bldg/bodyMass |
---|---|
Description |
Overall body mass of the heater. Usually measured in kilograms (kg) or grams (g). |
URI | https://saref.etsi.org/saref4bldg/capacityWeight |
---|---|
Description |
Capacity of the transport element measured by weight. Usually measured in kilograms (kg) or grams (g). |
URI | https://saref.etsi.org/saref4bldg/closeOffRating |
---|---|
Description |
Close off rating. Usually measured in Pascals (Pa, N/m2). |
URI | https://saref.etsi.org/saref4bldg/coilLength |
---|---|
Description |
Length of coil. Usually measured in millimeters (mm). |
URI | https://saref.etsi.org/saref4bldg/coilWidth |
---|---|
Description |
Width of coil. Usually measured in millimeters (mm |
URI | https://saref.etsi.org/saref4bldg/colorTemperature |
---|---|
Description |
The color temperature of any source of radiation is defined as the temperature (in Kelvin) of a black-body or Planckian radiator whose radiation has the same chromaticity as the source of radiation. Often the values are only approximate color temperatures as the black-body radiator cannot emit radiation of every chromaticity value. The color temperatures of the commonest artificial light sources range from less than 3000K (warm white) to 4000K (intermediate) and over 5000K (daylight). Usually measured in degrees Kelvin (K). |
URI | https://saref.etsi.org/saref4bldg/compressorSpeed |
---|---|
Description |
Compressor speed. Usually measured in cycles/s. |
URI | https://saref.etsi.org/saref4bldg/connectionSize |
---|---|
Description |
The connection size of the to and from the pump. Usually measured in millimeters (mm). |
URI | https://saref.etsi.org/saref4bldg/contains |
---|---|
Description |
A relation between a physical space and the objects located in such space. |
Inverse properties | is contained inop |
URI | https://saref.etsi.org/saref4bldg/contributedLuminousFlux |
---|---|
Description |
Luminous flux is a photometric measure of radiant flux, i.e. the volume of light emitted from a light source. Luminous flux is measured either for the interior as a whole or for a part of the interior (partial luminous flux for a solid angle). All other photometric parameters are derivatives of luminous flux. Luminous flux is measured in lumens (lm). The luminous flux is given as a nominal value for each lamp. Usually measured in Lumen (lm, Candela Steradian). |
URI | https://saref.etsi.org/saref4bldg/coverLength |
---|---|
Description |
The length measured along the x-axis in the local coordinate system or the radius (in the case of a circular shape in plan) of the cover of the oil interceptor. Usually measured in millimeters (mm). |
URI | https://saref.etsi.org/saref4bldg/coverWidth |
---|---|
Description |
The length measured along the x-axis in the local coordinate system of the cover of the oil interceptor. Usually measured in millimeters (mm). |
URI | https://saref.etsi.org/saref4bldg/effectiveCapacity |
---|---|
Description |
The total effective or actual volumetric capacity of the tank. Usually measured in cubic metre (m3).B3 |
URI | https://saref.etsi.org/saref4bldg/electricGeneratorEfficiency |
---|---|
Description |
The ratio of output capacity to intake capacity. |
URI | https://saref.etsi.org/saref4bldg/electricMotorEfficiency |
---|---|
Description |
The ratio of output capacity to intake capacity. |
URI | https://saref.etsi.org/saref4bldg/externalSurfaceArea |
---|---|
Description |
External surface area (both primary and secondary area). Usually measured in square metre (m2). |
URI | https://saref.etsi.org/saref4bldg/faceArea |
---|---|
Description |
Face area open to the airstream. Usually measured in square metre (m2). |
URI | https://saref.etsi.org/saref4bldg/finalResistance |
---|---|
Description |
Filter fluid resistance when replacement is required (i.e., Pressure drop at the maximum air flowrate across the filter when the filter needs replacement per ASHRAE Standard 52.1). Usually measured in Pascals (Pa, N/m2). |
URI | https://saref.etsi.org/saref4bldg/firstCurvatureRadius |
---|---|
Description |
FirstCurvatureRadius should be defined as the base or left side radius of curvature value. Usually measured in millimeters (mm). |
URI | https://saref.etsi.org/saref4bldg/flowCoefficient |
---|---|
Description |
Flow coefficient (the quantity of fluid that passes through a fully open valve at unit pressure drop), typically expressed as the Kv or Cv value for the valve. |
URI | https://saref.etsi.org/saref4bldg/flowResistanceMax |
---|---|
Description |
Allowable range of frictional resistance against which the fluid is being pumped. Usually measured in Pascals (Pa, N/m2). |
URI | https://saref.etsi.org/saref4bldg/flowResistanceMin |
---|---|
Description |
Allowable range of frictional resistance against which the fluid is being pumped. Usually measured in Pascals (Pa, N/m2). |
URI | https://saref.etsi.org/saref4bldg/fluidFlowRateMax |
---|---|
Description |
Possible range of fluid flowrate that can be delivered. Usually measured in m3/s. |
URI | https://saref.etsi.org/saref4bldg/fluidFlowRateMin |
---|---|
Description |
Possible range of fluid flowrate that can be delivered. Usually measured in m3/s. |
URI | https://saref.etsi.org/saref4bldg/foulingFactor |
---|---|
Description |
Fouling factor of the tubes in the tube bundle. Usually measured in m2 Kelvin/Watt. |
URI | https://saref.etsi.org/saref4bldg/frameDepth |
---|---|
Description |
The length (or depth) of the damper frame. Usually measured in millimeters (mm). |
URI | https://saref.etsi.org/saref4bldg/frameThickness |
---|---|
Description |
The thickness of the damper frame material. Usually measured in millimeters (mm). |
URI | https://saref.etsi.org/saref4bldg/hasSpace |
---|---|
Description |
Relation between a building or a building space and the spaces it can be divided into. |
Inverse properties | isSpaceOfop |
URI | https://saref.etsi.org/saref4bldg/heatExchangeArea |
---|---|
Description |
Heat exchange area. Usually measured in square metre (m2). |
URI | https://saref.etsi.org/saref4bldg/heatTransferSurfaceArea |
---|---|
Description |
Total heat transfer area of the vessel. Usually measured in square metre (m2). |
URI | https://saref.etsi.org/saref4bldg/height |
---|---|
Description |
Height of the vibration isolator before tha application of load. Usually measured in millimeters (mm). |
URI | https://saref.etsi.org/saref4bldg/horizontalSpacing |
---|---|
Description |
Horizontal spacing between tubes in the tube bundle. Usually measured in millimeters (mm). |
URI | https://saref.etsi.org/saref4bldg/hydraulicDiameter |
---|---|
Description |
Hydraulic diameter. Usually measured in millimeters (mm). |
URI | https://saref.etsi.org/saref4bldg/idealCapacity |
---|---|
Description |
Compressor capacity under ideal conditions. Usually measured in Watts (W, J/s). |
URI | https://saref.etsi.org/saref4bldg/idealShaftPower |
---|---|
Description |
Compressor shaft power under ideal conditions. Usually measured in Watts (W, J/s). |
URI | https://saref.etsi.org/saref4bldg/imaginaryImpedanceRatio |
---|---|
Description |
The ratio between the imaginary part of the zero sequence impedance and the imaginary part of the positive impedance (i.e. imaginary part of the short-circuit voltage) of the transformer. Used for three-phase transformer which includes a N-conductor. |
URI | https://saref.etsi.org/saref4bldg/impellerDiameter |
---|---|
Description |
Diameter of compressor impeller - used to scale performance of geometrically similar compressors. Usually measured in millimeters (mm). |
URI | https://saref.etsi.org/saref4bldg/inLineRowSpacing |
---|---|
Description |
In-line tube row spacing. Usually measured in millimeters (mm). |
URI | https://saref.etsi.org/saref4bldg/initialResistance |
---|---|
Description |
Initial new filter fluid resistance (i.e., pressure drop at the maximum air flowrate across the filter when the filter is new per ASHRAE Standard 52.1). Usually measured in Pascals (Pa, N/m2). |
URI | https://saref.etsi.org/saref4bldg/inletConnectionSize |
---|---|
Description |
Size of the inlet connection. Usually measured in millimeters (mm). |
URI | https://saref.etsi.org/saref4bldg/insideDiameter |
---|---|
Description |
Actual inner diameter of the tube in the tube bundle. Usually measured in millimeters (mm). |
URI | https://saref.etsi.org/saref4bldg/internalRefrigerantVolume |
---|---|
Description |
Internal volume of evaporator (refrigerant side). Usually measured in cubic metre (m3). |
URI | https://saref.etsi.org/saref4bldg/internalSurfaceArea |
---|---|
Description |
Internal surface area. Usually measured in square metre (m2). |
URI | https://saref.etsi.org/saref4bldg/internalWaterVolume |
---|---|
Description |
Internal volume of evaporator (water side). Usually measured in cubic metre (m3). |
URI | https://saref.etsi.org/saref4bldg/isContainedIn |
---|---|
Description |
A relation between an object and the physical space in which it is located. |
URI | https://saref.etsi.org/saref4bldg/isSpaceOf |
---|---|
Description |
Relation between a building space and the building or building space it belongs to. |
URI | https://saref.etsi.org/saref4bldg/isolatorCompressibility |
---|---|
Description |
The compressibility of the vibration isolator. |
URI | https://saref.etsi.org/saref4bldg/isolatorStaticDeflection |
---|---|
Description |
Static deflection of the vibration isolator. Usually measured in millimeters (mm). |
URI | https://saref.etsi.org/saref4bldg/lampMaintenanceFactor |
---|---|
Description |
Non recoverable losses of luminous flux of a lamp due to lamp depreciation i.e. the decreasing of light output of a luminaire due to aging and dirt. |
URI | https://saref.etsi.org/saref4bldg/leakageFullyClosed |
---|---|
Description |
Leakage when fully closed. Usually measured in m3/s. |
URI | https://saref.etsi.org/saref4bldg/length |
---|---|
Description |
The finished length of the device. Usually measured in millimeters (mm). |
URI | https://saref.etsi.org/saref4bldg/liftElevationDifference |
---|---|
Description |
Elevation difference between cooling tower sump and the top of the tower. Usually measured in millimeters (mm). |
URI | https://saref.etsi.org/saref4bldg/lightEmitterNominalPower |
---|---|
Description |
Light emitter nominal power. Usually measured in Watts (W, J/s). |
URI | https://saref.etsi.org/saref4bldg/limitingTerminalSize |
---|---|
Description |
The maximum terminal size capacity of the device. Usually measured in square metre (m2). |
URI | https://saref.etsi.org/saref4bldg/lockedRotorCurrent |
---|---|
Description |
Input current when a motor armature is energized but not rotating. Usually measured in Ampere (A). |
URI | https://saref.etsi.org/saref4bldg/netPositiveSuctionHead |
---|---|
Description |
Minimum liquid pressure at the pump inlet to prevent cavitation. Usually measured in Pascals (Pa, N/m2). |
URI | https://saref.etsi.org/saref4bldg/nominalAirFlowRate |
---|---|
Description |
Nominal rate of air flow. Usually measured in m3/s. |
URI | https://saref.etsi.org/saref4bldg/nominalBodyDepth |
---|---|
Description |
Nominal or quoted =length, measured along the z-axis of the local coordinate system of the object, of the body of the object. Usually measured in millimeters (mm). |
URI | https://saref.etsi.org/saref4bldg/nominalBodyLength |
---|---|
Description |
Nominal or quoted length, measured along the x-axis of the local coordinate system of the object, of the body of the object. Usually measured in millimeters (mm). |
URI | https://saref.etsi.org/saref4bldg/nominalBodyWidth |
---|---|
Description |
Nominal or quoted length, measured along the y-axis of the local coordinate system of the object, of the body of the object. Usually measured in millimeters (mm). |
URI | https://saref.etsi.org/saref4bldg/nominalCapacity |
---|---|
Description |
Nominal capacity. Usually measured in Watts (W, J/s). |
URI | https://saref.etsi.org/saref4bldg/nominalCondensingTemperature |
---|---|
Description |
Chiller condensing temperature. Usually measured in degrees Kelvin (K). |
URI | https://saref.etsi.org/saref4bldg/nominalCoolingCapacity |
---|---|
Description |
Nominal cooling capacity. Usually measured in Watts (W, J/s). |
URI | https://saref.etsi.org/saref4bldg/nominalDepth |
---|---|
Description |
The nominal depth of the tank. Note: Not required for a horizontal cylindrical tank. Usually measured in millimeters (mm). |
URI | https://saref.etsi.org/saref4bldg/nominalDiameter |
---|---|
Description |
Nominal diameter or width of the tubes in the tube bundle. Usually measured in millimeters (mm). |
URI | https://saref.etsi.org/saref4bldg/nominalEfficiency |
---|---|
Description |
Nominal chiller efficiency under nominal conditions. |
URI | https://saref.etsi.org/saref4bldg/nominalEnergyConsumption |
---|---|
Description |
Nominal fuel consumption rate required to produce the total boiler heat output. Usually measured in Watts (W, J/s). |
URI | https://saref.etsi.org/saref4bldg/nominalEvaporatingTemmperature |
---|---|
Description |
Chiller evaporating temperature.Usually measured in degrees Kelvin (K). |
URI | https://saref.etsi.org/saref4bldg/nominalFilterFaceVelocity |
---|---|
Description |
Filter face velocity. Usually measured in m/s. |
URI | https://saref.etsi.org/saref4bldg/nominalFlowRate |
---|---|
Description |
Nominal fluid flow rate through the filter. Usually measured in m3/s. |
URI | https://saref.etsi.org/saref4bldg/nominalFrequency |
---|---|
Description |
The nominal frequency of the supply. Usually measured in cycles/s or Hertz (Hz). |
URI | https://saref.etsi.org/saref4bldg/nominalHeatRejectionRate |
---|---|
Description |
Sum of the refrigeration effect and the heat equivalent of the power input to the compressor. Usually measured in Watts (W, J/s). |
URI | https://saref.etsi.org/saref4bldg/nominalHeatTransferArea |
---|---|
Description |
Nominal heat transfer surface area associated with nominal overall heat transfer coefficient. Usually measured in square metre (m2). |
URI | https://saref.etsi.org/saref4bldg/nominalHeatTransferCoefficient |
---|---|
Description |
Nominal overall heat transfer coefficient associated with nominal heat transfer area. Usually measured in Watts/m2 Kelvin. |
URI | https://saref.etsi.org/saref4bldg/nominalHeatingCapacity |
---|---|
Description |
Nominal heating capacity. Usually measured in Watts (W, J/s). |
URI | https://saref.etsi.org/saref4bldg/nominalLatentCapacity |
---|---|
Description |
Nominal latent capacity. Usually measured in Watts (W, J/s). |
URI | https://saref.etsi.org/saref4bldg/nominalLengthOrDiameter |
---|---|
Description |
The nominal length or, in the case of a vertical cylindrical tank, the nominal diameter of the tank. Usually measured in millimeters (mm). |
URI | https://saref.etsi.org/saref4bldg/nominalMediaSurfaceVelocity |
---|---|
Description |
Average fluid velocity at the media surface. Usually measured in m/s. |
URI | https://saref.etsi.org/saref4bldg/nominalMoistureGain |
---|---|
Description |
Nominal rate of water vapor added into the airstream. Usually measured in kg/s. |
URI | https://saref.etsi.org/saref4bldg/nominalPartLoadRatio |
---|---|
Description |
Allowable part load ratio range. |
URI | https://saref.etsi.org/saref4bldg/nominalParticleGeometricMeanDiameter |
---|---|
Description |
Particle geometric mean diameter associated with nominal efficiency. Usually measured in millimeters (mm). |
URI | https://saref.etsi.org/saref4bldg/nominalParticleGeometricStandardDeviation |
---|---|
Description |
Particle geometric standard deviation associated with nominal efficiency. |
URI | https://saref.etsi.org/saref4bldg/nominalPowerConsumption |
---|---|
Description |
Nominal total power consumption. Usually measured in Watts (W, J/s). |
URI | https://saref.etsi.org/saref4bldg/nominalPowerRate |
---|---|
Description |
Nominal fan power rate.Usually measured in Watts (W, J/s). |
URI | https://saref.etsi.org/saref4bldg/nominalPressureDrop |
---|---|
Description |
Total pressure drop across the filter. Usually measured in Pascals (Pa, N/m2). |
URI | https://saref.etsi.org/saref4bldg/nominalReturnWaterTemperatureCooling |
---|---|
Description |
Nominal return water temperature (refers to nominal cooling capacity). Usually measured in degrees Kelvin (K). |
URI | https://saref.etsi.org/saref4bldg/nominalReturnWaterTemperatureHeating |
---|---|
Description |
Nominal return water temperature (refers to nominal heating capacity). Usually measured in degrees Kelvin (K). |
URI | https://saref.etsi.org/saref4bldg/nominalRotationSpeed |
---|---|
Description |
Nominal fan wheel speed. Usually measured in cycles/s. |
URI | https://saref.etsi.org/saref4bldg/nominalSensibleCapacity |
---|---|
Description |
Nominal sensible capacity. Usually measured in Watts (W, J/s). |
URI | https://saref.etsi.org/saref4bldg/nominalSorroundingHumidityCooling |
---|---|
Description |
Nominal surrounding humidity (refers to nominal cooling capacity). Usually measured in degrees Kelvin (K). |
URI | https://saref.etsi.org/saref4bldg/nominalSorroundingTemperatureCooling |
---|---|
Description |
Nominal surrounding temperature (refers to nominal cooling capacity). Usually measured in degrees Kelvin (K). |
URI | https://saref.etsi.org/saref4bldg/nominalSorroundingTemperatureHeating |
---|---|
Description |
Nominal surrounding temperature (refers to nominal heating capacity). Usually measured in degrees Kelvin (K). |
URI | https://saref.etsi.org/saref4bldg/nominalStaticPressure |
---|---|
Description |
The static pressure within the air stream that the fan must overcome to insure designed circulation of air. Usually measured in Pascals (Pa, N/m2). |
URI | https://saref.etsi.org/saref4bldg/nominalSupplyVoltage |
---|---|
Description |
The nominal voltage of the supply. Usually measured in Volts (V, W/A). |
URI | https://saref.etsi.org/saref4bldg/nominalSupplyVoltageMax |
---|---|
Description |
The maximum and minimum allowed voltage of the supply e.g. boundaries of 380V/440V may be applied for a nominal voltage of 400V. |
URI | https://saref.etsi.org/saref4bldg/nominalSupplyVoltageMin |
---|---|
Description |
The maximum and minimum allowed voltage of the supply e.g. boundaries of 380V/440V may be applied for a nominal voltage of 400V. |
URI | https://saref.etsi.org/saref4bldg/nominalSupplyWaterTemperatureCooling |
---|---|
Description |
Nominal supply water temperature (refers to nominal cooling capacity). Usually measured in degrees Kelvin (K). |
URI | https://saref.etsi.org/saref4bldg/nominalSupplyWaterTemperatureHeating |
---|---|
Description |
Nominal supply water temperature (refers to nominal heating capacity). Usually measured in degrees Kelvin (K). |
URI | https://saref.etsi.org/saref4bldg/nominalTotalPressure |
---|---|
Description |
Nominal total pressure rise across the fan. Usually measured in Pascals (Pa, N/m2). |
URI | https://saref.etsi.org/saref4bldg/nominalVolumetricCapacity |
---|---|
Description |
The total nominal or design volumetric capacity of the tank. Usually measured in cubic metre (m3). |
URI | https://saref.etsi.org/saref4bldg/nominalWaterFlowCooling |
---|---|
Description |
Nominal water flow (refers to nominal cooling capacity). Usually measured in m3/s. |
URI | https://saref.etsi.org/saref4bldg/nominalWaterFlowHeating |
---|---|
Description |
Nominal water flow (refers to nominal heating capacity). Usually measured in m3/s. |
URI | https://saref.etsi.org/saref4bldg/nominalWidthOrDiameter |
---|---|
Description |
The nominal width or, in the case of a horizontal cylindrical tank, the nominal diameter of the tank. Note: Not required for a vertical cylindrical tank. Usually measured in millimeters (mm). |
URI | https://saref.etsi.org/saref4bldg/nomminalRotationSpeed |
---|---|
Description |
Pump rotational speed under nominal conditions. Usually measured in cycles/s. |
URI | https://saref.etsi.org/saref4bldg/openPressureDrop |
---|---|
Description |
Total pressure drop across damper. Usually measured in Pascals (Pa, N/m2). |
URI | https://saref.etsi.org/saref4bldg/operatingWeight |
---|---|
Description |
Operating weight of the tank including all of its contents. Usually measured in kilograms (kg) or grams (g). |
URI | https://saref.etsi.org/saref4bldg/operationTemperatureMax |
---|---|
Description |
Allowable operation ambient (air, fluid) temperature range. Usually measured in degrees Kelvin (K). |
URI | https://saref.etsi.org/saref4bldg/operationTemperatureMin |
---|---|
Description |
Allowable operation ambient (air, fluid) temperature range. Usually measured in degrees Kelvin (K). |
URI | https://saref.etsi.org/saref4bldg/operationalRiterial |
---|---|
Description |
Time of operation at maximum operational ambient air temperature. Measured in seconds (s) or days (d) or other units of time. |
URI | https://saref.etsi.org/saref4bldg/outletConnectionSize |
---|---|
Description |
Size of the outlet connection. Usually measured in millimeters (mm). |
URI | https://saref.etsi.org/saref4bldg/outletTemperatureMax |
---|---|
Description |
Allowable outlet temperature of either the water or the steam. Usually measured in degrees Kelvin (K). |
URI | https://saref.etsi.org/saref4bldg/outletTemperatureMin |
---|---|
Description |
Allowable outlet temperature of either the water or the steam. Usually measured in degrees Kelvin (K). |
URI | https://saref.etsi.org/saref4bldg/outputCapacity |
---|---|
Description |
Total nominal heat output as listed by the manufacturer. Usually measured in Watts (W, J/s). |
URI | https://saref.etsi.org/saref4bldg/outsideDiameter |
---|---|
Description |
Actual outside diameter of the tube in the tube bundle. Usually measured in millimeters (mm). |
URI | https://saref.etsi.org/saref4bldg/partLoadRatioMax |
---|---|
Description |
Maximum part load ratio as a fraction of nominal capacity. |
URI | https://saref.etsi.org/saref4bldg/partLoadRatioMin |
---|---|
Description |
Minimum part load ratio as a fraction of nominal capacity. |
URI | https://saref.etsi.org/saref4bldg/powerOutputMax |
---|---|
Description |
The maximum output power rating of the engine. Usually measured in Watts (W, J/s). |
URI | https://saref.etsi.org/saref4bldg/pressureRating |
---|---|
Description |
Nominal pressure rating of the boiler as rated by the agency having jurisdiction. Usually measured in Pascals (Pa, N/m2). |
URI | https://saref.etsi.org/saref4bldg/primaryAirFlowRateMax |
---|---|
Description |
Maximum primary airflow that can be delivered. Usually measured in m3/s. |
URI | https://saref.etsi.org/saref4bldg/primaryAirFlowRateMin |
---|---|
Description |
Minimum primary airflow that can be delivered. Usually measured in m3/s. |
URI | https://saref.etsi.org/saref4bldg/primaryApparentPower |
---|---|
Description |
The power in VA (volt ampere) that has been transformed and that runs into the transformer on the primary side. Usually measured in Watts (W, J/s). |
URI | https://saref.etsi.org/saref4bldg/primaryCurrent |
---|---|
Description |
The current that is going to be transformed and that runs into the transformer on the primary side. Usually measured in Ampere (A). |
URI | https://saref.etsi.org/saref4bldg/primaryFrequency |
---|---|
Description |
The frequency that is going to be transformed and that runs into the transformer on the primary side. Usually measured in cycles/s or Hertz (Hz). |
URI | https://saref.etsi.org/saref4bldg/primaryVoltage |
---|---|
Description |
The voltage that is going to be transformed and that runs into the transformer on the primary side. Usually measured in Volts (V, W/A). |
URI | https://saref.etsi.org/saref4bldg/pumpFlowRateMax |
---|---|
Description |
Allowable range of volume of fluid being pumped against the resistance specified. Usually measured in kg/s. |
URI | https://saref.etsi.org/saref4bldg/pumpFlowRateMin |
---|---|
Description |
Allowable range of volume of fluid being pumped against the resistance specified. Usually measured in kg/s. |
URI | https://saref.etsi.org/saref4bldg/realImpedanceRatio |
---|---|
Description |
The ratio between the real part of the zero sequence impedance and the real part of the positive impedance (i.e. real part of the short-circuit voltage) of the transformer. Used for three-phase transformer which includes a N-conductor. |
URI | https://saref.etsi.org/saref4bldg/secondCurvatureRadius |
---|---|
Description |
SecondCurvatureRadius should be defined as the top or right side radius of curvature value. Usually measured in millimeters (mm). |
URI | https://saref.etsi.org/saref4bldg/secondaryAirFlowRateMax |
---|---|
Description |
Maximum secondary airflow that can be delivered. Usually measured in Pascals (Pa, N/m2). |
URI | https://saref.etsi.org/saref4bldg/secondaryAirFlowRateMin |
---|---|
Description |
Maximum secondary airflow that can be delivered. Usually measured in Pascals (Pa, N/m2). |
URI | https://saref.etsi.org/saref4bldg/secondaryApparentPower |
---|---|
Description |
The power in VA (volt ampere) that has been transformed and is running out of the transformer on the secondary side. Usually measured in Watts (W, J/s). |
URI | https://saref.etsi.org/saref4bldg/secondaryCurrent |
---|---|
Description |
The current that has been transformed and is running out of the transformer on the secondary side. Usually measured in Ampere (A). |
URI | https://saref.etsi.org/saref4bldg/secondaryFrequency |
---|---|
Description |
The frequency that has been transformed and is running out of the transformer on the secondary side. Usually measured in cycles/s or Hertz (Hz). |
URI | https://saref.etsi.org/saref4bldg/secondaryVoltage |
---|---|
Description |
The voltage that has been transformed and is running out of the transformer on the secondary side. Usually measured in Volts (V, W/A). |
URI | https://saref.etsi.org/saref4bldg/shortCircuitVoltage |
---|---|
Description |
A complex number that specifies the real and imaginary parts of the short-circuit voltage at rated current of a transformer given in %. |
URI | https://saref.etsi.org/saref4bldg/size |
---|---|
Description |
The size of the connection to the valve (or to each connection for faucets, mixing valves, etc.). Usually measured in millimeters (mm). |
URI | https://saref.etsi.org/saref4bldg/solarReflectance |
---|---|
Description |
(Rsol): The ratio of incident solar radiation that is reflected by a shading system (also named _e). Note the following equation Asol + Rsol + Tsol = 1 |
URI | https://saref.etsi.org/saref4bldg/solarTransmittance |
---|---|
Description |
(Tsol) The ratio of incident solar radiation that directly passes through a shading system (also named _e). Note the following equation Asol + Rsol + Tsol = 1 |
URI | https://saref.etsi.org/saref4bldg/spectrumMax |
---|---|
Description |
The spectrum of radiation describes its composition with regard to wavelength. Light, for example, as the portion of electromagnetic radiation that is visible to the human eye, is radiation with wavelengths in the range of approx. 380 to 780 nm (1 nm = 10 m). The corresponding range of colours varies from violet to indigo, blue, green, yellow, orange, and red. These colours form a continuous spectrum, in which the various spectral sectors merge into each other. |
URI | https://saref.etsi.org/saref4bldg/spectrumMin |
---|---|
Description |
The spectrum of radiation describes its composition with regard to wavelength. Light, for example, as the portion of electromagnetic radiation that is visible to the human eye, is radiation with wavelengths in the range of approx. 380 to 780 nm (1 nm = 10 m). The corresponding range of colours varies from violet to indigo, blue, green, yellow, orange, and red. These colours form a continuous spectrum, in which the various spectral sectors merge into each other. |
URI | https://saref.etsi.org/saref4bldg/staggeredRowSpacing |
---|---|
Description |
Staggered tube row spacing. Usually measured in millimeters (mm). |
URI | https://saref.etsi.org/saref4bldg/startCurrentFactor |
---|---|
Description |
IEC. Start current factor defines how large the peek starting current will become on the engine. StartCurrentFactor is multiplied to NominalCurrent and we get the start current. |
URI | https://saref.etsi.org/saref4bldg/startingTime |
---|---|
Description |
The time (in s) needed for the motor to reach its rated speed with its driven equipment attached, starting from standstill and at the nominal voltage applied at its terminals. |
URI | https://saref.etsi.org/saref4bldg/supportedWeightMax |
---|---|
Description |
The maximum weight that can be carried by the vibration isolator. Usually measured in kilograms (kg) or grams (g). |
URI | https://saref.etsi.org/saref4bldg/teTime |
---|---|
Description |
The maximum time (in s) at which the motor could run with locked rotor when the motor is used in an EX-environment. The time indicates that a protective device should trip before this time when the starting current of the motor is slowing through the device. |
URI | https://saref.etsi.org/saref4bldg/temperatureRating |
---|---|
Description |
Temperature rating. Usually measured in degrees Kelvin (K). |
URI | https://saref.etsi.org/saref4bldg/testPressure |
---|---|
Description |
The maximum pressure to which the valve has been subjected under test. Usually measured in Pascals (Pa, N/m2). |
URI | https://saref.etsi.org/saref4bldg/thermalConductivity |
---|---|
Description |
Fouling factor of the tubes in the tube bundle. Usually measured in m2 Kelvin/Watt. |
URI | https://saref.etsi.org/saref4bldg/thermalEfficiency |
---|---|
Description |
Overall Thermal Efficiency is defined as gross energy output of the heat transfer device divided by the energy input. |
URI | https://saref.etsi.org/saref4bldg/thermalMassHeatCapacity |
---|---|
Description |
Product of component mass and specific heat. |
URI | https://saref.etsi.org/saref4bldg/thermalTransmittance |
---|---|
Description |
Rate at which energy is transmitted through a body. Usually measured in Watts/m2 Kelvin. |
URI | https://saref.etsi.org/saref4bldg/ventilatingPipeSize |
---|---|
Description |
Size of the ventilating pipe(s). Usually measured in millimeters (mm). |
URI | https://saref.etsi.org/saref4bldg/verticalSpacing |
---|---|
Description |
Vertical spacing between tubes in the tube bundle.Usually measured in millimeters (mm). |
URI | https://saref.etsi.org/saref4bldg/vibrationTransmissibility |
---|---|
Description |
The vibration transmissibility percentage. |
URI | https://saref.etsi.org/saref4bldg/visibleLightReflectance |
---|---|
Description |
Fraction of the visible light that is reflected by the glazing at normal incidence. It is a value without unit. |
URI | https://saref.etsi.org/saref4bldg/visibleLightTransmittance |
---|---|
Description |
Fraction of the visible light that passes the shading system at normal incidence. It is a value without unit. |
URI | https://saref.etsi.org/saref4bldg/volumen |
---|---|
Description |
Total volume of fluid in the tubes and their headers. Usually measured in cubic metre (m3). |
URI | https://saref.etsi.org/saref4bldg/waterInletTemperatureMax |
---|---|
Description |
Allowable water inlet temperature range. Usually measured in degrees Kelvin (K). |
URI | https://saref.etsi.org/saref4bldg/waterInletTemperatureMin |
---|---|
Description |
Allowable water inlet temperature range. Usually measured in degrees Kelvin (K). |
URI | https://saref.etsi.org/saref4bldg/waterPressureMax |
---|---|
Description |
Allowable water circuit working pressure range. Usually measured in Pascals (Pa, N/m2). |
URI | https://saref.etsi.org/saref4bldg/waterPressureMin |
---|---|
Description |
Allowable water circuit working pressure range. Usually measured in Pascals (Pa, N/m2). |
URI | https://saref.etsi.org/saref4bldg/waterRequirement |
---|---|
Description |
Make-up water requirement. Usually measured in m3/s. |
URI | https://saref.etsi.org/saref4bldg/waterStorageCapacity |
---|---|
Description |
Water storage capacity. Usually measured in cubic metre (m3). |
URI | https://saref.etsi.org/saref4bldg/weight |
---|---|
Description |
The weight of the device. Usually measured in kilograms (kg) or grams (g). |
URI | https://saref.etsi.org/saref4bldg/workingPressure |
---|---|
Description |
The normally expected maximum working pressure of the valve. Usually measured in Pascals (Pa, N/m2). |
URI | https://saref.etsi.org/core/hasTimestamp |
---|---|
Is Defined By | https://saref.etsi.org/core/ |
Description |
A relationship stating the timestamp of an entity (e.g. a measurement). |
Range(s) | xsd:dateTimec |
URI | https://saref.etsi.org/core/hasValue |
---|---|
Is Defined By | https://saref.etsi.org/core/ |
Description |
A relationship defining the value of a certain property, e.g., energy or power |
URI | https://saref.etsi.org/saref4bldg/accessType |
---|---|
Description |
Defines the types of access (or cover) to a tank that may be specified. Note that covers are generally specified for rectangular tanks. For cylindrical tanks, access will normally be via a manhole. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/application |
---|---|
Description |
Humidifier application. Fixed: Humidifier installed in a ducted flow distribution system. Portable: Humidifier is not installed in a ducted flow distribution system. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/arrangement |
---|---|
Description |
Defines the basic flow arrangements for the heat exchanger: COUNTERFLOW: Counterflow heat exchanger arrangement. CROSSFLOW: Crossflow heat exchanger arrangement. PARALLELFLOW: Parallel flow heat exchanger arrangement. MULTIPASS: Multipass flow heat exchanger arrangement. OTHER: Other type of heat exchanger flow arrangement not defined above. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/bladeAction |
---|---|
Description |
Blade action. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/bladeEdge |
---|---|
Description |
Blade edge. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/bladeShape |
---|---|
Description |
Blade shape. Flat means triple V-groove. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/capacityControl |
---|---|
Description |
FanCycling: Fan is cycled on and off to control duty. TwoSpeedFan: Fan is switched between low and high speed to control duty. VariableSpeedFan: Fan speed is varied to control duty. DampersControl: Dampers modulate the air flow to control duty. BypassValveControl: Bypass valve modulates the water flow to control duty. MultipleSeriesPumps: Turn on/off multiple series pump to control duty. TwoSpeedPump: Switch between high/low pump speed to control duty. VariableSpeedPump: vary pump speed to control duty. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/capacityControlType |
---|---|
Description |
InletVane: Control by adjusting inlet vane. VariableSpeedDrive: Control by variable speed drive. BladePitchAngle: Control by adjusting blade pitch angle. TwoSpeed: Control by switch between high and low speed. DischargeDamper: Control by modulating discharge damper. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/capacityPeople |
---|---|
Description |
Capacity of the transportation element measured in numbers of person. |
Range(s) | xsd:nonNegativeIntegerc |
URI | https://saref.etsi.org/saref4bldg/circuitType |
---|---|
Description |
OpenCircuit: Exposes water directly to the cooling atmosphere. CloseCircuit: The fluid is separated from the atmosphere by a heat exchanger. Wet: The air stream or the heat exchange surface is evaporatively cooled. Dry: No evaporation into the air stream. DryWet: A combination of a dry tower and a wet tower. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/colorAppearance |
---|---|
Description |
In both the DIN and CIE standards, artificial light sources are classified in terms of their color appearance. To the human eye they all appear to be white the difference can only be detected by direct comparison. Visual performance is not directly affected by differences in color appearance. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/colorRenderingIndex |
---|---|
Description |
The CRI indicates how well a light source renders eight standard colors compared to perfect reference lamp with the same color temperature. The CRI scale ranges from 1 to 100, with 100 representing perfect rendering properties. |
Range(s) | xsd:integerc |
URI | https://saref.etsi.org/saref4bldg/controlStrategy |
---|---|
Description |
FixedExitingWaterTemp: The capacity is controlled to maintain a fixed exiting water temperature. WetBulbTempReset: The set-point is reset based on the wet-bulb temperature. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/endShapeType |
---|---|
Description |
Defines the types of end shapes that can be used for preformed tanks. The convention for reading these enumerated values is that for a vertical cylinder, the first value is the base and the second is the top for a horizontal cylinder, the order of reading should be left to right. For a speherical tank, the value UNSET should be used.B5 |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/energySource |
---|---|
Description |
The source of energy. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/evaporationCoolant |
---|---|
Description |
The fluid used for the coolant in the evaporator. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/evaporationMediumType |
---|---|
Description |
ColdLiquid: Evaporator is using liquid type of fluid to exchange heat with refrigerant. ColdAir: Evaporator is using air to exchange heat with refrigerant. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/failPosition |
---|---|
Description |
Specifies the required fail-safe position of the actuator. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/finishColor |
---|---|
Description |
Finish color for cooled beam. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/fireExit |
---|---|
Description |
Indication whether this object is designed to serve as an exit in the case of fire (TRUE) or not (FALSE). Here whether the transport element (in case of e.g., a lift) is designed to serve as a fire exit, e.g., for fire escape purposes. |
Range(s) | xsd:booleanc |
URI | https://saref.etsi.org/saref4bldg/flowArrangement |
---|---|
Description |
CounterFlow: Air and water flow enter in different directions. CrossFlow: Air and water flow are perpendicular. ParallelFlow: air and water flow enter in same directions. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/frameSize |
---|---|
Description |
Designation of the frame size according to the named range of frame sizes designated at the place of use or according to a given standard. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/frameType |
---|---|
Description |
The type of frame used by the damper (e.g., Standard, Single Flange, Single Reversed Flange, Double Flange, etc.). |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/hasDefrost |
---|---|
Description |
Whether the heat exchanger has defrost function or not. |
Range(s) | xsd:booleanc |
URI | https://saref.etsi.org/saref4bldg/hasExteriorInsulation |
---|---|
Description |
TRUE if the silencer has exterior insulation. FALSE if it does not. |
Range(s) | xsd:booleanc |
URI | https://saref.etsi.org/saref4bldg/hasHotGasBypass |
---|---|
Description |
Whether or not hot gas bypass is provided for the compressor. TRUE = Yes, FALSE = No. |
Range(s) | xsd:booleanc |
URI | https://saref.etsi.org/saref4bldg/hasLock |
---|---|
Description |
Indication of whether a switching device has a key operated lock (=TRUE) or not (= FALSE). |
Range(s) | xsd:booleanc |
URI | https://saref.etsi.org/saref4bldg/hasPartWinding |
---|---|
Description |
Indication of whether the motor is single speed, i.e. has a single winding (= FALSE) or multi-speed i.e.has part winding (= TRUE) . |
Range(s) | xsd:booleanc |
URI | https://saref.etsi.org/saref4bldg/hasTurbulator |
---|---|
Description |
TRUE if the tube has a turbulator, FALSE if it does not. |
Range(s) | xsd:booleanc |
URI | https://saref.etsi.org/saref4bldg/heatTransferDimension |
---|---|
Description |
Indicates how heat is transmitted according to the shape of the space heater. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/heatTransferMedium |
---|---|
Description |
Enumeration defining the heat transfer medium if applicable. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/heatTransferTypeEnum |
---|---|
Description |
Type of heat transfer between the two air streams. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/integratedLightingType |
---|---|
Description |
Integrated lighting in cooled beam. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/internalControl |
---|---|
Description |
Internal modulation control. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/isExternal |
---|---|
Description |
Indication whether the element is designed for use in the exterior (TRUE) or not (FALSE). If (TRUE) it is an external element and faces the outside of the building. |
Range(s) | xsd:booleanc |
URI | https://saref.etsi.org/saref4bldg/isFreeHanging |
---|---|
Description |
Is it free hanging type (not mounted in a false ceiling)? |
Range(s) | xsd:booleanc |
URI | https://saref.etsi.org/saref4bldg/isGuarded |
---|---|
Description |
Indication of whether the motor enclosure is guarded (= TRUE) or not (= FALSE). |
Range(s) | xsd:booleanc |
URI | https://saref.etsi.org/saref4bldg/isIlluminated |
---|---|
Description |
An indication of whether there is an illuminated indicator to show that the switch is on (=TRUE) or not (= FALSE). |
Range(s) | xsd:booleanc |
URI | https://saref.etsi.org/saref4bldg/isNeutralPrimaryTerminalAvailable |
---|---|
Description |
An indication of whether the neutral point of the primary winding is available as a terminal (=TRUE) or not (= FALSE). |
Range(s) | xsd:booleanc |
URI | https://saref.etsi.org/saref4bldg/isNeutralSecondaryTerminalAvailable |
---|---|
Description |
An indication of whether the neutral point of the secondary winding is available as a terminal (=TRUE) or not (= FALSE). |
Range(s) | xsd:booleanc |
URI | https://saref.etsi.org/saref4bldg/isPluggableOutlet |
---|---|
Description |
Indication of whether the outlet accepts a loose plug connection (= TRUE) or whether it is directly connected (= FALSE) or whether the form of connection has not yet been determined (= UNKNOWN). |
Range(s) | xsd:booleanc |
URI | https://saref.etsi.org/saref4bldg/isWaterStorageHeater |
---|---|
Description |
This is used to identify if the boiler has storage capacity (TRUE). If FALSE, then there is no storage capacity built into the boiler, such as an instantaneous hot water heater. |
Range(s) | xsd:booleanc |
URI | https://saref.etsi.org/saref4bldg/lampBallastType |
---|---|
Description |
The type of ballast used to stabilise gas discharge by limiting the current during operation and to deliver the necessary striking voltage for starting. Ballasts are needed to operate Discharge Lamps such as Fluorescent, Compact Fluorescent, High-pressure Mercury, Metal Halide and High-pressure Sodium Lamps. Magnetic ballasts are chokes which limit the current passing through a lamp connected in series on the principle of self-induction. The resultant current and power are decisive for the efficient operation of the lamp. A specially designed ballast is required for every type of lamp to comply with lamp rating in terms of Luminous Flux, Color Appearance and service life. The two types of magnetic ballasts for fluorescent lamps are KVG Conventional (EC-A series) and VVG Low-loss ballasts (EC-B series). Low-loss ballasts have a higher efficiency, which means reduced ballast losses and a lower thermal load. Electronic ballasts are used to run fluorescent lamps at high frequencies (approx. 35 - 40 kHz). |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/lampCompensationType |
---|---|
Description |
Identifies the form of compensation used for power factor correction and radio suppression. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/legend |
---|---|
Description |
A text inscribed or applied to the switch as a legend to indicate purpose or function. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/manualOverride |
---|---|
Description |
Identifies whether hand-operated operation is provided as an override (= TRUE) or not (= FALSE). Note that this value should be set to FALSE by default in the case of a Hand Operated Actuator. |
Range(s) | xsd:booleanc |
URI | https://saref.etsi.org/saref4bldg/mechanicalOperated |
---|---|
Description |
Indication whether the element is operated machanically (TRUE) or not, i.e. manually (FALSE). |
Range(s) | xsd:booleanc |
URI | https://saref.etsi.org/saref4bldg/mediaSource |
---|---|
Description |
Indicates media sources and corresponding names of ports (DistributionPort with FlowDirection=SINK and PredefinedType=AUDIOVISUAL) or aggregated audio/video components (AudioVisualAppliance). |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/motorDriveType |
---|---|
Description |
Motor drive type: DIRECTDRIVE: Direct drive. BELTDRIVE: Belt drive. COUPLING: Coupling. OTHER: Other type of motor drive. UNKNOWN: Unknown motor drive type. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/motorEnclosureType |
---|---|
Description |
A list of the available types of motor enclosure from which that required may be selected. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/numberOfBlades |
---|---|
Description |
Number of blades. |
Range(s) | xsd:integerc |
URI | https://saref.etsi.org/saref4bldg/numberOfCells |
---|---|
Description |
Number of cells in one cooling tower unit. |
Range(s) | xsd:integerc |
URI | https://saref.etsi.org/saref4bldg/numberOfCircuits |
---|---|
Description |
Number of parallel fluid tube circuits. |
Range(s) | xsd:integerc |
URI | https://saref.etsi.org/saref4bldg/numberOfGangs |
---|---|
Description |
Number of gangs/buttons on this switch. |
Range(s) | xsd:integerc |
URI | https://saref.etsi.org/saref4bldg/numberOfPanels |
---|---|
Description |
Number of panels. |
Range(s) | xsd:integerc |
URI | https://saref.etsi.org/saref4bldg/numberOfRows |
---|---|
Description |
Number of tube rows in the tube bundle assembly. |
Range(s) | xsd:integerc |
URI | https://saref.etsi.org/saref4bldg/numberOfSections |
---|---|
Description |
Number of sections used. |
Range(s) | xsd:integerc |
URI | https://saref.etsi.org/saref4bldg/numberOsSockets |
---|---|
Description |
The number of sockets that may be connected. In case of inconsistency, sockets defined on ports take precedence. |
Range(s) | xsd:integerc |
URI | https://saref.etsi.org/saref4bldg/operatingMode |
---|---|
Description |
Identifies the operating mode of the boiler. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/operation |
---|---|
Description |
The operational mechanism for the damper operation. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/orientation |
---|---|
Description |
The intended orientation for the damper as specified by the manufacturer. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/patternType |
---|---|
Description |
Defines the types of pattern (or shape of a tank that may be specified. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/pipeConnectionEnum |
---|---|
Description |
The manner in which the pipe connection is made to the cooled beam. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/placementType |
---|---|
Description |
Indicates how the device is designed to be placed. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/powerSource |
---|---|
Description |
Type of power driving the compressor. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/readOutType |
---|---|
Description |
Indication of the form that readout from the meter takes. In the case of a dial read out, this may comprise multiple dials that give a cumulative reading and/or a mechanical odometer. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/refrigerantClass |
---|---|
Description |
Refrigerant class used by the compressor. CFC: Chlorofluorocarbons. HCFC: Hydrochlorofluorocarbons. HFC: Hydrofluorocarbons. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/remoteReading |
---|---|
Description |
Indicates whether the meter has a connection for remote reading through connection of a communication device (set TRUE) or not (set FALSE). |
Range(s) | xsd:booleanc |
URI | https://saref.etsi.org/saref4bldg/roughness |
---|---|
Description |
A measure of the vertical deviations of the surface. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/secondaryCurrentType |
---|---|
Description |
A list of the secondary current types that can result from transformer output. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/shadingDeviceType |
---|---|
Description |
Specifies the type of shading device. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/sprayType |
---|---|
Description |
SprayFilled: Water is sprayed into airflow. SplashTypeFill: water cascades over successive rows of splash bars. FilmTypeFill: water flows in a thin layer over closely spaced sheets. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/standard |
---|---|
Description |
The designation of the standard applicable for the definition of the characteristics of the unit. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/storageType |
---|---|
Description |
Defines the general material category intended to be stored. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/switchFunction |
---|---|
Description |
Indicates types of switches which differs in functionality. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/temperatureClassification |
---|---|
Description |
Enumeration defining the temperature classification of the space heater surface temperature. low temperature - surface temperature is relatively low, usually heated by hot water or electricity. high temperature - surface temperature is relatively high, usually heated by gas or steam. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/transformerVectorGroup |
---|---|
Description |
List of the possible vector groups for the transformer from which that required may be set. Values in the enumeration list follow a standard international code where the first letter describes how the primary windings are connected, the second letter describes how the secondary windings are connected, and the numbers describe the rotation of voltages and currents from the primary to the secondary side in multiples of 30 degrees. D: means that the windings are delta-connected. Y: means that the windings are star-connected. Z: means that the windings are zig-zag connected (a special start-connected providing low reactance of the transformer). The connectivity is only relevant for three-phase transformers. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/valveMechanism |
---|---|
Description |
The mechanism by which the valve function is achieved where: BALL: Valve that has a ported ball that can be turned relative to the body seat ports. BUTTERFLY: Valve in which a streamlined disc pivots about a diametric axis. CONFIGUREDGATE: Screwdown valve in which the closing gate is shaped in a configured manner to have a more precise control of pressure and flow change across the valve. GLAND: Valve with a tapered seating, in which a rotatable plug is retained by means of a gland and gland packing. GLOBE: Screwdown valve that has a spherical body. LUBRICATEDPLUG: Plug valve in which a lubricant is injected under pressure between the plug face and the body. NEEDLE: Valve for regulating the flow in or from a pipe, in which a slender cone moves along the axis of flow to close against a fixed conical seat. PARALLELSLIDE: Screwdown valve that has a machined plate that slides in formed grooves to form a seal. PLUG: Valve that has a ported plug that can be turned relative to the body seat ports. WEDGEGATE: Screwdown valve that has a wedge shaped plate fitting into tapered guides to form a seal. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/valveOperation |
---|---|
Description |
The method of valve operation where: DROPWEIGHT: A valve that is closed by the action of a weighted lever being released, the weight normally being prevented from dropping by being held by a wire, the closure normally being made by the action of heat on a fusible link in the wire FLOAT: A valve that is opened and closed by the action of a float that rises and falls with water level. The float may be a ball attached to a lever or other mechanism HYDRAULIC: A valve that is opened and closed by hydraulic actuation LEVER: A valve that is opened and closed by the action of a lever rotating the gate within the valve. LOCKSHIELD: A valve that requires the use of a special lockshield key for opening and closing, the operating mechanism being protected by a shroud during normal operation. MOTORIZED: A valve that is opened and closed by the action of an electric motor on an actuator PNEUMATIC: A valve that is opened and closed by pneumatic actuation SOLENOID: A valve that is normally held open by a magnetic field in a coil acting on the gate but that is closed immediately if the electrical current generating the magnetic field is removed. SPRING: A valve that is normally held in position by the pressure of a spring on a plate but that may be caused to open if the pressure of the fluid is sufficient to overcome the spring pressure. THERMOSTATIC: A valve in which the ports are opened or closed to maintain a required predetermined temperature. WHEEL: A valve that is opened and closed by the action of a wheel moving the gate within the valve. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/valvePattern |
---|---|
Description |
The configuration of the ports of a valve according to either the linear route taken by a fluid flowing through the valve or by the number of ports where: SINGLEPORT: Valve that has a single entry port from the system that it serves, the exit port being to the surrounding environment. ANGLED_2_PORT: Valve in which the direction of flow is changed through 90 degrees. STRAIGHT_2_PORT: Valve in which the flow is straight through. STRAIGHT_3_PORT: Valve with three separate ports. CROSSOVER_4_PORT: Valve with 4 separate ports. |
Range(s) | xsd:stringc |
URI | https://saref.etsi.org/saref4bldg/waterFlowControlSystemType |
---|---|
Description |
Factory fitted waterflow control system. |
Range(s) | xsd:stringc |
https://saref.etsi.org/saref4bldg/
http://purl.org/dc/terms/
http://www.w3.org/2003/01/geo/wgs84_pos#
http://www.w3.org/2002/07/owl#
http://www.w3.org/ns/prov#
http://www.w3.org/1999/02/22-rdf-syntax-ns#
http://www.w3.org/2000/01/rdf-schema#
https://saref.etsi.org/core/
https://schema.org/
http://www.w3.org/2004/02/skos/core#
http://purl.org/vocab/vann/
http://www.w3.org/2001/XMLSchema#
c | Classes |
op | Object Properties |
fp | Functional Properties |
dp | Data Properties |
dp | Annotation Properties |
p | Properties |
ni | Named Individuals |