SAREF extension for building

Metadata

URI
https://saref.etsi.org/saref4bldg/
Publisher(s)
None
Creator(s)
None
Modified
2020-06-05
Issued
2020-04-13
Version Information
v1.1.2
Version URI
https://saref.etsi.org/saref4bldg/v1.1.2/
License
https://forge.etsi.org/etsi-software-license
Source
https://saref.etsi.org/sources/saref4bldg/
Ontology RDF
RDF (turtle)

Description

Information about changes compared to version 1.1.1: - Updated namespaces for compatibility with SAREF v3.

Table of Contents

  1. Classes
  2. Object Properties
  3. Functional Properties
  4. Datatype Properties
  5. Annotation Properties
  6. Namespaces
  7. Legend

Overview

Pictures say 1,000 words
Figure 1: Ontology overview

Classes

Actuatorc # Classes

URI https://saref.etsi.org/core/Actuator
Is Defined By https://saref.etsi.org/core/
Description

A device responsible for moving or controlling a mechanism or system

Sub-classes Actuatorc

Devicec # Classes

URI https://saref.etsi.org/core/Device
Is Defined By https://saref.etsi.org/core/
Description

A tangible object designed to accomplish a particular task in households, common public buildings or offices. In order to accomplish this task, the device performs one or more functions. For example, a washing machine is designed to wash (task) and to accomplish this task it performs the start and stop function.

Super-classes Physical objectc
Sub-classes Transport elementc
Vibration isolatorc
Building devicec

Measurementc # Classes

URI https://saref.etsi.org/core/Measurement
Is Defined By https://saref.etsi.org/core/
Description

Represents the measured value made over a property. It is also linked to the unit of measure in which the value is expressed and the timestamp of the measurement.

Restrictions saref:hasTimestampfp only xsd:dateTimec
saref:relatesToPropertyop only saref:Propertyc
saref:isMeasuredInop exactly 1 saref:UnitOfMeasurec
saref:relatesToPropertyop exactly 1 saref:Propertyc
saref:isMeasuredInop only saref:UnitOfMeasurec

Propertyc # Classes

URI https://saref.etsi.org/core/Property
Is Defined By https://saref.etsi.org/core/
Description

An aspect of an entity that can be observable by a sensor.

Sensorc # Classes

URI https://saref.etsi.org/core/Sensor
Is Defined By https://saref.etsi.org/core/
Description

A device that detects and responds to events or changes in the physical environment such as light, motion, or temperature changes. A device that has category saref:Sensor and performs a saref:SensingFunction.

Sub-classes Sensorc

Unit of measurec # Classes

URI https://saref.etsi.org/core/UnitOfMeasure
Is Defined By https://saref.etsi.org/core/
Description

The unit of measure is a standard for measurement of a quantity, such as a Property. For example, Power is a property and Watt is a unit of power that represents a definite predetermined power: when we say 10 Watt, we actually mean 10 times the definite predetermined power called "watt". Our definition is based on the definition of unit of measure in the Ontology of units of Measure (OM). We propose here a list of some units of measure that are relevant for the purpose of the Smart Appliances ontology, but this list can be extended.

Actuatorc # Classes

URI https://saref.etsi.org/saref4bldg/Actuator
Description

An actuator is a mechanical device for moving or controlling a mechanism or system. An actuator takes energy, usually created by air, electricity, or liquid, and converts that into some kind of motion.

Super-classes Distribution control devicec
saref:Actuatorc
Restrictions fail positiondp only xsd:stringc
manual overridedp only xsd:booleanc

Air to air heat recoveryc # Classes

URI https://saref.etsi.org/saref4bldg/AirToAirHeatRecovery
Description

An air-to-air heat recovery device employs a counter-flow heat exchanger between inbound and outbound air flow. It is typically used to transfer heat from warmer air in one chamber to cooler air in the second chamber (i.e., typically used to recover heat from the conditioned air being exhausted and the outside air being supplied to a building), resulting in energy savings from reduced heating (or cooling) requirements.

Super-classes Energy conversion devicec
Restrictions heat transfer type enumdp only xsd:stringc
primary air flow rate rangeop only saref:Measurementc
primary air flow rate rangeop only saref:Measurementc
has defrostdp only xsd:booleanc
secondary air flow rate rangeop only saref:Measurementc
secondary air flow rate rangeop only saref:Measurementc
operation temperature rangeop only saref:Measurementc
operation temperature rangeop only saref:Measurementc

Alarmc # Classes

URI https://saref.etsi.org/saref4bldg/Alarm
Description

An alarm is a device that signals the existence of a condition or situation that is outside the boundaries of normal expectation or that activates such a device.

Alarms include the provision of break glass buttons and manual pull boxes that are used to activate alarms.

Super-classes Distribution control devicec

Audio visual appliancec # Classes

URI https://saref.etsi.org/saref4bldg/AudioVisualAppliance
Description

An audio-visual appliance is a device that displays, captures, transmits, or receives audio or video.

Audio-visual appliances may be fixed in place or may be able to be moved from one space to another. They may require an electrical supply that may be supplied either by an electrical circuit or provided from a local battery source. Audio-visual appliances may be connected to data circuits including specialist circuits for audio visual purposes only.

Super-classes Flow terminalc
Restrictions audio volumeop only saref:Measurementc
media sourcedp only xsd:stringc

Boilerc # Classes

URI https://saref.etsi.org/saref4bldg/Boiler
Description

A boiler is a closed, pressure-rated vessel in which water or other fluid is heated using an energy source such as natural gas, heating oil, or electricity. The fluid in the vessel is then circulated out of the boiler for use in various processes or heating applications.

Super-classes Energy conversion devicec
Restrictions water inlet temperature rangeop only saref:Measurementc
heat transfer surface areaop only saref:Measurementc
outlet temperature rangeop only saref:Measurementc
is water storage heaterdp only xsd:booleanc
water storage capacityop only saref:Measurementc
energy sourcedp only xsd:stringc
nominal part load ratioop only saref:Measurementc
water inlet temperature rangeop only saref:Measurementc
operating modedp only xsd:stringc
pressure ratingop only saref:Measurementc
nominal energy consumptionop only saref:Measurementc
outlet temperature rangeop only saref:Measurementc

Buildingc # Classes

URI https://saref.etsi.org/saref4bldg/Building
Description

A building represents a structure that provides shelter for its occupants or contents and stands in one place. The building is also used to provide a basic element within the spatial structure hierarchy for the components of a building project (together with site, storey, and space).

Restrictions has spaceop only Building spacec

Building devicec # Classes

URI https://saref.etsi.org/saref4bldg/BuildingDevice
Description

A tangible object designed to accomplish a particular task in a building.

Super-classes Building objectc
saref:Devicec
Sub-classes Distribution devicec
Shading devicec

Building objectc # Classes

URI https://saref.etsi.org/saref4bldg/BuildingObject
Description

An object in the building that can be controlled by devices, such as a door or a window that can be automatically opened or closed by an actuator. (Definition taken from SAREF 1.0)

Super-classes Physical objectc
Sub-classes Building devicec

Building spacec # Classes

URI https://saref.etsi.org/saref4bldg/BuildingSpace
Description

An entity used to define the physical spaces of the building. A building space contains devices or building objects.

Restrictions isSpaceOfop only (Buildingc or Building spacec)
has spaceop only Building spacec
containsop only Physical objectc

Burnerc # Classes

URI https://saref.etsi.org/saref4bldg/Burner
Description

A burner is a device that converts fuel into heat through combustion. It includes gas, oil, and wood burners.

Super-classes Energy conversion devicec
Restrictions energy sourcedp only xsd:stringc

Chillerc # Classes

URI https://saref.etsi.org/saref4bldg/Chiller
Description

A chiller is a device used to remove heat from a liquid via a vapor-compression or absorption refrigeration cycle to cool a fluid, typically water or a mixture of water and glycol. The chilled fluid is then used to cool and dehumidify air in a building.

Super-classes Energy conversion devicec
Restrictions nominal efficiencyop only saref:Measurementc
nominal evaporating temmperatureop only saref:Measurementc
nominal condensing temperatureop only saref:Measurementc
nominal capacityop only saref:Measurementc
nominal power consumptionop only saref:Measurementc
nominal heat rejection rateop only saref:Measurementc

Coilc # Classes

URI https://saref.etsi.org/saref4bldg/Coil
Description

A coil is a device used to provide heat transfer between non-mixing media. A common example is a cooling coil, which utilizes a finned coil in which circulates chilled water, antifreeze, or refrigerant that is used to remove heat from air moving across the surface of the coil. A coil may be used either for heating or cooling purposes by placing a series of tubes (the coil) carrying a heating or cooling fluid into an airstream. The coil may be constructed from tubes bundled in a serpentine form or from finned tubes that give a extended heat transfer surface.

Coils may also be used for non-airflow cases such as embedded in a floor slab.

Super-classes Energy conversion devicec
Restrictions nominal sensible capacityop only saref:Measurementc
nominal latent capacityop only saref:Measurementc
air flow rate range minop only saref:Measurementc
nominal uaop only saref:Measurementc
placement typedp only xsd:stringc
operation temperature rangeop only saref:Measurementc
air flow rate range maxop only saref:Measurementc
operation temperature rangeop only saref:Measurementc

Communication appliancec # Classes

URI https://saref.etsi.org/saref4bldg/CommunicationAppliance
Description

A communications appliance transmits and receives electronic or digital information as data or sound.

Communication appliances may be fixed in place or may be able to be moved from one space to another. Communication appliances require an electrical supply that may be supplied either by an electrical circuit or provided from a local battery source.

Super-classes Flow terminalc

Compressorc # Classes

URI https://saref.etsi.org/saref4bldg/Compressor
Description

A compressor is a device that compresses a fluid typically used in a refrigeration circuit.

Super-classes Flow moving devicec
Restrictions compressor speedop only saref:Measurementc
maximum part load ratioop only saref:Measurementc
nominal capacityop only saref:Measurementc
power sourcedp only xsd:stringc
ideal capacityop only saref:Measurementc
impeller diameterop only saref:Measurementc
ideal shaft powerop only saref:Measurementc
has hot gas bypassdp only xsd:booleanc
refrigerant classdp only xsd:stringc
minimum part load ratioop only saref:Measurementc

Condenserc # Classes

URI https://saref.etsi.org/saref4bldg/Condenser
Description

A condenser is a device that is used to dissipate heat, typically by condensing a substance such as a refrigerant from its gaseous to its liquid state.

Super-classes Energy conversion devicec
Restrictions refrigerant classdp only xsd:stringc
internal water volumeop only saref:Measurementc
internal refrigerant volumeop only saref:Measurementc
nominal heat transfer coefficientop only saref:Measurementc
nominal heat transfer areaop only saref:Measurementc
external surface areaop only saref:Measurementc
internal surface areaop only saref:Measurementc

Controllerc # Classes

URI https://saref.etsi.org/saref4bldg/Controller
Description

A controller is a device that monitors inputs and controls outputs within a building automation system.

A controller may be physical (having placement within a spatial structure) or logical (a software interface or aggregated within a programmable physical controller).

Super-classes Distribution control devicec

Cooled beamc # Classes

URI https://saref.etsi.org/saref4bldg/CooledBeam
Description

A cooled beam (or chilled beam) is a device typically used to cool air by circulating a fluid such as chilled water through exposed finned tubes above a space. Typically mounted overhead near or within a ceiling, the cooled beam uses convection to cool the space below it by acting as a heat sink for the naturally rising warm air of the space. Once cooled, the air naturally drops back to the floor where the cycle begins again.

Super-classes Energy conversion devicec
Restrictions nominal water flow heatingop only saref:Measurementc
nominal return water temperature heatingop only saref:Measurementc
nominal water flow coolingop only saref:Measurementc
coil lengthop only saref:Measurementc
nominal sorrounding humidity coolingop only saref:Measurementc
nominal cooling capacityop only saref:Measurementc
water pressure rangeop only saref:Measurementc
water pressure rangeop only saref:Measurementc
nominal sorrounding temperature heatingop only saref:Measurementc
finish colordp only xsd:stringc
coil widthop only saref:Measurementc
is free hangingdp only xsd:booleanc
nominal heating capacityop only saref:Measurementc
nominal supply water temperature heatingop only saref:Measurementc
nominal supply water temperature coolingop only saref:Measurementc
nominal sorrounding temperature coolingop only saref:Measurementc
nominal return water temperature coolingop only saref:Measurementc
integrated lighting typedp only xsd:stringc
water flow control system typedp only xsd:stringc
pipe connection enumdp only xsd:stringc

Cooling towerc # Classes

URI https://saref.etsi.org/saref4bldg/CoolingTower
Description

A cooling tower is a device which rejects heat to ambient air by circulating a fluid such as water through it to reduce its temperature by partial evaporation.

Super-classes Energy conversion devicec
Restrictions operation temperature rangeop only saref:Measurementc
basin reserve volumeop only saref:Measurementc
lift elevation differenceop only saref:Measurementc
ambient design wet bulb temperatureop only saref:Measurementc
spray typedp only xsd:stringc
circuit typedp only xsd:stringc
water requirementop only saref:Measurementc
flow arrangementdp only xsd:stringc
control strategydp only xsd:stringc
ambient design dry bulb temperatureop only saref:Measurementc
number of cellsdp only xsd:integerc
operation temperature rangeop only saref:Measurementc
capacity controldp only xsd:stringc
nominal capacityop only saref:Measurementc

Damperc # Classes

URI https://saref.etsi.org/saref4bldg/Damper
Description

A damper typically participates in an HVAC duct distribution system and is used to control or modulate the flow of air.

Super-classes Flow controllerc
Restrictions frame depthop only saref:Measurementc
blade edgedp only xsd:stringc
frame thicknessop only saref:Measurementc
leakage fully closedop only saref:Measurementc
operation temperature rangeop only saref:Measurementc
face areaop only saref:Measurementc
temperature ratingop only saref:Measurementc
frame typedp only xsd:stringc
air flow rate range maxop only saref:Measurementc
blade actiondp only xsd:stringc
operationdp only xsd:stringc
close off ratingop only saref:Measurementc
operation temperature rangeop only saref:Measurementc
blade shapedp only xsd:stringc
open pressure dropop only saref:Measurementc
nominal air flow rateop only saref:Measurementc
blade thicknessop only saref:Measurementc
number of bladesdp only xsd:integerc
maximum working pressureop only saref:Measurementc
orientationdp only xsd:stringc

Distribution control devicec # Classes

URI https://saref.etsi.org/saref4bldg/DistributionControlDevice
Description

Represents devices of a building automation control system that are used to impart control over elements of a distribution system. (Definition adapated from http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcsharedbldgserviceelements/lexical/ifcdistributioncontrolelement.htm)

Super-classes Distribution devicec
Sub-classes Protective device tripping unitc
Flow instrumentc
Alarmc
Sensorc
Actuatorc
Controllerc
Unitary control elementc

Distribution devicec # Classes

URI https://saref.etsi.org/saref4bldg/DistributionDevice
Description

Generalization of all devices that participate in a distribution system. (Definition adapated from http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcproductextension/lexical/ifcdistributionelement.htm)

Super-classes Building devicec
Sub-classes DistributionFlowDevicec
Distribution control devicec

DistributionFlowDevicec # Classes

URI https://saref.etsi.org/saref4bldg/DistributionFlowDevice
Description

Represents devices of a distribution system that facilitate the distribution of energy or matter, such as air, water or power. (Definition adapated from http://www.buildingsmart-tech.org/ifc/IFC4/Add1/html/schema/ifcsharedbldgserviceelements/lexical/ifcdistributionflowelement.htm)

Super-classes Distribution devicec
Sub-classes Flow treatment devicec
Flow terminalc
Flow storage devicec
Flow controllerc
Flow moving devicec
Energy conversion devicec

Duct silencerc # Classes

URI https://saref.etsi.org/saref4bldg/DuctSilencer
Description

A duct silencer is a device that is typically installed inside a duct distribution system for the purpose of reducing the noise levels from air movement, fan noise, etc. in the adjacent space or downstream of the duct silencer device.

Super-classes Flow treatment devicec
Restrictions weightop only saref:Measurementc
air flow rate range maxop only saref:Measurementc
has exterior insulationdp only xsd:booleanc
air flow rate range minop only saref:Measurementc
operation temperature rangeop only saref:Measurementc
lengthop only saref:Measurementc
maximum working pressureop only saref:Measurementc
hydraulic diameterop only saref:Measurementc
minimum working pressureop only saref:Measurementc
operation temperature rangeop only saref:Measurementc

Electric appliancec # Classes

URI https://saref.etsi.org/saref4bldg/ElectricAppliance
Description

An electric appliance is a device intended for consumer usage that is powered by electricity.

Electric appliances may be fixed in place or may be able to be moved from one space to another. Electric appliances require an electrical supply that may be supplied either by an electrical circuit or provided from a local battery source.

Super-classes Flow terminalc

Electric flow storage devicec # Classes

URI https://saref.etsi.org/saref4bldg/ElectricFlowStorageDevice
Description

An electric flow storage device is a device in which electrical energy is stored and from which energy may be progressively released.

Super-classes Flow storage devicec
Restrictions nominal supply voltageop only saref:Measurementc
nominal frequencyop only saref:Measurementc
nominal supply voltage offsetop only saref:Measurementc

Electric generatorc # Classes

URI https://saref.etsi.org/saref4bldg/ElectricGenerator
Description

An electric generator is an engine that is a machine for converting mechanical energy into electrical energy.

Super-classes Energy conversion devicec
Restrictions maximum power outputop only saref:Measurementc
electric generator efficiencyop only saref:Measurementc
start current factorop only saref:Measurementc

Electric motorc # Classes

URI https://saref.etsi.org/saref4bldg/ElectricMotor
Description

An electric motor is an engine that is a machine for converting electrical energy into mechanical energy.

Super-classes Energy conversion devicec
Restrictions te timeop only saref:Measurementc
starting timeop only saref:Measurementc
has part windingdp only xsd:booleanc
motor enclosure typedp only xsd:stringc
frame sizedp only xsd:stringc
start current factorop only saref:Measurementc
electric motor efficiencyop only saref:Measurementc
is guardeddp only xsd:booleanc
maximum power outputop only saref:Measurementc
locked rotor currentop only saref:Measurementc

Electric time controlc # Classes

URI https://saref.etsi.org/saref4bldg/ElectricTimeControl
Description

An electric time control is a device that applies control to the provision or flow of electrical energy over time.

Super-classes Flow controllerc

Energy conversion devicec # Classes

URI https://saref.etsi.org/saref4bldg/EnergyConversionDevice
Description

The distribution flow element EnergyConversionDevice defines the occurrence of a device used to perform energy conversion or heat transfer and typically participates in a flow distribution system.

Super-classes DistributionFlowDevicec
Sub-classes Evaporatorc
Electric generatorc
Chillerc
Heat exchangerc
Condenserc
Air to air heat recoveryc
Boilerc
Solar devicec
Humidifierc
Tube bundlec
Coilc
Evaporative coolerc
Electric motorc
Burnerc
Cooling towerc
Transformerc
Enginec
Cooled beamc

Enginec # Classes

URI https://saref.etsi.org/saref4bldg/Engine
Description

An engine is a device that converts fuel into mechanical energy through combustion.

Super-classes Energy conversion devicec
Restrictions energy sourcedp only xsd:stringc

Evaporative coolerc # Classes

URI https://saref.etsi.org/saref4bldg/EvaporativeCooler
Description

An evaporative cooler is a device that cools air by saturating it with water vapor.

Super-classes Energy conversion devicec
Restrictions operation temperature rangeop only saref:Measurementc
operation temperature rangeop only saref:Measurementc
heat exchange areaop only saref:Measurementc
flow arrangementdp only xsd:stringc
water requirementop only saref:Measurementc

Evaporatorc # Classes

URI https://saref.etsi.org/saref4bldg/Evaporator
Description

An evaporator is a device in which a liquid refrigerent is vaporized and absorbs heat from the surrounding fluid.

Super-classes Energy conversion devicec
Restrictions evaporation medium typedp only xsd:stringc
nominal heat transfer coefficientop only saref:Measurementc
nominal heat transfer areaop only saref:Measurementc
internal water volumeop only saref:Measurementc
evaporation coolantdp only xsd:stringc
external surface areaop only saref:Measurementc
internal surface areaop only saref:Measurementc
internal refrigerant volumeop only saref:Measurementc
refrigerant classdp only xsd:stringc

Fanc # Classes

URI https://saref.etsi.org/saref4bldg/Fan
Description

A fan is a device which imparts mechanical work on a gas. A typical usage of a fan is to induce airflow in a building services air distribution system.

Super-classes Flow moving devicec
Restrictions nominal air flow rateop only saref:Measurementc
capacity control typedp only xsd:stringc
operational riterialop only saref:Measurementc
nominal total pressureop only saref:Measurementc
operation temperature rangeop only saref:Measurementc
nominal static pressureop only saref:Measurementc
nominal power rateop only saref:Measurementc
motor drive typedp only xsd:stringc
operation temperature rangeop only saref:Measurementc
nominal rotation speedop only saref:Measurementc

Filterc # Classes

URI https://saref.etsi.org/saref4bldg/Filter
Description

A filter is an apparatus used to remove particulate or gaseous matter from fluids and gases.

Super-classes Flow treatment devicec
Restrictions operation temperature rangeop only saref:Measurementc
weightop only saref:Measurementc
nominal pressure dropop only saref:Measurementc
nominal media surface velocityop only saref:Measurementc
nominal particle geometric standard deviationop only saref:Measurementc
final resistanceop only saref:Measurementc
operation temperature rangeop only saref:Measurementc
initial resistanceop only saref:Measurementc
nominal particle geometric mean diameterop only saref:Measurementc
nominal flow rateop only saref:Measurementc
fluid flow rate rangeop only saref:Measurementc
nominal filter face velocityop only saref:Measurementc
fluid flow rate rangeop only saref:Measurementc

Fire suppression terminalc # Classes

URI https://saref.etsi.org/saref4bldg/FireSuppressionTerminal
Description

A fire suppression terminal has the purpose of delivering a fluid (gas or liquid) that will suppress a fire.

A fire suppression terminal provides for all forms of sprinkler, spreader and other form of terminal that is connected to a pipework system and intended to act in the role of suppressing a fire.

Super-classes Flow terminalc

Flow controllerc # Classes

URI https://saref.etsi.org/saref4bldg/FlowController
Description

The distribution flow element FlowController defines the occurrence of elements of a distribution system that are used to regulate flow through a distribution system. Examples include dampers, valves, switches, and relays.

Super-classes DistributionFlowDevicec
Sub-classes Switching devicec
Flow meterc
Damperc
Protective devicec
Valvec
Electric time controlc

Flow instrumentc # Classes

URI https://saref.etsi.org/saref4bldg/FlowInstrument
Description

A flow instrument reads and displays the value of a particular property of a system at a point, or displays the difference in the value of a property between two points.

Instrumentation is typically for the purpose of determining the value of the property at a point in time. It is not the purpose of an instrument to record or integrate the values over time (although they may be connected to recording devices that do perform such a function). This entity provides for all forms of mechanical flow instrument (thermometers, pressure gauges etc.) and electrical flow instruments (ammeters, voltmeters etc.)

Super-classes Distribution control devicec

Flow meterc # Classes

URI https://saref.etsi.org/saref4bldg/FlowMeter
Description

A flow meter is a device that is used to measure the flow rate in a system.

Super-classes Flow controllerc
Restrictions read out typedp only xsd:stringc
remote readingdp only xsd:booleanc

Flow moving devicec # Classes

URI https://saref.etsi.org/saref4bldg/FlowMovingDevice
Description

The distribution flow element FlowMovingDevice defines the occurrence of an apparatus used to distribute, circulate or perform conveyance of fluids, including liquids and gases (such as a pump or fan), and typically participates in a flow distribution system.

Super-classes DistributionFlowDevicec
Sub-classes Compressorc
Fanc
Pumpc

Flow storage devicec # Classes

URI https://saref.etsi.org/saref4bldg/FlowStorageDevice
Description

The distribution flow element FlowStorageDevice defines the occurrence of a device that participates in a distribution system and is used for temporary storage (such as a tank).

Super-classes DistributionFlowDevicec
Sub-classes Electric flow storage devicec
Tankc

Flow terminalc # Classes

URI https://saref.etsi.org/saref4bldg/FlowTerminal
Description

The distribution flow element FlowTerminal defines the occurrence of a permanently attached element that acts as a terminus or beginning of a distribution system (such as an air outlet, drain, water closet, or sink). A terminal is typically a point at which a system interfaces with an external environment.

Super-classes DistributionFlowDevicec
Sub-classes Communication appliancec
Fire suppression terminalc
Sanitary terminalc
Lampc
Audio visual appliancec
Space heaterc
Outletc
Electric appliancec
Medical devicec

Flow treatment devicec # Classes

URI https://saref.etsi.org/saref4bldg/FlowTreatmentDevice
Description

The distribution flow element FlowTreatmentDevice defines the occurrence of a device typically used to remove unwanted matter from a fluid, either liquid or gas, and typically participates in a flow distribution system.

Super-classes DistributionFlowDevicec
Sub-classes Filterc
Duct silencerc
Interceptorc

Heat exchangerc # Classes

URI https://saref.etsi.org/saref4bldg/HeatExchanger
Description

A heat exchanger is a device used to provide heat transfer between non-mixing media such as plate and shell and tube heat exchangers. HeatExchanger is commonly used on water-side distribution systems to recover energy from a liquid to another liquid (typically water-based), whereas AirToAirHeatRecovery is commonly used on air-side distribution systems to recover energy from a gas to a gas (usually air).

Super-classes Energy conversion devicec
Restrictions arrangementdp only xsd:stringc

Humidifierc # Classes

URI https://saref.etsi.org/saref4bldg/Humidifier
Description

A humidifier is a device that adds moisture into the air.

Super-classes Energy conversion devicec
Restrictions water requirementop only saref:Measurementc
nominal moisture gainop only saref:Measurementc
internal controldp only xsd:stringc
nominal air flow rateop only saref:Measurementc
weightop only saref:Measurementc
applicationdp only xsd:stringc

Interceptorc # Classes

URI https://saref.etsi.org/saref4bldg/Interceptor
Description

An interceptor is a device designed and installed in order to separate and retain deleterious, hazardous or undesirable matter while permitting normal sewage or liquids to discharge into a collection system by gravity.

Super-classes Flow treatment devicec
Restrictions nominal body lengthop only saref:Measurementc
cover widthop only saref:Measurementc
inlet connection sizeop only saref:Measurementc
nominal body depthop only saref:Measurementc
nominal body widthop only saref:Measurementc
ventilating pipe sizeop only saref:Measurementc
cover lengthop only saref:Measurementc
outlet connection sizeop only saref:Measurementc

Lampc # Classes

URI https://saref.etsi.org/saref4bldg/Lamp
Description

A lamp is an artificial light source such as a light bulb or tube.

Super-classes Flow terminalc
Restrictions lamp maintenance factorop only saref:Measurementc
contributed luminous fluxop only saref:Measurementc
light emitter nominal powerop only saref:Measurementc
color temperatureop only saref:Measurementc
maximum spectrumop only saref:Measurementc
lamp ballast typedp only xsd:stringc
minimum spectrumop only saref:Measurementc
color rendering indexdp only xsd:integerc
color appearancedp only xsd:stringc
lamp compensation typedp only xsd:stringc

Medical devicec # Classes

URI https://saref.etsi.org/saref4bldg/MedicalDevice
Description

A medical device is attached to a medical piping system and operates upon medical gases to perform a specific function. Medical gases include medical air, medical vacuum, oxygen, carbon dioxide, nitrogen, and nitrous oxide.

Super-classes Flow terminalc

Outletc # Classes

URI https://saref.etsi.org/saref4bldg/Outlet
Description

An outlet is a device installed at a point to receive one or more inserted plugs for electrical power or communications.

Power outlets are commonly connected within a junction box; data outlets may be directly connected to a wall. For power outlets sharing the same circuit within a junction box, the ports should indicate the logical wiring relationship to the enclosing junction box, even though they may be physically connected to a cable going to another outlet, switch, or fixture.

Super-classes Flow terminalc
Restrictions is pluggable outletdp only xsd:booleanc
number os socketsdp only xsd:integerc

Physical objectc # Classes

URI https://saref.etsi.org/saref4bldg/PhysicalObject
Description

Any Object that has a proper space region. (Definition extracted from DUL ontology)

Restrictions is contained inop only (Building spacec or Physical objectc)
containsop only Physical objectc
Sub-classes saref:Devicec
Building objectc

Protective devicec # Classes

URI https://saref.etsi.org/saref4bldg/ProtectiveDevice
Description

A protective device breaks an electrical circuit when a stated electric current that passes through it is exceeded.

A protective device provides protection against electrical current only (not as a general protective device). It may be used to represent the complete set of elements including both the tripping unit and the breaking unit that provide the protection. This may be particularly useful at earlier stages of design where the approach to breaking the electrical supply may be determined but the method of tripping may not. Alternatively, this entity may be used to specifically represent the breaking unit alone (in which case the tripping unit will also be specifically identified). This entity is specific to dedicated protective devices and excludes electrical outlets that may have circuit protection.

Super-classes Flow controllerc

Protective device tripping unitc # Classes

URI https://saref.etsi.org/saref4bldg/ProtectiveDeviceTrippingUnit
Description

A protective device tripping unit breaks an electrical circuit at a separate breaking unit when a stated electric current that passes through the unit is exceeded.

Super-classes Distribution control devicec
Restrictions standarddp only xsd:stringc
limiting terminal sizeop only saref:Measurementc

Pumpc # Classes

URI https://saref.etsi.org/saref4bldg/Pump
Description

A pump is a device which imparts mechanical work on fluids or slurries to move them through a channel or pipeline. A typical use of a pump is to circulate chilled water or heating hot water in a building services distribution system.

Super-classes Flow moving devicec
Restrictions operation temperature rangeop only saref:Measurementc
net positive suction headop only saref:Measurementc
pump flow rate rangeop only saref:Measurementc
pump flow rate rangeop only saref:Measurementc
nomminal rotation speedop only saref:Measurementc
flow resistance rangeop only saref:Measurementc
flow resistance rangeop only saref:Measurementc
operation temperature rangeop only saref:Measurementc
connection sizeop only saref:Measurementc

Sanitary terminalc # Classes

URI https://saref.etsi.org/saref4bldg/SanitaryTerminal
Description

A sanitary terminal is a fixed appliance or terminal usually supplied with water and used for drinking, cleaning or foul water disposal or that is an item of equipment directly used with such an appliance or terminal.

Super-classes Flow terminalc

Sensorc # Classes

URI https://saref.etsi.org/saref4bldg/Sensor
Description

A sensor is a device that measures a physical quantity and converts it into a signal which can be read by an observer or by an instrument.

Super-classes Distribution control devicec
saref:Sensorc

Shading devicec # Classes

URI https://saref.etsi.org/saref4bldg/ShadingDevice
Description

Shading devices are purpose built devices to protect from the sunlight, from natural light, or screening them from view. Shading devices can form part of the facade or can be mounted inside the building, they can be fixed or operable.

Super-classes Building devicec
Restrictions mechanical operateddp only xsd:booleanc
solar transmittanceop only saref:Measurementc
visible light reflectanceop only saref:Measurementc
roughnessdp only xsd:stringc
thermal transmittanceop only saref:Measurementc
visible light transmittanceop only saref:Measurementc
solar reflectanceop only saref:Measurementc
is externaldp only xsd:booleanc
shading device typedp only xsd:stringc

Solar devicec # Classes

URI https://saref.etsi.org/saref4bldg/SolarDevice
Description

A solar device converts solar radiation into other energy such as electric current or thermal energy.

Super-classes Energy conversion devicec

Space heaterc # Classes

URI https://saref.etsi.org/saref4bldg/SpaceHeater
Description

Space heaters utilize a combination of radiation and/or natural convection using a heating source such as electricity, steam or hot water to heat a limited space or area. Examples of space heaters include radiators, convectors, baseboard and finned-tube heaters.

UnitaryEquipment should be used for packaged units supporting a combination of heating, cooling, and/or dehumidification; Coil should be used for coil-based floor heating.

Super-classes Flow terminalc
Restrictions body massop only saref:Measurementc
number of panelsdp only xsd:integerc
number of sectionsdp only xsd:integerc
thermal efficiencyop only saref:Measurementc
output capacityop only saref:Measurementc
heat transfer dimensiondp only xsd:stringc
placement typedp only xsd:stringc
heat transfer mediumdp only xsd:stringc
thermal mass heat capacityop only saref:Measurementc
energy sourcedp only xsd:stringc
temperature classificationdp only xsd:stringc

Switching devicec # Classes

URI https://saref.etsi.org/saref4bldg/SwitchingDevice
Description

A switch is used in a cable distribution system (electrical circuit) to control or modulate the flow of electricity.

Switches include those used for electrical power, communications, audio-visual, or other distribution system types as determined by the available ports.

Super-classes Flow controllerc
Restrictions has lockdp only xsd:booleanc
legenddp only xsd:stringc
switch functiondp only xsd:stringc
number of gangsdp only xsd:integerc
is illuminateddp only xsd:booleanc

Tankc # Classes

URI https://saref.etsi.org/saref4bldg/Tank
Description

A tank is a vessel or container in which a fluid or gas is stored for later use.

Super-classes Flow storage devicec
Restrictions first curvature radiusop only saref:Measurementc
number of sectionsdp only xsd:integerc
access typedp only xsd:stringc
storage typedp only xsd:stringc
end shape typedp only xsd:stringc
nominal length or diameterop only saref:Measurementc
pattern typedp only xsd:stringc
second curvature radiusop only saref:Measurementc
operating weightop only saref:Measurementc
nominal depthop only saref:Measurementc
effective capacityop only saref:Measurementc
nominal volumetric capacityop only saref:Measurementc
nominal width or diameterop only saref:Measurementc

Transformerc # Classes

URI https://saref.etsi.org/saref4bldg/Transformer
Description

A transformer is an inductive stationary device that transfers electrical energy from one circuit to another.

Transformer is used to transform electric power; conversion of electric signals for other purposes is handled at other entities: Controller converts arbitrary signals, AudioVisualAppliance converts signals for audio or video streams, and CommunicationsAppliance converts signals for data or other communications usage.

Super-classes Energy conversion devicec
Restrictions transformer vector groupdp only xsd:stringc
secondary voltageop only saref:Measurementc
is neutral secondary terminal availabledp only xsd:booleanc
primary voltageop only saref:Measurementc
primary frequencyop only saref:Measurementc
real impedance ratioop only saref:Measurementc
secondary apparent powerop only saref:Measurementc
maximum apparent powerop only saref:Measurementc
secondary frequencyop only saref:Measurementc
imaginary impedance ratioop only saref:Measurementc
secondary currentop only saref:Measurementc
secondary current typedp only xsd:stringc
primary currentop only saref:Measurementc
primary apparent powerop only saref:Measurementc
is neutral primary terminal availabledp only xsd:booleanc

Transport elementc # Classes

URI https://saref.etsi.org/saref4bldg/TransportElement
Description

A transport element is a generalization of all transport related objects that move people, animals or goods within a building or building complex. The TransportElement defines the occurrence of a transport element.

Super-classes saref:Devicec
Restrictions capacity peopledp only xsd:positiveIntegerc
fire exitdp only xsd:booleanc
capacity weightop only saref:Measurementc

Tube bundlec # Classes

URI https://saref.etsi.org/saref4bldg/TubeBundle
Description

A tube bundle is a device consisting of tubes and bundles of tubes used for heat transfer and contained typically within other energy conversion devices, such as a chiller or coil.

Super-classes Energy conversion devicec
Restrictions fouling factorop only saref:Measurementc
number of rowsdp only xsd:integerc
volumenop only saref:Measurementc
outside diameterop only saref:Measurementc
staggered row spacingop only saref:Measurementc
in line row spacingop only saref:Measurementc
nominal diameterop only saref:Measurementc
horizontal spacingop only saref:Measurementc
inside diameterop only saref:Measurementc
vertical spacingop only saref:Measurementc
thermal conductivityop only saref:Measurementc
number of circuitsdp only xsd:integerc
lengthop only saref:Measurementc
has turbulatordp only xsd:booleanc

Unitary control elementc # Classes

URI https://saref.etsi.org/saref4bldg/UnitaryControlElement
Description

A unitary control element combines a number of control components into a single product, such as a thermostat or humidistat.

A unitary control element provides a housing for an aggregation of control or electrical distribution elements that, in combination, perform a singular (unitary) purpose. Each item in the aggregation may have its own geometric representation and location.

Super-classes Distribution control devicec

Valvec # Classes

URI https://saref.etsi.org/saref4bldg/Valve
Description

A valve is used in a building services piping distribution system to control or modulate the flow of the fluid.

Super-classes Flow controllerc
Restrictions valve mechanismdp only xsd:stringc
sizeop only saref:Measurementc
test pressureop only saref:Measurementc
working pressureop only saref:Measurementc
close off ratingop only saref:Measurementc
flow coefficientop only saref:Measurementc
valve operationdp only xsd:stringc
valve patterndp only xsd:stringc

Vibration isolatorc # Classes

URI https://saref.etsi.org/saref4bldg/VibrationIsolator
Description

A vibration isolator is a device used to minimize the effects of vibration transmissibility in a building.

Super-classes saref:Devicec
Restrictions vibration transmissibilityop only saref:Measurementc
maximum supported weightop only saref:Measurementc
isolator compressibilityop only saref:Measurementc
isolator static deflectionop only saref:Measurementc
heightop only saref:Measurementc

Object Properties

locationop # OPs

URI http://www.w3.org/2003/01/geo/wgs84_pos#location
Is Defined By http://www.w3.org/2003/01/geo/wgs84_pos#
Description

The relation between something and the point, or other geometrical thing in space, where it is. For example, the realtionship between a radio tower and a Point with a given lat and long. Or a relationship between a park and its outline as a closed arc of points, or a road and its location as a arc (a sequence of points). Clearly in practice there will be limit to the accuracy of any such statement, but one would expect an accuracy appropriate for the size of the object and uses such as mapping .

is measured inop # OPs

URI https://saref.etsi.org/core/isMeasuredIn
Is Defined By https://saref.etsi.org/core/
Description

A relation between a measurement and the unit of measure in which the measurement value is expressed.

relates to propertyop # OPs

URI https://saref.etsi.org/core/relatesToProperty
Is Defined By https://saref.etsi.org/core/
Description

A relation between a measurement and the property such measurement is about.

air flow rate range maxop # OPs

URI https://saref.etsi.org/saref4bldg/airFlowRateMax
Description

Maximum allowable air flow rate. Usually measured in m3/s.

air flow rate range minop # OPs

URI https://saref.etsi.org/saref4bldg/airFlowRateMin
Description

Minimum allowable air flow rate. Usually measured in m3/s.

ambient design dry bulb temperatureop # OPs

URI https://saref.etsi.org/saref4bldg/ambientDesignDryBulbTemperature
Description

Ambient design dry bulb temperature used for selecting the cooling tower. Usually measured in degrees Kelvin (K).

ambient design wet bulb temperatureop # OPs

URI https://saref.etsi.org/saref4bldg/ambientDesignWetBulbTemperature
Description

Ambient design wet bulb temperature used for selecting the cooling tower. Usually measured in degrees Kelvin (K).

maximum apparent powerop # OPs

URI https://saref.etsi.org/saref4bldg/apparentPowerMax
Description

Maximum apparent power/capacity in VA (volt ampere). Usually measured in Watts (W, J/s).

audio volumeop # OPs

URI https://saref.etsi.org/saref4bldg/audioVolume
Description

Indicates discrete audio volume levels and corresponding sound power offsets, if applicable. Missing values may be interpolated. Measured in watts.

basin reserve volumeop # OPs

URI https://saref.etsi.org/saref4bldg/basinReserveVolume
Description

Volume between operating and overflow levels in cooling tower basin. Usually measured in cubic metre (m3).

blade thicknessop # OPs

URI https://saref.etsi.org/saref4bldg/bladeThickness
Description

The thickness of the damper blade. Usually measured in millimeters (mm).

body massop # OPs

URI https://saref.etsi.org/saref4bldg/bodyMass
Description

Overall body mass of the heater. Usually measured in kilograms (kg) or grams (g).

capacity weightop # OPs

URI https://saref.etsi.org/saref4bldg/capacityWeight
Description

Capacity of the transport element measured by weight. Usually measured in kilograms (kg) or grams (g).

close off ratingop # OPs

URI https://saref.etsi.org/saref4bldg/closeOffRating
Description

Close off rating. Usually measured in Pascals (Pa, N/m2).

coil lengthop # OPs

URI https://saref.etsi.org/saref4bldg/coilLength
Description

Length of coil. Usually measured in millimeters (mm).

coil widthop # OPs

URI https://saref.etsi.org/saref4bldg/coilWidth
Description

Width of coil. Usually measured in millimeters (mm

color temperatureop # OPs

URI https://saref.etsi.org/saref4bldg/colorTemperature
Description

The color temperature of any source of radiation is defined as the temperature (in Kelvin) of a black-body or Planckian radiator whose radiation has the same chromaticity as the source of radiation. Often the values are only approximate color temperatures as the black-body radiator cannot emit radiation of every chromaticity value. The color temperatures of the commonest artificial light sources range from less than 3000K (warm white) to 4000K (intermediate) and over 5000K (daylight). Usually measured in degrees Kelvin (K).

compressor speedop # OPs

URI https://saref.etsi.org/saref4bldg/compressorSpeed
Description

Compressor speed. Usually measured in cycles/s.

connection sizeop # OPs

URI https://saref.etsi.org/saref4bldg/connectionSize
Description

The connection size of the to and from the pump. Usually measured in millimeters (mm).

containsop # OPs

URI https://saref.etsi.org/saref4bldg/contains
Description

A relation between a physical space and the objects located in such space.

Inverse properties is contained inop

contributed luminous fluxop # OPs

URI https://saref.etsi.org/saref4bldg/contributedLuminousFlux
Description

Luminous flux is a photometric measure of radiant flux, i.e. the volume of light emitted from a light source. Luminous flux is measured either for the interior as a whole or for a part of the interior (partial luminous flux for a solid angle). All other photometric parameters are derivatives of luminous flux. Luminous flux is measured in lumens (lm). The luminous flux is given as a nominal value for each lamp. Usually measured in Lumen (lm, Candela Steradian).

cover lengthop # OPs

URI https://saref.etsi.org/saref4bldg/coverLength
Description

The length measured along the x-axis in the local coordinate system or the radius (in the case of a circular shape in plan) of the cover of the oil interceptor. Usually measured in millimeters (mm).

cover widthop # OPs

URI https://saref.etsi.org/saref4bldg/coverWidth
Description

The length measured along the x-axis in the local coordinate system of the cover of the oil interceptor. Usually measured in millimeters (mm).

effective capacityop # OPs

URI https://saref.etsi.org/saref4bldg/effectiveCapacity
Description

The total effective or actual volumetric capacity of the tank. Usually measured in cubic metre (m3).B3

electric generator efficiencyop # OPs

URI https://saref.etsi.org/saref4bldg/electricGeneratorEfficiency
Description

The ratio of output capacity to intake capacity.

electric motor efficiencyop # OPs

URI https://saref.etsi.org/saref4bldg/electricMotorEfficiency
Description

The ratio of output capacity to intake capacity.

external surface areaop # OPs

URI https://saref.etsi.org/saref4bldg/externalSurfaceArea
Description

External surface area (both primary and secondary area). Usually measured in square metre (m2).

face areaop # OPs

URI https://saref.etsi.org/saref4bldg/faceArea
Description

Face area open to the airstream. Usually measured in square metre (m2).

final resistanceop # OPs

URI https://saref.etsi.org/saref4bldg/finalResistance
Description

Filter fluid resistance when replacement is required (i.e., Pressure drop at the maximum air flowrate across the filter when the filter needs replacement per ASHRAE Standard 52.1). Usually measured in Pascals (Pa, N/m2).

first curvature radiusop # OPs

URI https://saref.etsi.org/saref4bldg/firstCurvatureRadius
Description

FirstCurvatureRadius should be defined as the base or left side radius of curvature value. Usually measured in millimeters (mm).

flow coefficientop # OPs

URI https://saref.etsi.org/saref4bldg/flowCoefficient
Description

Flow coefficient (the quantity of fluid that passes through a fully open valve at unit pressure drop), typically expressed as the Kv or Cv value for the valve.

flow resistance rangeop # OPs

URI https://saref.etsi.org/saref4bldg/flowResistanceMax
Description

Allowable range of frictional resistance against which the fluid is being pumped. Usually measured in Pascals (Pa, N/m2).

flow resistance rangeop # OPs

URI https://saref.etsi.org/saref4bldg/flowResistanceMin
Description

Allowable range of frictional resistance against which the fluid is being pumped. Usually measured in Pascals (Pa, N/m2).

fluid flow rate rangeop # OPs

URI https://saref.etsi.org/saref4bldg/fluidFlowRateMax
Description

Possible range of fluid flowrate that can be delivered. Usually measured in m3/s.

fluid flow rate rangeop # OPs

URI https://saref.etsi.org/saref4bldg/fluidFlowRateMin
Description

Possible range of fluid flowrate that can be delivered. Usually measured in m3/s.

fouling factorop # OPs

URI https://saref.etsi.org/saref4bldg/foulingFactor
Description

Fouling factor of the tubes in the tube bundle. Usually measured in m2 Kelvin/Watt.

frame depthop # OPs

URI https://saref.etsi.org/saref4bldg/frameDepth
Description

The length (or depth) of the damper frame. Usually measured in millimeters (mm).

frame thicknessop # OPs

URI https://saref.etsi.org/saref4bldg/frameThickness
Description

The thickness of the damper frame material. Usually measured in millimeters (mm).

has spaceop # OPs

URI https://saref.etsi.org/saref4bldg/hasSpace
Description

Relation between a building or a building space and the spaces it can be divided into.

Inverse properties isSpaceOfop

heat exchange areaop # OPs

URI https://saref.etsi.org/saref4bldg/heatExchangeArea
Description

Heat exchange area. Usually measured in square metre (m2).

heat transfer surface areaop # OPs

URI https://saref.etsi.org/saref4bldg/heatTransferSurfaceArea
Description

Total heat transfer area of the vessel. Usually measured in square metre (m2).

heightop # OPs

URI https://saref.etsi.org/saref4bldg/height
Description

Height of the vibration isolator before tha application of load. Usually measured in millimeters (mm).

horizontal spacingop # OPs

URI https://saref.etsi.org/saref4bldg/horizontalSpacing
Description

Horizontal spacing between tubes in the tube bundle. Usually measured in millimeters (mm).

hydraulic diameterop # OPs

URI https://saref.etsi.org/saref4bldg/hydraulicDiameter
Description

Hydraulic diameter. Usually measured in millimeters (mm).

ideal capacityop # OPs

URI https://saref.etsi.org/saref4bldg/idealCapacity
Description

Compressor capacity under ideal conditions. Usually measured in Watts (W, J/s).

ideal shaft powerop # OPs

URI https://saref.etsi.org/saref4bldg/idealShaftPower
Description

Compressor shaft power under ideal conditions. Usually measured in Watts (W, J/s).

imaginary impedance ratioop # OPs

URI https://saref.etsi.org/saref4bldg/imaginaryImpedanceRatio
Description

The ratio between the imaginary part of the zero sequence impedance and the imaginary part of the positive impedance (i.e. imaginary part of the short-circuit voltage) of the transformer. Used for three-phase transformer which includes a N-conductor.

impeller diameterop # OPs

URI https://saref.etsi.org/saref4bldg/impellerDiameter
Description

Diameter of compressor impeller - used to scale performance of geometrically similar compressors. Usually measured in millimeters (mm).

in line row spacingop # OPs

URI https://saref.etsi.org/saref4bldg/inLineRowSpacing
Description

In-line tube row spacing. Usually measured in millimeters (mm).

initial resistanceop # OPs

URI https://saref.etsi.org/saref4bldg/initialResistance
Description

Initial new filter fluid resistance (i.e., pressure drop at the maximum air flowrate across the filter when the filter is new per ASHRAE Standard 52.1). Usually measured in Pascals (Pa, N/m2).

inlet connection sizeop # OPs

URI https://saref.etsi.org/saref4bldg/inletConnectionSize
Description

Size of the inlet connection. Usually measured in millimeters (mm).

inside diameterop # OPs

URI https://saref.etsi.org/saref4bldg/insideDiameter
Description

Actual inner diameter of the tube in the tube bundle. Usually measured in millimeters (mm).

internal refrigerant volumeop # OPs

URI https://saref.etsi.org/saref4bldg/internalRefrigerantVolume
Description

Internal volume of evaporator (refrigerant side). Usually measured in cubic metre (m3).

internal surface areaop # OPs

URI https://saref.etsi.org/saref4bldg/internalSurfaceArea
Description

Internal surface area. Usually measured in square metre (m2).

internal water volumeop # OPs

URI https://saref.etsi.org/saref4bldg/internalWaterVolume
Description

Internal volume of evaporator (water side). Usually measured in cubic metre (m3).

is contained inop # OPs

URI https://saref.etsi.org/saref4bldg/isContainedIn
Description

A relation between an object and the physical space in which it is located.

isSpaceOfop # OPs

URI https://saref.etsi.org/saref4bldg/isSpaceOf
Description

Relation between a building space and the building or building space it belongs to.

isolator compressibilityop # OPs

URI https://saref.etsi.org/saref4bldg/isolatorCompressibility
Description

The compressibility of the vibration isolator.

isolator static deflectionop # OPs

URI https://saref.etsi.org/saref4bldg/isolatorStaticDeflection
Description

Static deflection of the vibration isolator. Usually measured in millimeters (mm).

lamp maintenance factorop # OPs

URI https://saref.etsi.org/saref4bldg/lampMaintenanceFactor
Description

Non recoverable losses of luminous flux of a lamp due to lamp depreciation i.e. the decreasing of light output of a luminaire due to aging and dirt.

leakage fully closedop # OPs

URI https://saref.etsi.org/saref4bldg/leakageFullyClosed
Description

Leakage when fully closed. Usually measured in m3/s.

lengthop # OPs

URI https://saref.etsi.org/saref4bldg/length
Description

The finished length of the device. Usually measured in millimeters (mm).

lift elevation differenceop # OPs

URI https://saref.etsi.org/saref4bldg/liftElevationDifference
Description

Elevation difference between cooling tower sump and the top of the tower. Usually measured in millimeters (mm).

light emitter nominal powerop # OPs

URI https://saref.etsi.org/saref4bldg/lightEmitterNominalPower
Description

Light emitter nominal power. Usually measured in Watts (W, J/s).

limiting terminal sizeop # OPs

URI https://saref.etsi.org/saref4bldg/limitingTerminalSize
Description

The maximum terminal size capacity of the device. Usually measured in square metre (m2).

locked rotor currentop # OPs

URI https://saref.etsi.org/saref4bldg/lockedRotorCurrent
Description

Input current when a motor armature is energized but not rotating. Usually measured in Ampere (A).

net positive suction headop # OPs

URI https://saref.etsi.org/saref4bldg/netPositiveSuctionHead
Description

Minimum liquid pressure at the pump inlet to prevent cavitation. Usually measured in Pascals (Pa, N/m2).

nominal air flow rateop # OPs

URI https://saref.etsi.org/saref4bldg/nominalAirFlowRate
Description

Nominal rate of air flow. Usually measured in m3/s.

nominal body depthop # OPs

URI https://saref.etsi.org/saref4bldg/nominalBodyDepth
Description

Nominal or quoted =length, measured along the z-axis of the local coordinate system of the object, of the body of the object. Usually measured in millimeters (mm).

nominal body lengthop # OPs

URI https://saref.etsi.org/saref4bldg/nominalBodyLength
Description

Nominal or quoted length, measured along the x-axis of the local coordinate system of the object, of the body of the object. Usually measured in millimeters (mm).

nominal body widthop # OPs

URI https://saref.etsi.org/saref4bldg/nominalBodyWidth
Description

Nominal or quoted length, measured along the y-axis of the local coordinate system of the object, of the body of the object. Usually measured in millimeters (mm).

nominal capacityop # OPs

URI https://saref.etsi.org/saref4bldg/nominalCapacity
Description

Nominal capacity. Usually measured in Watts (W, J/s).

nominal condensing temperatureop # OPs

URI https://saref.etsi.org/saref4bldg/nominalCondensingTemperature
Description

Chiller condensing temperature. Usually measured in degrees Kelvin (K).

nominal cooling capacityop # OPs

URI https://saref.etsi.org/saref4bldg/nominalCoolingCapacity
Description

Nominal cooling capacity. Usually measured in Watts (W, J/s).

nominal depthop # OPs

URI https://saref.etsi.org/saref4bldg/nominalDepth
Description

The nominal depth of the tank. Note: Not required for a horizontal cylindrical tank. Usually measured in millimeters (mm).

nominal diameterop # OPs

URI https://saref.etsi.org/saref4bldg/nominalDiameter
Description

Nominal diameter or width of the tubes in the tube bundle. Usually measured in millimeters (mm).

nominal efficiencyop # OPs

URI https://saref.etsi.org/saref4bldg/nominalEfficiency
Description

Nominal chiller efficiency under nominal conditions.

nominal energy consumptionop # OPs

URI https://saref.etsi.org/saref4bldg/nominalEnergyConsumption
Description

Nominal fuel consumption rate required to produce the total boiler heat output. Usually measured in Watts (W, J/s).

nominal evaporating temmperatureop # OPs

URI https://saref.etsi.org/saref4bldg/nominalEvaporatingTemmperature
Description

Chiller evaporating temperature.Usually measured in degrees Kelvin (K).

nominal filter face velocityop # OPs

URI https://saref.etsi.org/saref4bldg/nominalFilterFaceVelocity
Description

Filter face velocity. Usually measured in m/s.

nominal flow rateop # OPs

URI https://saref.etsi.org/saref4bldg/nominalFlowRate
Description

Nominal fluid flow rate through the filter. Usually measured in m3/s.

nominal frequencyop # OPs

URI https://saref.etsi.org/saref4bldg/nominalFrequency
Description

The nominal frequency of the supply. Usually measured in cycles/s or Hertz (Hz).

nominal heat rejection rateop # OPs

URI https://saref.etsi.org/saref4bldg/nominalHeatRejectionRate
Description

Sum of the refrigeration effect and the heat equivalent of the power input to the compressor. Usually measured in Watts (W, J/s).

nominal heat transfer areaop # OPs

URI https://saref.etsi.org/saref4bldg/nominalHeatTransferArea
Description

Nominal heat transfer surface area associated with nominal overall heat transfer coefficient. Usually measured in square metre (m2).

nominal heat transfer coefficientop # OPs

URI https://saref.etsi.org/saref4bldg/nominalHeatTransferCoefficient
Description

Nominal overall heat transfer coefficient associated with nominal heat transfer area. Usually measured in Watts/m2 Kelvin.

nominal heating capacityop # OPs

URI https://saref.etsi.org/saref4bldg/nominalHeatingCapacity
Description

Nominal heating capacity. Usually measured in Watts (W, J/s).

nominal latent capacityop # OPs

URI https://saref.etsi.org/saref4bldg/nominalLatentCapacity
Description

Nominal latent capacity. Usually measured in Watts (W, J/s).

nominal length or diameterop # OPs

URI https://saref.etsi.org/saref4bldg/nominalLengthOrDiameter
Description

The nominal length or, in the case of a vertical cylindrical tank, the nominal diameter of the tank. Usually measured in millimeters (mm).

nominal media surface velocityop # OPs

URI https://saref.etsi.org/saref4bldg/nominalMediaSurfaceVelocity
Description

Average fluid velocity at the media surface. Usually measured in m/s.

nominal moisture gainop # OPs

URI https://saref.etsi.org/saref4bldg/nominalMoistureGain
Description

Nominal rate of water vapor added into the airstream. Usually measured in kg/s.

nominal part load ratioop # OPs

URI https://saref.etsi.org/saref4bldg/nominalPartLoadRatio
Description

Allowable part load ratio range.

nominal particle geometric mean diameterop # OPs

URI https://saref.etsi.org/saref4bldg/nominalParticleGeometricMeanDiameter
Description

Particle geometric mean diameter associated with nominal efficiency. Usually measured in millimeters (mm).

nominal particle geometric standard deviationop # OPs

URI https://saref.etsi.org/saref4bldg/nominalParticleGeometricStandardDeviation
Description

Particle geometric standard deviation associated with nominal efficiency.

nominal power consumptionop # OPs

URI https://saref.etsi.org/saref4bldg/nominalPowerConsumption
Description

Nominal total power consumption. Usually measured in Watts (W, J/s).

nominal power rateop # OPs

URI https://saref.etsi.org/saref4bldg/nominalPowerRate
Description

Nominal fan power rate.Usually measured in Watts (W, J/s).

nominal pressure dropop # OPs

URI https://saref.etsi.org/saref4bldg/nominalPressureDrop
Description

Total pressure drop across the filter. Usually measured in Pascals (Pa, N/m2).

nominal return water temperature coolingop # OPs

URI https://saref.etsi.org/saref4bldg/nominalReturnWaterTemperatureCooling
Description

Nominal return water temperature (refers to nominal cooling capacity). Usually measured in degrees Kelvin (K).

nominal return water temperature heatingop # OPs

URI https://saref.etsi.org/saref4bldg/nominalReturnWaterTemperatureHeating
Description

Nominal return water temperature (refers to nominal heating capacity). Usually measured in degrees Kelvin (K).

nominal rotation speedop # OPs

URI https://saref.etsi.org/saref4bldg/nominalRotationSpeed
Description

Nominal fan wheel speed. Usually measured in cycles/s.

nominal sensible capacityop # OPs

URI https://saref.etsi.org/saref4bldg/nominalSensibleCapacity
Description

Nominal sensible capacity. Usually measured in Watts (W, J/s).

nominal sorrounding humidity coolingop # OPs

URI https://saref.etsi.org/saref4bldg/nominalSorroundingHumidityCooling
Description

Nominal surrounding humidity (refers to nominal cooling capacity). Usually measured in degrees Kelvin (K).

nominal sorrounding temperature coolingop # OPs

URI https://saref.etsi.org/saref4bldg/nominalSorroundingTemperatureCooling
Description

Nominal surrounding temperature (refers to nominal cooling capacity). Usually measured in degrees Kelvin (K).

nominal sorrounding temperature heatingop # OPs

URI https://saref.etsi.org/saref4bldg/nominalSorroundingTemperatureHeating
Description

Nominal surrounding temperature (refers to nominal heating capacity). Usually measured in degrees Kelvin (K).

nominal static pressureop # OPs

URI https://saref.etsi.org/saref4bldg/nominalStaticPressure
Description

The static pressure within the air stream that the fan must overcome to insure designed circulation of air. Usually measured in Pascals (Pa, N/m2).

nominal supply voltageop # OPs

URI https://saref.etsi.org/saref4bldg/nominalSupplyVoltage
Description

The nominal voltage of the supply. Usually measured in Volts (V, W/A).

nominal supply voltage offsetop # OPs

URI https://saref.etsi.org/saref4bldg/nominalSupplyVoltageMax
Description

The maximum and minimum allowed voltage of the supply e.g. boundaries of 380V/440V may be applied for a nominal voltage of 400V.

nominal supply voltage offsetop # OPs

URI https://saref.etsi.org/saref4bldg/nominalSupplyVoltageMin
Description

The maximum and minimum allowed voltage of the supply e.g. boundaries of 380V/440V may be applied for a nominal voltage of 400V.

nominal supply water temperature coolingop # OPs

URI https://saref.etsi.org/saref4bldg/nominalSupplyWaterTemperatureCooling
Description

Nominal supply water temperature (refers to nominal cooling capacity). Usually measured in degrees Kelvin (K).

nominal supply water temperature heatingop # OPs

URI https://saref.etsi.org/saref4bldg/nominalSupplyWaterTemperatureHeating
Description

Nominal supply water temperature (refers to nominal heating capacity). Usually measured in degrees Kelvin (K).

nominal total pressureop # OPs

URI https://saref.etsi.org/saref4bldg/nominalTotalPressure
Description

Nominal total pressure rise across the fan. Usually measured in Pascals (Pa, N/m2).

nominal uaop # OPs

URI https://saref.etsi.org/saref4bldg/nominalUa
Description

Nominal UA value.

nominal volumetric capacityop # OPs

URI https://saref.etsi.org/saref4bldg/nominalVolumetricCapacity
Description

The total nominal or design volumetric capacity of the tank. Usually measured in cubic metre (m3).

nominal water flow coolingop # OPs

URI https://saref.etsi.org/saref4bldg/nominalWaterFlowCooling
Description

Nominal water flow (refers to nominal cooling capacity). Usually measured in m3/s.

nominal water flow heatingop # OPs

URI https://saref.etsi.org/saref4bldg/nominalWaterFlowHeating
Description

Nominal water flow (refers to nominal heating capacity). Usually measured in m3/s.

nominal width or diameterop # OPs

URI https://saref.etsi.org/saref4bldg/nominalWidthOrDiameter
Description

The nominal width or, in the case of a horizontal cylindrical tank, the nominal diameter of the tank. Note: Not required for a vertical cylindrical tank. Usually measured in millimeters (mm).

nomminal rotation speedop # OPs

URI https://saref.etsi.org/saref4bldg/nomminalRotationSpeed
Description

Pump rotational speed under nominal conditions. Usually measured in cycles/s.

open pressure dropop # OPs

URI https://saref.etsi.org/saref4bldg/openPressureDrop
Description

Total pressure drop across damper. Usually measured in Pascals (Pa, N/m2).

operating weightop # OPs

URI https://saref.etsi.org/saref4bldg/operatingWeight
Description

Operating weight of the tank including all of its contents. Usually measured in kilograms (kg) or grams (g).

operation temperature rangeop # OPs

URI https://saref.etsi.org/saref4bldg/operationTemperatureMax
Description

Allowable operation ambient (air, fluid) temperature range. Usually measured in degrees Kelvin (K).

operation temperature rangeop # OPs

URI https://saref.etsi.org/saref4bldg/operationTemperatureMin
Description

Allowable operation ambient (air, fluid) temperature range. Usually measured in degrees Kelvin (K).

operational riterialop # OPs

URI https://saref.etsi.org/saref4bldg/operationalRiterial
Description

Time of operation at maximum operational ambient air temperature. Measured in seconds (s) or days (d) or other units of time.

outlet connection sizeop # OPs

URI https://saref.etsi.org/saref4bldg/outletConnectionSize
Description

Size of the outlet connection. Usually measured in millimeters (mm).

outlet temperature rangeop # OPs

URI https://saref.etsi.org/saref4bldg/outletTemperatureMax
Description

Allowable outlet temperature of either the water or the steam. Usually measured in degrees Kelvin (K).

outlet temperature rangeop # OPs

URI https://saref.etsi.org/saref4bldg/outletTemperatureMin
Description

Allowable outlet temperature of either the water or the steam. Usually measured in degrees Kelvin (K).

output capacityop # OPs

URI https://saref.etsi.org/saref4bldg/outputCapacity
Description

Total nominal heat output as listed by the manufacturer. Usually measured in Watts (W, J/s).

outside diameterop # OPs

URI https://saref.etsi.org/saref4bldg/outsideDiameter
Description

Actual outside diameter of the tube in the tube bundle. Usually measured in millimeters (mm).

maximum part load ratioop # OPs

URI https://saref.etsi.org/saref4bldg/partLoadRatioMax
Description

Maximum part load ratio as a fraction of nominal capacity.

minimum part load ratioop # OPs

URI https://saref.etsi.org/saref4bldg/partLoadRatioMin
Description

Minimum part load ratio as a fraction of nominal capacity.

maximum power outputop # OPs

URI https://saref.etsi.org/saref4bldg/powerOutputMax
Description

The maximum output power rating of the engine. Usually measured in Watts (W, J/s).

pressure ratingop # OPs

URI https://saref.etsi.org/saref4bldg/pressureRating
Description

Nominal pressure rating of the boiler as rated by the agency having jurisdiction. Usually measured in Pascals (Pa, N/m2).

primary air flow rate rangeop # OPs

URI https://saref.etsi.org/saref4bldg/primaryAirFlowRateMax
Description

Maximum primary airflow that can be delivered. Usually measured in m3/s.

primary air flow rate rangeop # OPs

URI https://saref.etsi.org/saref4bldg/primaryAirFlowRateMin
Description

Minimum primary airflow that can be delivered. Usually measured in m3/s.

primary apparent powerop # OPs

URI https://saref.etsi.org/saref4bldg/primaryApparentPower
Description

The power in VA (volt ampere) that has been transformed and that runs into the transformer on the primary side. Usually measured in Watts (W, J/s).

primary currentop # OPs

URI https://saref.etsi.org/saref4bldg/primaryCurrent
Description

The current that is going to be transformed and that runs into the transformer on the primary side. Usually measured in Ampere (A).

primary frequencyop # OPs

URI https://saref.etsi.org/saref4bldg/primaryFrequency
Description

The frequency that is going to be transformed and that runs into the transformer on the primary side. Usually measured in cycles/s or Hertz (Hz).

primary voltageop # OPs

URI https://saref.etsi.org/saref4bldg/primaryVoltage
Description

The voltage that is going to be transformed and that runs into the transformer on the primary side. Usually measured in Volts (V, W/A).

pump flow rate rangeop # OPs

URI https://saref.etsi.org/saref4bldg/pumpFlowRateMax
Description

Allowable range of volume of fluid being pumped against the resistance specified. Usually measured in kg/s.

pump flow rate rangeop # OPs

URI https://saref.etsi.org/saref4bldg/pumpFlowRateMin
Description

Allowable range of volume of fluid being pumped against the resistance specified. Usually measured in kg/s.

real impedance ratioop # OPs

URI https://saref.etsi.org/saref4bldg/realImpedanceRatio
Description

The ratio between the real part of the zero sequence impedance and the real part of the positive impedance (i.e. real part of the short-circuit voltage) of the transformer. Used for three-phase transformer which includes a N-conductor.

second curvature radiusop # OPs

URI https://saref.etsi.org/saref4bldg/secondCurvatureRadius
Description

SecondCurvatureRadius should be defined as the top or right side radius of curvature value. Usually measured in millimeters (mm).

secondary air flow rate rangeop # OPs

URI https://saref.etsi.org/saref4bldg/secondaryAirFlowRateMax
Description

Maximum secondary airflow that can be delivered. Usually measured in Pascals (Pa, N/m2).

secondary air flow rate rangeop # OPs

URI https://saref.etsi.org/saref4bldg/secondaryAirFlowRateMin
Description

Maximum secondary airflow that can be delivered. Usually measured in Pascals (Pa, N/m2).

secondary apparent powerop # OPs

URI https://saref.etsi.org/saref4bldg/secondaryApparentPower
Description

The power in VA (volt ampere) that has been transformed and is running out of the transformer on the secondary side. Usually measured in Watts (W, J/s).

secondary currentop # OPs

URI https://saref.etsi.org/saref4bldg/secondaryCurrent
Description

The current that has been transformed and is running out of the transformer on the secondary side. Usually measured in Ampere (A).

secondary frequencyop # OPs

URI https://saref.etsi.org/saref4bldg/secondaryFrequency
Description

The frequency that has been transformed and is running out of the transformer on the secondary side. Usually measured in cycles/s or Hertz (Hz).

secondary voltageop # OPs

URI https://saref.etsi.org/saref4bldg/secondaryVoltage
Description

The voltage that has been transformed and is running out of the transformer on the secondary side. Usually measured in Volts (V, W/A).

short circuit voltageop # OPs

URI https://saref.etsi.org/saref4bldg/shortCircuitVoltage
Description

A complex number that specifies the real and imaginary parts of the short-circuit voltage at rated current of a transformer given in %.

sizeop # OPs

URI https://saref.etsi.org/saref4bldg/size
Description

The size of the connection to the valve (or to each connection for faucets, mixing valves, etc.). Usually measured in millimeters (mm).

solar reflectanceop # OPs

URI https://saref.etsi.org/saref4bldg/solarReflectance
Description

(Rsol): The ratio of incident solar radiation that is reflected by a shading system (also named _e). Note the following equation Asol + Rsol + Tsol = 1

solar transmittanceop # OPs

URI https://saref.etsi.org/saref4bldg/solarTransmittance
Description

(Tsol) The ratio of incident solar radiation that directly passes through a shading system (also named _e). Note the following equation Asol + Rsol + Tsol = 1

maximum spectrumop # OPs

URI https://saref.etsi.org/saref4bldg/spectrumMax
Description

The spectrum of radiation describes its composition with regard to wavelength. Light, for example, as the portion of electromagnetic radiation that is visible to the human eye, is radiation with wavelengths in the range of approx. 380 to 780 nm (1 nm = 10 m). The corresponding range of colours varies from violet to indigo, blue, green, yellow, orange, and red. These colours form a continuous spectrum, in which the various spectral sectors merge into each other.

minimum spectrumop # OPs

URI https://saref.etsi.org/saref4bldg/spectrumMin
Description

The spectrum of radiation describes its composition with regard to wavelength. Light, for example, as the portion of electromagnetic radiation that is visible to the human eye, is radiation with wavelengths in the range of approx. 380 to 780 nm (1 nm = 10 m). The corresponding range of colours varies from violet to indigo, blue, green, yellow, orange, and red. These colours form a continuous spectrum, in which the various spectral sectors merge into each other.

staggered row spacingop # OPs

URI https://saref.etsi.org/saref4bldg/staggeredRowSpacing
Description

Staggered tube row spacing. Usually measured in millimeters (mm).

start current factorop # OPs

URI https://saref.etsi.org/saref4bldg/startCurrentFactor
Description

IEC. Start current factor defines how large the peek starting current will become on the engine. StartCurrentFactor is multiplied to NominalCurrent and we get the start current.

starting timeop # OPs

URI https://saref.etsi.org/saref4bldg/startingTime
Description

The time (in s) needed for the motor to reach its rated speed with its driven equipment attached, starting from standstill and at the nominal voltage applied at its terminals.

maximum supported weightop # OPs

URI https://saref.etsi.org/saref4bldg/supportedWeightMax
Description

The maximum weight that can be carried by the vibration isolator. Usually measured in kilograms (kg) or grams (g).

te timeop # OPs

URI https://saref.etsi.org/saref4bldg/teTime
Description

The maximum time (in s) at which the motor could run with locked rotor when the motor is used in an EX-environment. The time indicates that a protective device should trip before this time when the starting current of the motor is slowing through the device.

temperature ratingop # OPs

URI https://saref.etsi.org/saref4bldg/temperatureRating
Description

Temperature rating. Usually measured in degrees Kelvin (K).

test pressureop # OPs

URI https://saref.etsi.org/saref4bldg/testPressure
Description

The maximum pressure to which the valve has been subjected under test. Usually measured in Pascals (Pa, N/m2).

thermal conductivityop # OPs

URI https://saref.etsi.org/saref4bldg/thermalConductivity
Description

Fouling factor of the tubes in the tube bundle. Usually measured in m2 Kelvin/Watt.

thermal efficiencyop # OPs

URI https://saref.etsi.org/saref4bldg/thermalEfficiency
Description

Overall Thermal Efficiency is defined as gross energy output of the heat transfer device divided by the energy input.

thermal mass heat capacityop # OPs

URI https://saref.etsi.org/saref4bldg/thermalMassHeatCapacity
Description

Product of component mass and specific heat.

thermal transmittanceop # OPs

URI https://saref.etsi.org/saref4bldg/thermalTransmittance
Description

Rate at which energy is transmitted through a body. Usually measured in Watts/m2 Kelvin.

ventilating pipe sizeop # OPs

URI https://saref.etsi.org/saref4bldg/ventilatingPipeSize
Description

Size of the ventilating pipe(s). Usually measured in millimeters (mm).

vertical spacingop # OPs

URI https://saref.etsi.org/saref4bldg/verticalSpacing
Description

Vertical spacing between tubes in the tube bundle.Usually measured in millimeters (mm).

vibration transmissibilityop # OPs

URI https://saref.etsi.org/saref4bldg/vibrationTransmissibility
Description

The vibration transmissibility percentage.

visible light reflectanceop # OPs

URI https://saref.etsi.org/saref4bldg/visibleLightReflectance
Description

Fraction of the visible light that is reflected by the glazing at normal incidence. It is a value without unit.

visible light transmittanceop # OPs

URI https://saref.etsi.org/saref4bldg/visibleLightTransmittance
Description

Fraction of the visible light that passes the shading system at normal incidence. It is a value without unit.

volumenop # OPs

URI https://saref.etsi.org/saref4bldg/volumen
Description

Total volume of fluid in the tubes and their headers. Usually measured in cubic metre (m3).

water inlet temperature rangeop # OPs

URI https://saref.etsi.org/saref4bldg/waterInletTemperatureMax
Description

Allowable water inlet temperature range. Usually measured in degrees Kelvin (K).

water inlet temperature rangeop # OPs

URI https://saref.etsi.org/saref4bldg/waterInletTemperatureMin
Description

Allowable water inlet temperature range. Usually measured in degrees Kelvin (K).

water pressure rangeop # OPs

URI https://saref.etsi.org/saref4bldg/waterPressureMax
Description

Allowable water circuit working pressure range. Usually measured in Pascals (Pa, N/m2).

water pressure rangeop # OPs

URI https://saref.etsi.org/saref4bldg/waterPressureMin
Description

Allowable water circuit working pressure range. Usually measured in Pascals (Pa, N/m2).

water requirementop # OPs

URI https://saref.etsi.org/saref4bldg/waterRequirement
Description

Make-up water requirement. Usually measured in m3/s.

water storage capacityop # OPs

URI https://saref.etsi.org/saref4bldg/waterStorageCapacity
Description

Water storage capacity. Usually measured in cubic metre (m3).

weightop # OPs

URI https://saref.etsi.org/saref4bldg/weight
Description

The weight of the device. Usually measured in kilograms (kg) or grams (g).

working pressureop # OPs

URI https://saref.etsi.org/saref4bldg/workingPressure
Description

The normally expected maximum working pressure of the valve. Usually measured in Pascals (Pa, N/m2).

maximum working pressureop # OPs

URI https://saref.etsi.org/saref4bldg/workingPressureMax
Description

Maximum working pressure. Usually measured in Pascals (Pa, N/m2).

minimum working pressureop # OPs

URI https://saref.etsi.org/saref4bldg/workingPressureMin
Description

Allowable minimum working pressure (relative to ambient pressure). Usually measured in Pascals (Pa, N/m2).

Functional Properties

has timestampfp # FPs

URI https://saref.etsi.org/core/hasTimestamp
Is Defined By https://saref.etsi.org/core/
Description

A relationship stating the timestamp of an entity (e.g. a measurement).

Range(s) xsd:dateTimec

Datatype Properties

has valuedp # DPs

URI https://saref.etsi.org/core/hasValue
Is Defined By https://saref.etsi.org/core/
Description

A relationship defining the value of a certain property, e.g., energy or power

access typedp # DPs

URI https://saref.etsi.org/saref4bldg/accessType
Description

Defines the types of access (or cover) to a tank that may be specified. Note that covers are generally specified for rectangular tanks. For cylindrical tanks, access will normally be via a manhole.

Range(s) xsd:stringc

applicationdp # DPs

URI https://saref.etsi.org/saref4bldg/application
Description

Humidifier application. Fixed: Humidifier installed in a ducted flow distribution system. Portable: Humidifier is not installed in a ducted flow distribution system.

Range(s) xsd:stringc

arrangementdp # DPs

URI https://saref.etsi.org/saref4bldg/arrangement
Description

Defines the basic flow arrangements for the heat exchanger: COUNTERFLOW: Counterflow heat exchanger arrangement. CROSSFLOW: Crossflow heat exchanger arrangement. PARALLELFLOW: Parallel flow heat exchanger arrangement. MULTIPASS: Multipass flow heat exchanger arrangement. OTHER: Other type of heat exchanger flow arrangement not defined above.

Range(s) xsd:stringc

blade actiondp # DPs

URI https://saref.etsi.org/saref4bldg/bladeAction
Description

Blade action.

Range(s) xsd:stringc

blade edgedp # DPs

URI https://saref.etsi.org/saref4bldg/bladeEdge
Description

Blade edge.

Range(s) xsd:stringc

blade shapedp # DPs

URI https://saref.etsi.org/saref4bldg/bladeShape
Description

Blade shape. Flat means triple V-groove.

Range(s) xsd:stringc

capacity controldp # DPs

URI https://saref.etsi.org/saref4bldg/capacityControl
Description

FanCycling: Fan is cycled on and off to control duty. TwoSpeedFan: Fan is switched between low and high speed to control duty. VariableSpeedFan: Fan speed is varied to control duty. DampersControl: Dampers modulate the air flow to control duty. BypassValveControl: Bypass valve modulates the water flow to control duty. MultipleSeriesPumps: Turn on/off multiple series pump to control duty. TwoSpeedPump: Switch between high/low pump speed to control duty. VariableSpeedPump: vary pump speed to control duty.

Range(s) xsd:stringc

capacity control typedp # DPs

URI https://saref.etsi.org/saref4bldg/capacityControlType
Description

InletVane: Control by adjusting inlet vane. VariableSpeedDrive: Control by variable speed drive. BladePitchAngle: Control by adjusting blade pitch angle. TwoSpeed: Control by switch between high and low speed. DischargeDamper: Control by modulating discharge damper.

Range(s) xsd:stringc

capacity peopledp # DPs

URI https://saref.etsi.org/saref4bldg/capacityPeople
Description

Capacity of the transportation element measured in numbers of person.

Range(s) xsd:nonNegativeIntegerc

circuit typedp # DPs

URI https://saref.etsi.org/saref4bldg/circuitType
Description

OpenCircuit: Exposes water directly to the cooling atmosphere. CloseCircuit: The fluid is separated from the atmosphere by a heat exchanger. Wet: The air stream or the heat exchange surface is evaporatively cooled. Dry: No evaporation into the air stream. DryWet: A combination of a dry tower and a wet tower.

Range(s) xsd:stringc

color appearancedp # DPs

URI https://saref.etsi.org/saref4bldg/colorAppearance
Description

In both the DIN and CIE standards, artificial light sources are classified in terms of their color appearance. To the human eye they all appear to be white the difference can only be detected by direct comparison. Visual performance is not directly affected by differences in color appearance.

Range(s) xsd:stringc

color rendering indexdp # DPs

URI https://saref.etsi.org/saref4bldg/colorRenderingIndex
Description

The CRI indicates how well a light source renders eight standard colors compared to perfect reference lamp with the same color temperature. The CRI scale ranges from 1 to 100, with 100 representing perfect rendering properties.

Range(s) xsd:integerc

control strategydp # DPs

URI https://saref.etsi.org/saref4bldg/controlStrategy
Description

FixedExitingWaterTemp: The capacity is controlled to maintain a fixed exiting water temperature. WetBulbTempReset: The set-point is reset based on the wet-bulb temperature.

Range(s) xsd:stringc

end shape typedp # DPs

URI https://saref.etsi.org/saref4bldg/endShapeType
Description

Defines the types of end shapes that can be used for preformed tanks. The convention for reading these enumerated values is that for a vertical cylinder, the first value is the base and the second is the top for a horizontal cylinder, the order of reading should be left to right. For a speherical tank, the value UNSET should be used.B5

Range(s) xsd:stringc

energy sourcedp # DPs

URI https://saref.etsi.org/saref4bldg/energySource
Description

The source of energy.

Range(s) xsd:stringc

evaporation coolantdp # DPs

URI https://saref.etsi.org/saref4bldg/evaporationCoolant
Description

The fluid used for the coolant in the evaporator.

Range(s) xsd:stringc

evaporation medium typedp # DPs

URI https://saref.etsi.org/saref4bldg/evaporationMediumType
Description

ColdLiquid: Evaporator is using liquid type of fluid to exchange heat with refrigerant. ColdAir: Evaporator is using air to exchange heat with refrigerant.

Range(s) xsd:stringc

fail positiondp # DPs

URI https://saref.etsi.org/saref4bldg/failPosition
Description

Specifies the required fail-safe position of the actuator.

Range(s) xsd:stringc

finish colordp # DPs

URI https://saref.etsi.org/saref4bldg/finishColor
Description

Finish color for cooled beam.

Range(s) xsd:stringc

fire exitdp # DPs

URI https://saref.etsi.org/saref4bldg/fireExit
Description

Indication whether this object is designed to serve as an exit in the case of fire (TRUE) or not (FALSE). Here whether the transport element (in case of e.g., a lift) is designed to serve as a fire exit, e.g., for fire escape purposes.

Range(s) xsd:booleanc

flow arrangementdp # DPs

URI https://saref.etsi.org/saref4bldg/flowArrangement
Description

CounterFlow: Air and water flow enter in different directions. CrossFlow: Air and water flow are perpendicular. ParallelFlow: air and water flow enter in same directions.

Range(s) xsd:stringc

frame sizedp # DPs

URI https://saref.etsi.org/saref4bldg/frameSize
Description

Designation of the frame size according to the named range of frame sizes designated at the place of use or according to a given standard.

Range(s) xsd:stringc

frame typedp # DPs

URI https://saref.etsi.org/saref4bldg/frameType
Description

The type of frame used by the damper (e.g., Standard, Single Flange, Single Reversed Flange, Double Flange, etc.).

Range(s) xsd:stringc

has defrostdp # DPs

URI https://saref.etsi.org/saref4bldg/hasDefrost
Description

Whether the heat exchanger has defrost function or not.

Range(s) xsd:booleanc

has exterior insulationdp # DPs

URI https://saref.etsi.org/saref4bldg/hasExteriorInsulation
Description

TRUE if the silencer has exterior insulation. FALSE if it does not.

Range(s) xsd:booleanc

has hot gas bypassdp # DPs

URI https://saref.etsi.org/saref4bldg/hasHotGasBypass
Description

Whether or not hot gas bypass is provided for the compressor. TRUE = Yes, FALSE = No.

Range(s) xsd:booleanc

has lockdp # DPs

URI https://saref.etsi.org/saref4bldg/hasLock
Description

Indication of whether a switching device has a key operated lock (=TRUE) or not (= FALSE).

Range(s) xsd:booleanc

has part windingdp # DPs

URI https://saref.etsi.org/saref4bldg/hasPartWinding
Description

Indication of whether the motor is single speed, i.e. has a single winding (= FALSE) or multi-speed i.e.has part winding (= TRUE) .

Range(s) xsd:booleanc

has turbulatordp # DPs

URI https://saref.etsi.org/saref4bldg/hasTurbulator
Description

TRUE if the tube has a turbulator, FALSE if it does not.

Range(s) xsd:booleanc

heat transfer dimensiondp # DPs

URI https://saref.etsi.org/saref4bldg/heatTransferDimension
Description

Indicates how heat is transmitted according to the shape of the space heater.

Range(s) xsd:stringc

heat transfer mediumdp # DPs

URI https://saref.etsi.org/saref4bldg/heatTransferMedium
Description

Enumeration defining the heat transfer medium if applicable.

Range(s) xsd:stringc

heat transfer type enumdp # DPs

URI https://saref.etsi.org/saref4bldg/heatTransferTypeEnum
Description

Type of heat transfer between the two air streams.

Range(s) xsd:stringc

integrated lighting typedp # DPs

URI https://saref.etsi.org/saref4bldg/integratedLightingType
Description

Integrated lighting in cooled beam.

Range(s) xsd:stringc

internal controldp # DPs

URI https://saref.etsi.org/saref4bldg/internalControl
Description

Internal modulation control.

Range(s) xsd:stringc

is externaldp # DPs

URI https://saref.etsi.org/saref4bldg/isExternal
Description

Indication whether the element is designed for use in the exterior (TRUE) or not (FALSE). If (TRUE) it is an external element and faces the outside of the building.

Range(s) xsd:booleanc

is free hangingdp # DPs

URI https://saref.etsi.org/saref4bldg/isFreeHanging
Description

Is it free hanging type (not mounted in a false ceiling)?

Range(s) xsd:booleanc

is guardeddp # DPs

URI https://saref.etsi.org/saref4bldg/isGuarded
Description

Indication of whether the motor enclosure is guarded (= TRUE) or not (= FALSE).

Range(s) xsd:booleanc

is illuminateddp # DPs

URI https://saref.etsi.org/saref4bldg/isIlluminated
Description

An indication of whether there is an illuminated indicator to show that the switch is on (=TRUE) or not (= FALSE).

Range(s) xsd:booleanc

is neutral primary terminal availabledp # DPs

URI https://saref.etsi.org/saref4bldg/isNeutralPrimaryTerminalAvailable
Description

An indication of whether the neutral point of the primary winding is available as a terminal (=TRUE) or not (= FALSE).

Range(s) xsd:booleanc

is neutral secondary terminal availabledp # DPs

URI https://saref.etsi.org/saref4bldg/isNeutralSecondaryTerminalAvailable
Description

An indication of whether the neutral point of the secondary winding is available as a terminal (=TRUE) or not (= FALSE).

Range(s) xsd:booleanc

is pluggable outletdp # DPs

URI https://saref.etsi.org/saref4bldg/isPluggableOutlet
Description

Indication of whether the outlet accepts a loose plug connection (= TRUE) or whether it is directly connected (= FALSE) or whether the form of connection has not yet been determined (= UNKNOWN).

Range(s) xsd:booleanc

is water storage heaterdp # DPs

URI https://saref.etsi.org/saref4bldg/isWaterStorageHeater
Description

This is used to identify if the boiler has storage capacity (TRUE). If FALSE, then there is no storage capacity built into the boiler, such as an instantaneous hot water heater.

Range(s) xsd:booleanc

lamp ballast typedp # DPs

URI https://saref.etsi.org/saref4bldg/lampBallastType
Description

The type of ballast used to stabilise gas discharge by limiting the current during operation and to deliver the necessary striking voltage for starting. Ballasts are needed to operate Discharge Lamps such as Fluorescent, Compact Fluorescent, High-pressure Mercury, Metal Halide and High-pressure Sodium Lamps. Magnetic ballasts are chokes which limit the current passing through a lamp connected in series on the principle of self-induction. The resultant current and power are decisive for the efficient operation of the lamp. A specially designed ballast is required for every type of lamp to comply with lamp rating in terms of Luminous Flux, Color Appearance and service life. The two types of magnetic ballasts for fluorescent lamps are KVG Conventional (EC-A series) and VVG Low-loss ballasts (EC-B series). Low-loss ballasts have a higher efficiency, which means reduced ballast losses and a lower thermal load. Electronic ballasts are used to run fluorescent lamps at high frequencies (approx. 35 - 40 kHz).

Range(s) xsd:stringc

lamp compensation typedp # DPs

URI https://saref.etsi.org/saref4bldg/lampCompensationType
Description

Identifies the form of compensation used for power factor correction and radio suppression.

Range(s) xsd:stringc

legenddp # DPs

URI https://saref.etsi.org/saref4bldg/legend
Description

A text inscribed or applied to the switch as a legend to indicate purpose or function.

Range(s) xsd:stringc

manual overridedp # DPs

URI https://saref.etsi.org/saref4bldg/manualOverride
Description

Identifies whether hand-operated operation is provided as an override (= TRUE) or not (= FALSE). Note that this value should be set to FALSE by default in the case of a Hand Operated Actuator.

Range(s) xsd:booleanc

mechanical operateddp # DPs

URI https://saref.etsi.org/saref4bldg/mechanicalOperated
Description

Indication whether the element is operated machanically (TRUE) or not, i.e. manually (FALSE).

Range(s) xsd:booleanc

media sourcedp # DPs

URI https://saref.etsi.org/saref4bldg/mediaSource
Description

Indicates media sources and corresponding names of ports (DistributionPort with FlowDirection=SINK and PredefinedType=AUDIOVISUAL) or aggregated audio/video components (AudioVisualAppliance).

Range(s) xsd:stringc

motor drive typedp # DPs

URI https://saref.etsi.org/saref4bldg/motorDriveType
Description

Motor drive type: DIRECTDRIVE: Direct drive. BELTDRIVE: Belt drive. COUPLING: Coupling. OTHER: Other type of motor drive. UNKNOWN: Unknown motor drive type.

Range(s) xsd:stringc

motor enclosure typedp # DPs

URI https://saref.etsi.org/saref4bldg/motorEnclosureType
Description

A list of the available types of motor enclosure from which that required may be selected.

Range(s) xsd:stringc

number of bladesdp # DPs

URI https://saref.etsi.org/saref4bldg/numberOfBlades
Description

Number of blades.

Range(s) xsd:integerc

number of cellsdp # DPs

URI https://saref.etsi.org/saref4bldg/numberOfCells
Description

Number of cells in one cooling tower unit.

Range(s) xsd:integerc

number of circuitsdp # DPs

URI https://saref.etsi.org/saref4bldg/numberOfCircuits
Description

Number of parallel fluid tube circuits.

Range(s) xsd:integerc

number of gangsdp # DPs

URI https://saref.etsi.org/saref4bldg/numberOfGangs
Description

Number of gangs/buttons on this switch.

Range(s) xsd:integerc

number of panelsdp # DPs

URI https://saref.etsi.org/saref4bldg/numberOfPanels
Description

Number of panels.

Range(s) xsd:integerc

number of rowsdp # DPs

URI https://saref.etsi.org/saref4bldg/numberOfRows
Description

Number of tube rows in the tube bundle assembly.

Range(s) xsd:integerc

number of sectionsdp # DPs

URI https://saref.etsi.org/saref4bldg/numberOfSections
Description

Number of sections used.

Range(s) xsd:integerc

number os socketsdp # DPs

URI https://saref.etsi.org/saref4bldg/numberOsSockets
Description

The number of sockets that may be connected. In case of inconsistency, sockets defined on ports take precedence.

Range(s) xsd:integerc

operating modedp # DPs

URI https://saref.etsi.org/saref4bldg/operatingMode
Description

Identifies the operating mode of the boiler.

Range(s) xsd:stringc

operationdp # DPs

URI https://saref.etsi.org/saref4bldg/operation
Description

The operational mechanism for the damper operation.

Range(s) xsd:stringc

orientationdp # DPs

URI https://saref.etsi.org/saref4bldg/orientation
Description

The intended orientation for the damper as specified by the manufacturer.

Range(s) xsd:stringc

pattern typedp # DPs

URI https://saref.etsi.org/saref4bldg/patternType
Description

Defines the types of pattern (or shape of a tank that may be specified.

Range(s) xsd:stringc

pipe connection enumdp # DPs

URI https://saref.etsi.org/saref4bldg/pipeConnectionEnum
Description

The manner in which the pipe connection is made to the cooled beam.

Range(s) xsd:stringc

placement typedp # DPs

URI https://saref.etsi.org/saref4bldg/placementType
Description

Indicates how the device is designed to be placed.

Range(s) xsd:stringc

power sourcedp # DPs

URI https://saref.etsi.org/saref4bldg/powerSource
Description

Type of power driving the compressor.

Range(s) xsd:stringc

read out typedp # DPs

URI https://saref.etsi.org/saref4bldg/readOutType
Description

Indication of the form that readout from the meter takes. In the case of a dial read out, this may comprise multiple dials that give a cumulative reading and/or a mechanical odometer.

Range(s) xsd:stringc

refrigerant classdp # DPs

URI https://saref.etsi.org/saref4bldg/refrigerantClass
Description

Refrigerant class used by the compressor. CFC: Chlorofluorocarbons. HCFC: Hydrochlorofluorocarbons. HFC: Hydrofluorocarbons.

Range(s) xsd:stringc

remote readingdp # DPs

URI https://saref.etsi.org/saref4bldg/remoteReading
Description

Indicates whether the meter has a connection for remote reading through connection of a communication device (set TRUE) or not (set FALSE).

Range(s) xsd:booleanc

roughnessdp # DPs

URI https://saref.etsi.org/saref4bldg/roughness
Description

A measure of the vertical deviations of the surface.

Range(s) xsd:stringc

secondary current typedp # DPs

URI https://saref.etsi.org/saref4bldg/secondaryCurrentType
Description

A list of the secondary current types that can result from transformer output.

Range(s) xsd:stringc

shading device typedp # DPs

URI https://saref.etsi.org/saref4bldg/shadingDeviceType
Description

Specifies the type of shading device.

Range(s) xsd:stringc

spray typedp # DPs

URI https://saref.etsi.org/saref4bldg/sprayType
Description

SprayFilled: Water is sprayed into airflow. SplashTypeFill: water cascades over successive rows of splash bars. FilmTypeFill: water flows in a thin layer over closely spaced sheets.

Range(s) xsd:stringc

standarddp # DPs

URI https://saref.etsi.org/saref4bldg/standard
Description

The designation of the standard applicable for the definition of the characteristics of the unit.

Range(s) xsd:stringc

storage typedp # DPs

URI https://saref.etsi.org/saref4bldg/storageType
Description

Defines the general material category intended to be stored.

Range(s) xsd:stringc

switch functiondp # DPs

URI https://saref.etsi.org/saref4bldg/switchFunction
Description

Indicates types of switches which differs in functionality.

Range(s) xsd:stringc

temperature classificationdp # DPs

URI https://saref.etsi.org/saref4bldg/temperatureClassification
Description

Enumeration defining the temperature classification of the space heater surface temperature. low temperature - surface temperature is relatively low, usually heated by hot water or electricity. high temperature - surface temperature is relatively high, usually heated by gas or steam.

Range(s) xsd:stringc

transformer vector groupdp # DPs

URI https://saref.etsi.org/saref4bldg/transformerVectorGroup
Description

List of the possible vector groups for the transformer from which that required may be set. Values in the enumeration list follow a standard international code where the first letter describes how the primary windings are connected, the second letter describes how the secondary windings are connected, and the numbers describe the rotation of voltages and currents from the primary to the secondary side in multiples of 30 degrees. D: means that the windings are delta-connected. Y: means that the windings are star-connected. Z: means that the windings are zig-zag connected (a special start-connected providing low reactance of the transformer). The connectivity is only relevant for three-phase transformers.

Range(s) xsd:stringc

valve mechanismdp # DPs

URI https://saref.etsi.org/saref4bldg/valveMechanism
Description

The mechanism by which the valve function is achieved where: BALL: Valve that has a ported ball that can be turned relative to the body seat ports. BUTTERFLY: Valve in which a streamlined disc pivots about a diametric axis. CONFIGUREDGATE: Screwdown valve in which the closing gate is shaped in a configured manner to have a more precise control of pressure and flow change across the valve. GLAND: Valve with a tapered seating, in which a rotatable plug is retained by means of a gland and gland packing. GLOBE: Screwdown valve that has a spherical body. LUBRICATEDPLUG: Plug valve in which a lubricant is injected under pressure between the plug face and the body. NEEDLE: Valve for regulating the flow in or from a pipe, in which a slender cone moves along the axis of flow to close against a fixed conical seat. PARALLELSLIDE: Screwdown valve that has a machined plate that slides in formed grooves to form a seal. PLUG: Valve that has a ported plug that can be turned relative to the body seat ports. WEDGEGATE: Screwdown valve that has a wedge shaped plate fitting into tapered guides to form a seal.

Range(s) xsd:stringc

valve operationdp # DPs

URI https://saref.etsi.org/saref4bldg/valveOperation
Description

The method of valve operation where: DROPWEIGHT: A valve that is closed by the action of a weighted lever being released, the weight normally being prevented from dropping by being held by a wire, the closure normally being made by the action of heat on a fusible link in the wire FLOAT: A valve that is opened and closed by the action of a float that rises and falls with water level. The float may be a ball attached to a lever or other mechanism HYDRAULIC: A valve that is opened and closed by hydraulic actuation LEVER: A valve that is opened and closed by the action of a lever rotating the gate within the valve. LOCKSHIELD: A valve that requires the use of a special lockshield key for opening and closing, the operating mechanism being protected by a shroud during normal operation. MOTORIZED: A valve that is opened and closed by the action of an electric motor on an actuator PNEUMATIC: A valve that is opened and closed by pneumatic actuation SOLENOID: A valve that is normally held open by a magnetic field in a coil acting on the gate but that is closed immediately if the electrical current generating the magnetic field is removed. SPRING: A valve that is normally held in position by the pressure of a spring on a plate but that may be caused to open if the pressure of the fluid is sufficient to overcome the spring pressure. THERMOSTATIC: A valve in which the ports are opened or closed to maintain a required predetermined temperature. WHEEL: A valve that is opened and closed by the action of a wheel moving the gate within the valve.

Range(s) xsd:stringc

valve patterndp # DPs

URI https://saref.etsi.org/saref4bldg/valvePattern
Description

The configuration of the ports of a valve according to either the linear route taken by a fluid flowing through the valve or by the number of ports where: SINGLEPORT: Valve that has a single entry port from the system that it serves, the exit port being to the surrounding environment. ANGLED_2_PORT: Valve in which the direction of flow is changed through 90 degrees. STRAIGHT_2_PORT: Valve in which the flow is straight through. STRAIGHT_3_PORT: Valve with three separate ports. CROSSOVER_4_PORT: Valve with 4 separate ports.

Range(s) xsd:stringc

water flow control system typedp # DPs

URI https://saref.etsi.org/saref4bldg/waterFlowControlSystemType
Description

Factory fitted waterflow control system.

Range(s) xsd:stringc

Annotation Properties

creatorap # APs

URI http://purl.org/dc/terms/creator

dateCopyrightedap # APs

URI http://purl.org/dc/terms/dateCopyrighted

descriptionap # APs

URI http://purl.org/dc/terms/description

issuedap # APs

URI http://purl.org/dc/terms/issued

licenseap # APs

URI http://purl.org/dc/terms/license

modifiedap # APs

URI http://purl.org/dc/terms/modified

publisherap # APs

URI http://purl.org/dc/terms/publisher

rightsHolderap # APs

URI http://purl.org/dc/terms/rightsHolder

sourceap # APs

URI http://purl.org/dc/terms/source

titleap # APs

URI http://purl.org/dc/terms/title

preferredNamespacePrefixap # APs

URI http://purl.org/vocab/vann/preferredNamespacePrefix

preferredNamespaceUriap # APs

URI http://purl.org/vocab/vann/preferredNamespaceUri

hadPrimarySourceap # APs

URI http://www.w3.org/ns/prov#hadPrimarySource

Namespaces

default (s4bldg)
https://saref.etsi.org/saref4bldg/
dcterms
http://purl.org/dc/terms/
geo
http://www.w3.org/2003/01/geo/wgs84_pos#
owl
http://www.w3.org/2002/07/owl#
prov
http://www.w3.org/ns/prov#
rdf
http://www.w3.org/1999/02/22-rdf-syntax-ns#
rdfs
http://www.w3.org/2000/01/rdf-schema#
saref
https://saref.etsi.org/core/
sdo
https://schema.org/
skos
http://www.w3.org/2004/02/skos/core#
vann
http://purl.org/vocab/vann/
xsd
http://www.w3.org/2001/XMLSchema#

Legend

cClasses
opObject Properties
fpFunctional Properties
dpData Properties
dpAnnotation Properties
pProperties
niNamed Individuals