SAREF for Energy Flexibility

IRI:
https://saref.etsi.org/saref4ener/
Version IRI:
https://saref.etsi.org/saref4ener/v1.2.1/
Current version :
v1.2.1
Previous version :
https://saref.etsi.org/saref4ener/v1.1.2/ (visualise it with LODE )
Authors :
https://www.linkedin.com/in/bouterca/
https://www.linkedin.com/in/giulia-biagioni
https://www.linkedin.com/in/lauradaniele
Contributors :
https://www.linkedin.com/in/ana%C3%AFs-walle-050baa159/
https://www.linkedin.com/in/george-hallak-368301157/
https://www.linkedin.com/in/georgjung/
https://www.linkedin.com/in/josef-baumeister-a221422/
https://www.linkedin.com/in/mente-konsman-b0a1711/
https://www.linkedin.com/in/wilco-wijbrandi-3994ab4b/
Publisher :
https://www.etsi.org/
Imported Ontologies :
https://saref.etsi.org/core/v3.1.1/ (visualise it with LODE )
Other visualisation :
Ontology source - WebVowl

Table of Content

  1. Classes
  2. Object Properties
  3. Data Properties
  4. Named Individuals
  5. Annotation Properties
  6. Namespace Declarations

Classes

Activation delay duration descriptionc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/ActivationDelayDurationDescription

The duration description for the activation delay duration temporal entity
has super-classes
duration descriptionc

Active duration descriptionc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/ActiveDurationDescription

The duration description for the active duration (min and max, sum max and sum min) temporal entities
has super-classes
duration descriptionc

Active duration maxc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/ActiveDurationMax

The active maximum duration a power sequence can run without interruption.
has super-classes
temporal entityc

Active duration minc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/ActiveDurationMin

The active mininum duration a power sequence can run without interruption.
has super-classes
temporal entityc

Active duration sum maxc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/ActiveDurationSumMax

The active maximum duration a power sequence can run in total (summation of all active times).
has super-classes
temporal entityc

Active duration sum minc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/ActiveDurationSumMin

The active minimum duration a power sequence must run in total (summation of all active times).
has super-classes
temporal entityc

Actuator levelc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/ActuatorLevel

Independent from the ActuatorSwitch class, the ActuatorLevel class enables a user or application to model LEVEL commands (start, up, percentageAbsolute, relative, etc.). This can be used to dim a light, set the speed of an electric motor, etc.
has super-classes
actuator

Actuator switchc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/ActuatorSwitch

Basic on/off operations on a simple actuator can be modelled with the ActuatorSwitch class. Whether the function turns a device itself ON or OFF, or whether it switches a specific feature, depends on the implementation. For example, one could model the super freeze program of a freezer using ActuatorSwitch class. An ON command would then activate the super freeze program and an OFF command would deactivate it. This example shall just give an idea how ActuatorSwitch can be used for more purposes than only turning devices on and off.
has super-classes
actuator

Allowed limit rangec back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/AllowedLimitRange

The actual constraints of an Power Envelope Based Profile.
has super-classes
thingc
has sub-classes
Power Limitc
is in domain of
Limit Typeop
is in range of
allowed limit rangeop

Alternatives groupc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/AlternativesGroup

A collection of power sequences for a certain profile
has super-classes
consists of only Power sequencec
belongs toop only Power profile controlc
consists of min 1 Power sequencec
belongs toop exactly 1 Power profile controlc
alternatives group IDdp exactly 1

Anticipation duration descriptionc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/AnticipationDurationDescription

The duration description for the anticipation duration temporal entities
has super-classes
duration descriptionc

Commodity Quantityc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/CommodityQuantity

The various commodity quantities introduced by the S2 standard.
is in range of
relates to commodity quantityop
has members
Electric Power 3 Phase Symmetricni, Electric Power L1ni, Electric Power L2ni, Electric Power L3ni, Heat Flow Rateni, Heat Temperatureni, Heat Thermal Powerni, Hydrogen Flow Rateni, Natural Gas Flow Rateni, Oil Flow Rateni

Contractual Power Limitc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/ContractualPowerLimit

The contractual power limit of a device
has super-classes
Power Limitc
is in domain of
has contractual consumption Maxop, has contractual production Maxop
is in range of
is bound toop

Data pointc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/DataPoint

A data point is a quantity that is extended with various pieces of process information, namely - A creation time (instant). This is the point in time when the data point was created, which is not necessarily the time for which it is valid. In the case of soft-sensors or forecasters, a data point might have been created ahead of time, in the case of a direcet measurement a data point might created at its time of validity (or at the end of its validity time interval) and in the case of an archived value the data point might have been created after the fact. - A validity time (temporal entity) which will be named "time stamp". The validity time is the instant or interval in time in which a specific quantity is in effect. For example a room temperature might be measured at 12:00, which means it is in effect at this very instant. A specific amount of energy might me expended within the time-slot between 12:30 and 12:45, which means that the energy measurement is in effect during this time interval. - A location or topological association. For example, a measurement might be taken in a specific room, a power avarage might have been measured by a specific meter, a forecast might be valid for a specific region or grid segment. This association is therefore not always a location.
has super-classes
measurement
has usageop only Usagec
has effective periodop exactly 1 intervalc
has creation timedp max 1
has quantiledp max 1
has update ratedp max 1
has sub-classes
Gaussian data pointc, Incentivec
is in domain of
belongs to time seriesop, has quantiledp
is in range of
has costop, has data pointop, has lower boundaryop, has upper boundaryop

Default durationc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/DefaultDuration

The duration of a slot (SHALL be present in case of 'determined slot'). If a slot has a configurable lenght, this element SHALL reflect the currently configured lenght
has super-classes
temporal entityc

Default duration descriptionc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/DefaultDurationDescription

The duration description for the default duration temporal entity
has super-classes
duration descriptionc

Demand Driven Based Control Instructionc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/DDBCInstruction

An Instruction as specified for an Demand Driven Based Control Profile.
has super-classes
Flexibility Instructionc

Demand driven controlc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/DemandDrivenProfile

The Flexibility Profile following the Demand Driven strategy.
has super-classes
Flexibility Profilec
is in domain of
has average demand rate forecastop, has demand rateop

Devicec back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/Device

A specialization of a saref:Device that exposes a power profile with power sequences to the CEM (note that a s4ee:Device can also be called 'power sequence server'). Most of the existing devices can expose at most 1 power profile, but there are special cases in which more than one power profiles can be exposed by the same device. For example, consider the case of a combined fridge-freezer in which there are 2 logical devices (fridge and freezer) combined in 1 physical device. This combined device can expose 2 power profiles, one for the fridge and one for the freezer. A s4ee:Device (e.g. a household appliance or a smart meter) can also receive events about overload warning severity level and related load control commands (LoadControlEventData)
has super-classes
device
receivesop only Load control event datac
Power sourceop min 0
receivesop min 0 Load control event datac
brand namedp max 1
device codedp max 1
device namedp max 1
hardware revision dp max 1
manufacturer descriptiondp max 1
manufacturer labeldp max 1
manufacturer node identificationdp max 1
serial numberdp max 1
software revisiondp max 1
vendor codedp max 1
vendor namedp max 1
has sub-classes
Storagec
is in domain of
has firmware versiondp, performs roleop

Duration uncertaintyc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/DurationUncertainty

The uncertainty of the duration
has super-classes
temporal entityc

Duration uncertainty descriptionc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/DurationUncertaintyDescription

The duration description for the duration uncertainty temporal entity
has super-classes
duration descriptionc

Earliest start timec back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/EarliestStartTime

The earliest possible start time for a power sequence or a slot. Only 'xs:duration' value types SHALL be used to denote a relative time which relates to 'now' as time 0. Note: This element applies to the first repetition of the slot number only.
has super-classes
temporal entityc

Elapsed slot timec back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/ElapsedSlotTime

If state is set to 'running' or 'paused' AND the slot is determined, this element CAN contain the time the slot has already been in 'running' state (this also means the value remains constant during a 'paused' state). Otherwise it SHALL be omitted.
has super-classes
temporal entityc

End Interruption Instructionc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/EndInterruptionInstruction

An Instruction message indicating when an interruption can end.
has super-classes
Interruption Instructionc

End timec back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/EndTime

The endTime of a power sequence. If the value is available, it SHALL be denoted here. Otherwise the element SHALL be omitted. The end time of a slot MAY be stated in this element. The following equation SHALL apply: endTime - startTime = defaultDuration.
has super-classes
temporal entityc

End time duration Descriptionc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/EndTimeDurationDescription

The duration description for the end time duration temporal entities
has super-classes
duration descriptionc

Energyc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/Energy

Energy type and value in a slot (i.e., Energy, EnergyMin, EnergyMax, EnergyExpected, EnergyStandardDeviation, EnergySkewness); or the ResumeEnergyEstimated in a power sequence, i.e., the additional energy the device will consume before resuming its normal operation (after a pause)
has super-classes
energy
has sub-classes
Energy Standard Deviationc, Energy expectedc, Energy maxc, Energy minc, Energy skewnessc, Resume energy estimatedc
is in range of
has energyop

Energy Constraintc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/EnergyConstraint

The energy constraint described in the Allowed Limit Range or Power Limit.
is in domain of
has lower average powerdp, has upper average powerdp

Energy expectedc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/EnergyExpected

A possible type of energy in a slot that represents the expected energy consumption and its value
has super-classes
Energyc

Energy maxc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/EnergyMax

A possible type of energy in a slot that represents the maximum energy consumption and its value
has super-classes
Energyc

Energy minc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/EnergyMin

A possible type of energy in a slot that represents the minimum energy consumption and its value
has super-classes
Energyc

Energy skewnessc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/EnergySkewness

A possible type of energy in a slot that represents the energy skewness and its value
has super-classes
Energyc

Energy Standard Deviationc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/EnergyStandardDeviation

A possible type of energy in a slot that represents the energy standard deviation and its value
has super-classes
Energyc

Event action consumec back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/EventActionConsume

An action type used to express a consume action to be performed as a consequence of an event used to send overload warning severity level and related load control commands to a device (e.g. a household appliance or a smart meter).
is equivalent to
{ Emergency , Increase , Normal , Pause , Reduce , Resume }
has super-classes
Load Control event actionc
has members
Emergencyni, Increaseni, Normalni, Pauseni, Reduceni, Resumeni

Event action producec back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/EventActionProduce

An action type used to express a produce action to be performed as a consequence of an event used to send overload warning severity level and related load control commands to a device (e.g. a household appliance or a smart meter).
is equivalent to
{ Emergency , Increase , Normal , Pause , Reduce , Resume }
has super-classes
Load Control event actionc
has members
Emergencyni, Increaseni, Normalni, Pauseni, Reduceni, Resumeni

Event state consumec back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/EventStateConsume

In the load control, it expresses a consume state of an event used to send overload warning severity level and related load control commands to a device (e.g. a household appliance or a smart meter).
is equivalent to
{ Event accepted , Event cancelled , Event error , Event rejected , Event started , Event stopped }
has super-classes
Load control event state c
has members
Event acceptedni, Event cancelledni, Event errorni, Event rejectedni, Event startedni, Event stoppedni

Event state producec back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/EventStateProduce

In the load control, it expresses a produce state of an event an event used to send overload warning severity level and related load control commands to a device (e.g. a household appliance or a smart meter).
is equivalent to
{ Event accepted , Event cancelled , Event error , Event rejected , Event started , Event stopped }
has super-classes
Load control event state c
has members
Event acceptedni, Event cancelledni, Event errorni, Event rejectedni, Event startedni, Event stoppedni

Fail-safe statec back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/FailsafeState

State that indicates that the device currently is in its Fail-safe state. This means that it has lost its connection to a central energy manager. This may result in the device following stricter power limits.
is in domain of
has failsafe durationdp

Failsafe Power Limitc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/FailsafePowerLimit

In case the communication between a device and the energy manager is interrupted, fail-safe values apply and the device enters fail-safe state until the communication is re-established.
has super-classes
Power Limitc
is in domain of
has failsafe consumption maxop, has failsafe production maxop
is in range of
is limited withop

Fill level target profilec back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/FillLevelTargetProfile

The target profile that a fill rate based control flexibility profile tries to follow.
has super-classes
thingc
is in domain of
has fill level target profile elementop
is in range of
has fill level target profileop

Fill level target profile elementc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/FillLevelTargetProfileElement

A description of the various Elements detailing the Fill Level Target Profile consists.
has super-classes
thingc
is in range of
has fill level target profile elementop

Fill Rate Based Control Instructionc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/FRBCInstruction

A Fill Rate Based Instruction message.
has super-classes
Flexibility Instructionc

Fill rate controlc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/FillRateProfile

A flexibility profile specified through a Fill Rate Based Profile.
has super-classes
Flexibility Profilec
is in domain of
has storageop

Flex offerc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/FlexOffer

It allows to represent a flexibility offer (or schedule) as a combination of multiple time-series, data-points and forecasts. For example, we can create a flexibility offer that includes a time-series ex:T-power of power values, combined with a time-series ex:T-costs of associated costs.
has super-classes
has recipientop only agentc or device
includesop only Data pointc or Flexibility Profilec or Time Seriesc
produced byop only agentc or device
has effective periodop max 1 intervalc
has creation timedp max 1
is in domain of
relates to requestop
is in range of
relates to offerop

Flex requestc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/FlexRequest

The flexibility request
has super-classes
thingc
has effective periodop only intervalc
has recipientop only agentc or device
includesop only Data pointc or Flexibility Profilec or Incentive table based profilec or Time Seriesc
produced byop only agentc or device
has creation timedp only date time
is in range of
relates to requestop

Flexibility Instructionc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/FlexibilityInstruction

The various types of instructions Flexibility Sources can send and/or receive.
has sub-classes
Demand Driven Based Control Instructionc, Fill Rate Based Control Instructionc, Operation Mode Based Control Instructionc, Power Envelop Based Control Instructionc, Power Profile Based Control Instructionc
is in domain of
abnormal conditiondp, has activation planop, has costop, has execution timedp, relates to offerop

Flexibility Profilec back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/FlexibilityProfile

Different control types to describe the energy flexibility that a device has to offer. Charging of an EV for instance, may be controlled by power profile-based control or fill-rate -based control. It is not allowed to mix different control types at the same time, but different control types may be used sequentially. Control Types dictates flexibility instructions. Control Type provides Flexibility options.
has super-classes
profile
has sub-classes
Demand driven controlc, Fill rate controlc, Incentive table based profilec, Operation mode controlc, Power envelope controlc, Power limit profilec

Gaussian data pointc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/GaussianDataPoint

A data point whose quantity is a standard deviation.
has super-classes
Data pointc
has standard deviationdp some decimal
is in domain of
has standard deviationdp

Incentivec back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/Incentive

An Incentive indicates the intersection of a tier with a slot. In this particular combination of slot and tier there are a particular costs to draw this type of energy. For example, drawing power from the grid costs 0.30 euro per kilowatthour during the afternoon, but will only be activated from a lower boundary of 3000W.
has super-classes
Data pointc
is in domain of
has lower boundaryop, has upper boundaryop
is in range of
has incentiveop

Incentive table based profilec back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/IncentiveTableBasedProfile

This flexibility profile describes the usage of an incentive table to describe an incentive type in the form of costs (relative or absolute), CO2 emissions or renewable energy percentage that can be associated to power values (expressed as a time-series of power data-points).
has super-classes
Flexibility Profilec
has scope typeop only Scope Typec
is changeabledp only boolean
requiresUpdatedp only boolean
is in domain of
has scope typeop, has tier incentiveop

Incentive table slotc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/IncentiveTableSlot

This concept describes a slot that belongs to a Incentive Table. Each slot of the Incentive Table consists of a series of (lower) boundaries, each indicating the power at which a change to another incentive takes place. Additionally, each boundary is associated with a IncentiveTableTier.
has super-classes
Slotc

Incentive table tierc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/IncentiveTableTier

This concept specifies a Tier that an Incentive Table consists of. Each Tier indicates through a series of Boundaries the price per kilowatthour this incentive costs. For example, a tier may describe grid power, solar panel power, or surplus power.
has super-classes
Time Seriesc
is in domain of
has incentive typeop

Incentive Typec back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/IncentiveType

In the incentive table, an incentive type is defined in the form of costs (relative or absolute), CO2 emissions or renewable energy percentage.
is in range of
has incentive typeop
has members
Absolute costni, CO2 Emissionni, Relative costni, Renewable energy percentageni

Instruction Statusc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/InstructionStatus

The status an instruction has at a specific moment.
has super-classes
thingc
is in range of
has Instruction Statusop
has members
Abortedni, Acceptedni, Newni, Rejectedni, Revokedni, Startedni, Succeededni

Interruption Instructionc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/InterruptionInstruction

An instruction indicating an interruption to the process.
has super-classes
Power Profile Based Control Instructionc
has sub-classes
End Interruption Instructionc, Start Interruption Instructionc
is in domain of
Has Interruption Start Timedp, has end time Interruptiondp

Latest end timec back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/LatestEndTime

The latest possible end time for a power sequence or a slot. Only 'xs:duration' value types SHALL be used to denote a relative time which relates to 'now' as time 0. Note: This element applies to the first repetition of the slot number only.
has super-classes
temporal entityc

Leakage behaviourc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/LeakageBehaviour

A description of the Leakage Behaviour associated with this Fill Rate Flexibility Profile.
has super-classes
thingc
is in domain of
has leakage behaviour elementop
is in range of
has leakage behaviourop

Leakage behaviour elementc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/LeakageBehaviourElement

An element detailing the leakage behaviour of a storage.
has super-classes
thingc
is in domain of
Leakage Rateop
is in range of
has leakage behaviour elementop

Load Control event actionc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/LoadControlEventAction

An action type used to express the action to be performed as a consequence of an event used to send overload warning severity level and related load control commands to a device (e.g. a household appliance or a smart meter).
has sub-classes
Event action consumec, Event action producec

Load control event datac back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/LoadControlEventData

An event used to send overload warning severity level and related load control commands to a device (e.g. a household appliance or a smart meter).
has super-classes
has time only Time periodc
has deviceop only Devicec
triggers event action consumeop only Event action consumec
triggers event action produceop only Event action producec
has time min 1 Time periodc
has deviceop min 1 Devicec
triggers event action consumeop min 0 Event action consumec
triggers event action produceop min 0 Event action producec
has timestamp only date time
has timestamp min 1
event IDdp min 0

Load control event state c back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/LoadControlEventState

In the load control, it expresses the possible states of an event used to send overload warning severity level and related load control commands to a device (e.g. a household appliance or a smart meter).
has super-classes
Statec
has sub-classes
Event state consumec, Event state producec

Load control state datac back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/LoadControlStateData

The representation of the state of an event used to send overload warning severity level and related load control commands to a device (e.g. a household appliance or a smart meter).
has super-classes
has applied event action consumeop only Event action consumec
has applied event action produceop only Event action producec
has event state consumeop only Event state consumec
has event state produceop only Event state producec
has applied event action consumeop min 0 Event action consumec
has applied event action produceop min 0 Event action producec
has event state consumeop min 0 Event state consumec
has event state produceop min 0 Event state producec
has timestamp only date time
has timestamp min 1
event IDdp min 0

Max activation delayc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/MaxActivationDelay

Maximum delay time between the end of the previous slot and the beginning of the current slot.
has super-classes
temporal entityc

Max anticipationc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/MaxAnticipation

This field allows the anticipation of the phase if (and only if) the previous phase has the energy set to 0 Wh, each unit is a minute.
has super-classes
temporal entityc

Max durationc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/MaxDuration

If a slot has a configurable duration, it SHALL be present and denote the maximum supported configuration. Note: This element applies to the first repetition of the slot number only
has super-classes
temporal entityc

Min durationc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/MinDuration

If a slot has a configurable duration, it SHALL be present and denote the minimum supported configuration. Note: This element applies to the first repetition of the slot number only.
has super-classes
temporal entityc

Nominal Power Limitc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/NominalPowerLimit

A device may have nominal power consumption and/or production values that are defined by the manufacturer and must not be exceeded, so that the power limit must stay within these constraints.
has super-classes
Power Limitc
is in domain of
has nominal consumption Maxop, has nominal production Maxop
is in range of
is protected byop

Number rangec back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/NumberRange

This class describes a range via a datatype property indicating the start of the range and another datatype property indicating the end of the range.
has super-classes
thingc
is in domain of
end of rangeop, start of rangeop
is in range of
Fill Level Rangeop, Fill Rate Levelop, Has Supply Rangeop, has demand rateop, has number rangeop, has running costsop, range boundaryop

Operation Modec back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/OperationMode

A resource manager can declare multiple operation modes for a device. An operation mode is a mode/state that a device can find itself in, that is associated with a specific power value.
has super-classes
state
is in domain of
Has Operation Mode Elementop, Has Supply Rangeop, has costop
is in range of
from operation modeop, has Operation Modesop, has active operation modeop, has previous operation modeop, to state operation modeop

Operation Mode Based Control Instructionc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/OMBCInstruction

An instruction following the Operation Mode Based Profile.
has super-classes
Flexibility Instructionc

Operation mode controlc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/OperationModeProfile

A resource manager can declare multiple operation modes for a device. An operation mode is a mode/state that a device can find itself in, that is associated with a specific power value.
has super-classes
Flexibility Profilec

Operation Mode Elementc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/OperationModeElement

Operation Mode Elements of a Fill Rate Based Control
has super-classes
thingc
is in domain of
has running costsop
is in range of
Has Operation Mode Elementop

Pause duration descriptionc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/PauseDurationDescription

The duration description for the pause duration (max and min) temporal entities
has super-classes
duration descriptionc

Pause duration maxc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/PauseDurationMax

The maximum duration a power sequence can pause after the end of an activity.
has super-classes
temporal entityc

Pause duration minc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/PauseDurationMin

The minimum duration a power sequence can pause after the end of an activity.
has super-classes
temporal entityc

Pause timec back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/PauseTime

The pause time of a power sequence or a slot
has super-classes
temporal entityc

Powerc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/Power

Power type and value in a slot (i.e. power, powerMin, powerMax, powerExpectedValue, powerStandardDeviation, powerSkewness)
has super-classes
power
has sub-classes
Power expected c, Power maxc, Power minc, Power skewnessc, Power standard deviationc

Power constraintc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/PowerConstraint

The actual power constraint contained in the Allowed Limit Range or Power limit.
has super-classes
thingc
is in domain of
Has Consequence Typeop

Power Envelop Based Control Instructionc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/PEBCInstruction

An instruction for the Power Envelope Based Profile.
has super-classes
Flexibility Instructionc

Power Envelopec back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/PowerEnvelope

A specific Power Envelope to be followed by an energy manager
has super-classes
thingc
is in domain of
has envelopeop
is in range of
has power envelopeop, has power envelope elementop

Power Envelope Consequence Typec back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/PowerEnvelopeConsequenceType

The type of consequence of limiting power, which can be Defer or Vanish.
has super-classes
thingc
is in range of
Has Consequence Typeop
has members
Deferni, Vanishni

Power envelope controlc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/PowerEnvelopeProfile

A Flexibility Profile described through a Power Envelope Profile.
has super-classes
Flexibility Profilec
is in domain of
has power envelope elementop

Power Envelope Limit Typec back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/PowerEnvelopeLimitType

An enumeration containing the codelist for Power Envelope Limit Types, which may be Lower limit or Upper limit.
has super-classes
thingc
is in range of
Limit Typeop
has members
Lower Limitni, Upper Limitni

Power expected c back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/PowerExpected

A possible type of power in a slot that represents the expected power consumption and its value
has super-classes
Powerc

Power Limitc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/PowerLimit

A power limit is defined as the maximum value for power consumption and/or production that must not be exceeded by e.g. a (group of) device(s), a building, or also a district.
has super-classes
Allowed limit rangec
is changeabledp only boolean
is obligatorydp only boolean
has sub-classes
Contractual Power Limitc, Failsafe Power Limitc, Nominal Power Limitc
is in domain of
has power limit consumption Maxop, has power limit durationdp, has power limit production Maxop, has power limit stateop, is activedp, is obligatorydp
is in range of
receives power limitop

Power limit profilec back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/PowerLimitProfile

This profile describes the energy flexibility of a device via a set of power limits, following the SPINE documentation
has super-classes
Flexibility Profilec
is in domain of
is bound toop, is limited withop, is protected byop, receives power limitop

Power maxc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/PowerMax

A possible type of power in a slot that represents the maximum power consumption and its value
has super-classes
Powerc

Power minc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/PowerMin

A possible type of power in a slot that represents the minimum power consumption and its value
has super-classes
Powerc

Power planc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/PowerPlan

The Power Plan that an energy manager creates for a device. It contains three timeseries indicating the minimum, average, and maximum respectively.
has super-classes
Time Seriesc
consists of min 3 Time Seriesc
consists of max 3 Time Seriesc

Power Profile Based Control Instructionc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/PPBCInstruction

An instruction for a Power Profile Based Flexibility Profile.
has super-classes
Flexibility Instructionc
has sub-classes
Interruption Instructionc, Schedule Instructionc
is in domain of
Relates to power profileop, Relates to power profile sequenceop, Relates to power profile sequence containerop

Power profile containerc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/PowerSequenceContainer

A container containing the various Power Sequences among which the EMS may choose for the appropriate Power Sequence at a given time.
has super-classes
thingc
is in domain of
has power sequenceop, has power sequence statusop, progressdp
is in range of
Relates to power profile sequence containerop, has power sequence containerop

Power profile controlc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/PowerProfile

A way to model curves of power and energy over time, which also provides definitions for the modelling of power scheduling including alternative plans. With a PowerProfile, a device (or power sequences server) exposes the power sequences that are potentially relevant for the CEM (or power sequences client).
has super-classes
profile
consists of only Alternatives groupc
belongs toop only Devicec
consists of min 0 Alternatives groupc
belongs toop exactly 1 Devicec
alternatives countdp exactly 1
node remote controllabledp exactly 1
supports reselectiondp exactly 1
supports single slot scheduling onlydp exactly 1
total sequences count maxdp exactly 1
is in domain of
has power sequence containerop
is in range of
Relates to power profileop

Power rangec back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/PowerRange

A class describing a power range, containing a start of range, an end of range, and a saref:Property indicating the type of power involved.
has super-classes
thingc
is in domain of
has number rangeop
is in range of
has power rangesop

Power sequencec back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/PowerSequence

The specification of a task, such as wash or tumble dry, according to user preferences and/or manufacturer's settings for a certain device. It is the most 'coarse' view, a power sequence can represent all single steps of a whole task,where the single steps are represented by slots. If the power sequence is pausable by the bound power sequences client, the property 'saref:isInterruptionPossible' SHALL be present and set to true. Otherwise it SHALL be omitted. If the power sequence is stoppable by the bound power sequences client, the property 'saref:isFlexible' SHALL be present and set to true. Otherwise it SHALL be omitted.
has super-classes
thingc
consists of only Slotc
has price only Resume cost estimatedc
has state only Power sequence statec
belongs toop only Alternatives groupc
has energyop only Resume energy estimatedc
consists of min 1 Slotc
has state min 1 Power sequence statec
has time min 1 Start timec
has value sourceop min 0
belongs toop exactly 1 Alternatives groupc
has price max 1 Resume cost estimatedc
has time max 1 Active duration maxc
has time max 1 Active duration minc
has time max 1 Active duration sum maxc
has time max 1 Active duration sum minc
has time max 1 Earliest start timec
has time max 1 Elapsed slot timec
has time max 1 End timec
has time max 1 Latest end timec
has time max 1 Pause duration maxc
has time max 1 Pause duration minc
has time max 1 Remaining slot timec
has energyop max 1 Resume energy estimatedc
task identifierdp min 0
sequence IDdp exactly 1
sequence remote controllabledp exactly 1
has description max 1
active repetition numberdp max 1
active slot numberdp max 1
cheapestdp max 1
greenestdp max 1
is pausabledp max 1
is stoppabledp max 1
max cycles per daydp max 1
repetition totaldp max 1
is in domain of
Pause before Maximumdp, has power sequence elementop, is interruptibledp, max pause beforedp
is in range of
Relates to power profile sequenceop, has power sequenceop

Power sequence elementc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/PowerSequenceElement

An element of a power sequence, roughly equivalent to slots in the existing S4ener.
has super-classes
thingc
is in range of
has power sequence elementop

Power sequence statec back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/PowerSequenceState

The current state of the power sequence. It can assume one of the values 'running', 'paused', 'scheduled', 'scheduled paused', 'pending', 'inactive', 'completed', or 'invalid'.
has super-classes
Statec
has members
Completedni, Inactiveni, Invalidni, Pausedni, Pendingni, Runningni, Scheduledni, Scheduled pausedni

Power sequence statusc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/PowerSequenceStatus

A codelist for the various Power Sequence statuses.
has super-classes
thingc
is in range of
has power sequence statusop
has members
Abortedni, EXECUTINGni, Finishedni, Interruptedni, NotScheduledni

Power skewnessc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/PowerSkewness

A possible type of power in a slot that represents the power skewness and its value
has super-classes
Powerc

Power sourcec back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/PowerSource

Indicates the power source of a device. Possible values are e.g. mainsSinglePhase or battery
has super-classes
thingc
is in range of
Power sourceop
has members
Battery power sourceni, DC Power sourceni, Mains single phaseni, Mains3Phaseni

Power standard deviationc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/PowerStandardDeviation

A possible type of power in a slot that represents the power standard deviation and its value
has super-classes
Powerc

Remaining pause timec back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/RemainingPauseTime

The duration that the current slot (s4ee:activeSlotNumber) permits being paused. This element SHALL ONLY be present if the power sequence is interruptible. Otherwise, it SHALL be omitted. In case the power sequence is interruptible the following rules apply: If the element is absent this means there is no explicit pause duration restriction for the current slot; a value of 0s denoted the slot does not permit being paused.
has super-classes
temporal entityc

Remaining slot timec back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/RemainingSlotTime

If state is set to 'running' or 'paused' AND the slot is determined, this element SHALL contain the time the slot still needs to be in 'running' state (this also means the value remains constant during a 'paused' state). Otherwise it SHALL be omitted.
has super-classes
temporal entityc

Resume cost estimatedc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/ResumeCostEstimated

In a power sequence the additional costs for the resumption of a device to its normal operation (after a pause).
has super-classes
price

Resume energy estimatedc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/ResumeEnergyEstimated

In a power sequence, the additional energy the device will consume before resuming its normal operation (after a pause). This is only an estimated value which will not be added to the value stated in any slot value information.
has super-classes
Energyc

Rolec back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/Role

A codelist containing the various roles a device can take: producer, consumer, and storage.
has super-classes
thingc
is in domain of
Uses commodityop, role typeop
is in range of
performs roleop

Role Typec back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/RoleType

An enumeration containing the various roles a device can take up: consumer, producer, or storage.
is in range of
role typeop
has members
Energy Consumerni, Energy Producerni, Energy Storageni

Schedule Instructionc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/ScheduleInstruction

Schedule instruction for a power profile flexibility profile.
has super-classes
Power Profile Based Control Instructionc

Scope Typec back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/ScopeType

An incentive table may additionally define a scope type to indicate whether it is a preliminary or committed version.
is in range of
has scope typeop
has members
Committedni, Preliminaryni

Slotc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/Slot

The single steps of a power sequence are represented by slots. A slot is associated with a slot number (while a power sequence is associated with a power sequence identifier). The slot numbers of two power sequences should be considered independent from each other, i.e., slot number 7 of sequence 1 describes a different slot than slot number 7 of sequence 2. Therefore a slot is only uniquely identified in combination with a sequence ID.
has super-classes
has time only time
belongs toop only Power sequencec
has energy value typeop only Energyc
has power value typeop only Powerc
has value typeop min 1
belongs toop exactly 1 Power sequencec
has time max 1 Default durationc
has time max 1 Duration uncertaintyc
has time max 1 Earliest start timec
has time max 1 End timec
has time max 1 Latest end timec
has time max 1 Max durationc
has time max 1 Min durationc
has time max 1 Remaining pause timec
has time max 1 Start timec
slot numberdp exactly 1
has description max 1
optional slotdp max 1
slot activateddp max 1
has sub-classes
Incentive table slotc
is in domain of
has slot valueop

Slot time duration descriptionc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/SlotTimeDurationDescription

The duration description for the slot time duration temporal entities
has super-classes
duration descriptionc

Start Interruption Instructionc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/StartInterruptionInstruction

An instruction or message indicating the start of an interruption.
has super-classes
Interruption Instructionc

Start timec back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/StartTime

The startTime of a power sequence or slot. SHALL be present
has super-classes
temporal entityc

Start time duration descriptionc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/StartTimeDurationDescription

The duration description for the start time duration temporal entities
has super-classes
duration descriptionc

Statec back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/State

An entity that represents the possible states in SAREF4EE
has super-classes
state
has sub-classes
Load control event state c, Power sequence statec

Storagec back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/Storage

storage device which is the main component of Fill Rate Based Control type.). In the context of flexibility control and instructuons, a device shall be able to inform the CEM about its fill level, a measure of how full the storage is, and the lower and upper boundaries that the fill level should remain within.
has super-classes
thingc
Devicec
is in domain of
has fill level target profileop, has leakage behaviourop, present fill levelop
is in range of
has storageop

Time periodc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/TimePeriod

The time period associated with load control event data
has super-classes
temporal entityc

Time period duration descriptionc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/TimePeriodDurationDescription

The duration description for the time period duration temporal entities
has super-classes
duration descriptionc

Time Seriesc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/TimeSeries

An ordered sequence of data points of a quantity observed at spaced time intervals is referred to as a time series. Time series can be a result of prediction algorithm.
has super-classes
has effective periodop only intervalc
has usageop only Usagec
has data pointop min 0 Data pointc
has creation timedp max 1
has temporal resolutiondp max 1
has update ratedp max 1
has sub-classes
Incentive table tierc, Power planc
is in domain of
has data pointop
is in range of
Has Usage Forecastop, belongs to time seriesop, has activation planop, has average demand rate forecastop, has envelopeop

Timerc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/Timer

A timer for time-based operation mode and transition constraints.
has super-classes
thingc
is in domain of
is finished atdp
is in range of
Has Timerop, Starts Timerop, is blocked byop

Transitionc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/Transition

Possible transitions to switch from one Operation Mode to another or to set new parameters.
has super-classes
thingc
is in domain of
Starts Timerop, Transition Durationdp, from operation modeop, has transition costsdp, is blocked byop, to state operation modeop
is in range of
has transitionop

Usagec back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/Usage

The usage of a datapoint, time series or message.
is in range of
has usageop
has members
Averageni, Baselineni, Consumptionni, Downflexni, Lower Limitni, Maximumni, Minimumni, Productionni, Setpointni, Upflexni, Upper Limitni

Value sourcec back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/ValueSource

Indicates the source (origin/foundation) of the measurement forecasted values for a power sequence. If absent, the source is undefined. Remark: This element shall express the reliability of the forecast.
has super-classes
thingc
is in range of
has value sourceop
has members
Calculatedni, Empiricalni, Measuredni

Value tendencyc back to ToC or Class ToC

IRI: https://saref.etsi.org/saref4ener/ValueTendency

This type indicates a codelist for the s4ener:valueTendency property about whether the tendency of a measurement is rising, stable or falling.
has super-classes
thingc
is in range of
value tendencyop
has members
Fallingni, Risingni, Stableni

Object Properties

allowed limit rangeop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/allowedLimitRange

This property indicates the various AllowedLimitRanges or PowerLimits that this PowerConstraint object consists of.

belongs toop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/belongsTo

A relationship identifying the ownership of an entity. In particular, a slot belongs to a power sequence, a power sequence belongs to an alternative, an alternative belongs to a power profile, a power profile belongs to a device.

belongs to time seriesop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/belongsToTimeSeries

The relationship that connects a data point to a time series.
has domain
Data pointc
has range
Time Seriesc
is inverse of
has data pointop

end of rangeop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/endOfRange

This property indicates the end of a number range.
has domain
Number rangec
has range
measurement

Fill Level Rangeop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasFillLevelRange

The range of the fill level for which this FRBC.OperationModeElement applies. If this concept is applied on a Storage it indicated the range in which a storage should remain.

Fill Rate Levelop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/fillRate

Indicates the change in fill_level per second. The lower_boundary of the NumberRange is associated with an operation_mode_factor of 0, the upper_boundary is associated with an operation_mode_factor of 1.

from operation modeop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/fromOperationMode

ID of the OperationMode (exact type differs per ControlType) that should be switched from.
has domain
Transitionc
has range
Operation Modec

has activation planop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasActivationPlan

The relationship between the s4ener:FlexibilityInstruction and s4ener:TimeSeries.

has active operation modeop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasActiveOperationMode

A reference to the OperationMode that is presently active
has domain
actuator or Operation Modec
has range
Operation Modec

has applied event action consumeop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasAppliedEventActionConsume

A relationship between the state of a load control event consume and the action to be performed as a consequence of this event.

has applied event action produceop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasAppliedEventActionProduce

A relationship between the state of a load control event produce and the action to be performed as a consequence of this event.

has average demand rate forecastop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasDemandRateForecast

This property relates a Demand Driven Profile to a TimeSeries object that indicates a forecast of the average demand rate.

has connectionop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasConnection

In the Remote Network Management (RemoteNWM) use case, a relationship between a node in a network (i.e., a s4ee:Device) and its connections (i.e., a s4ee:DeviceConnections). The same s4ee:Device (or node) can have multiple device connections as it can be connected to several networks at the same time.

Has Consequence Typeop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasConsequenceType

The consequence type associated with this Power Constraint, which can be Defer or Vanish.

has constraintsop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasConstraints

This property relates a Power Envelop Instruction or Profile to the constraints it needs to follow. There are two types of constraints modelled: Power constraints and energy constraints.

has contractual consumption Maxop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasContractualConsumptionMax

The relationship between the contractual power limit and the value indicating the max limit consumption.
has super-properties
has power limit consumption Maxop
has domain
Contractual Power Limitc
has range
measurement

has contractual production Maxop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasContractualProductionMax

The relationship between the contractual power limit and the value indicating the max limit production.
has super-properties
has power limit production Maxop
has domain
Contractual Power Limitc
has range
measurement

has costop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasCost

The relationship between the s4ener:FlexibilityInstruction and s4ener:DataPoint

has data pointop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasDataPoint

This relationship connects a time series to data point.
has domain
Time Seriesc
has range
Data pointc
is inverse of
belongs to time seriesop

has demand rateop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasDemandRate

The present demand rate that needs to be satisfied by the system

has deviceop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasDevice

A relationship between a load control event (used to send overload warning severity level and related load control commands) and the device interested by this event.

has effective periodop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasEffectivePeriod

This connects to the temporal entity which describes when (time interval) the quantity of this data point was, is, or will be in effect. This is the time interval which is covered by the forecast. This should be equivalent to the time interval covered by the time-series that express the forecast. *A potential application of SHACL?*
has range
intervalc

has energyop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasEnergy

A relationship between a power sequence and its energy (in terms of value and unit of measure)
has range
Energyc

has energy value typeop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasEnergyValueType

A relationship representing an energy value type
has super-properties
has value typeop

has envelopeop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasEnvelope

This property relates a Power Envelope to the Timeseries object that describes the envelope
has domain
Power Envelopec
has range
Time Seriesc

has event state consumeop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasEventStateConsume

A relationship between the specification of the state of a load control event consume and the value that this state can assume.
has super-properties
has state

has event state produceop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasEventStateProduce

A relationship between the specification of the state of a load control event produce and the value that this state can assume.
has super-properties
has state

has expressionop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasExpression

A relationship between an appliance parameter compatibility action and the associated expressions

has failsafe consumption maxop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasFailsafeConsumptionMax

The relationship between the failsafe power limit and the value indicating its consumption.
has super-properties
has power limit consumption Maxop
has domain
Failsafe Power Limitc
has range
measurement

has failsafe production maxop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasFailsafeProductionMax

The relationship between the failsafe power limit and the value indicating its production.
has super-properties
has power limit production Maxop
has domain
Failsafe Power Limitc
has range
measurement

has fill level target profileop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasFillLevelTargetProfile

The Fill Level Target Profile of the storage that the current Fill Rate Profile tries to accomodate for. NB. This cannot be modelled as a TimeSeries, since the x-axis is not time.

has fill level target profile elementop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasFillLevelTargetProfileElement

The various Fill Level Target Profile Elements detailing the Fill Level Target Profile that the current Fill Level Based Profile tries to accomodate for.

has functionop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasFunction

A relationship identifying the functions performed by an actuator level and an actuator switch

has incentiveop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasIncentive

This property relates an IncentiveTable element, such as an IncentiveTableSlot or an IncentiveTableTier to the boundaries that it consists of.

has incentive typeop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasIncentiveType

The relationship between the tier and its incentive type

has Instruction Statusop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasInstructionStatus

Present status of this instruction.

has leakage behaviourop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasLeakageBehaviour

The Leakage Behaviour associated with this storage.
has domain
Storagec
has range
Leakage behaviourc

has leakage behaviour elementop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasLeakageBehaviourElement

This property relates the LeakageBehaviour description to the LeakageBehaviourElements indicating the detailed description.

has lower boundaryop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasLowerBoundary

This property relates an IncentiveTableBoundary to the datapoint describing its lower boundary or starting point at which this boundary becomes active.
has domain
Incentivec
has range
Data pointc

has messaging typeop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasMessagingType

The messaging type associated with this element.

has nominal consumption Maxop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasNominalConsumption

The relationship between the nominal power limit and the value indicating the max limit consumption.
has super-properties
has power limit consumption Maxop
has domain
Nominal Power Limitc
has range
measurement

has nominal production Maxop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasNominalProduction

The relationship between the nominal power limit and the value indicating the max limit production.
has super-properties
has power limit production Maxop
has domain
Nominal Power Limitc
has range
measurement

has number rangeop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasNumberRange

This property provides the association between a power range and its number range.
has domain
Power rangec
has range
Number rangec

Has Operation Mode Elementop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasOperationModeElement

List of OperationModeElements, which describe the properties of this FRBC.OperationMode depending on the fill_level. The fill_level_ranges of the items in the Array must be contiguous.

has Operation Modesop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasOperationMode

This property indicates the s4ener:OperationMode inidicated by this Actuator, Instruction, or OperationModeProfile. The SAREF4ENER extension expects the following classes to be used as domain: - saref:Actuator - s4ener:FRBCInstruction - s4ener:DDBCInstruction - s4ener:OMBCInstruction - s4ener:OperationModeProfile
has range
Operation Modec

has power envelopeop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasPowerEnvelope

The PEBC.PowerEnvelope(s) that should be followed by the Resource Manager. There shall be at least one PEBC.PowerEnvelope, but at most one PEBC.PowerEnvelope for each CommodityQuantity.

has power envelope elementop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasPowerEnvelopeElement

This property relates a PowerEnvelopeProfile to the various specific PowerEnvelops contained in the profile.

has power limit consumption Maxop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasPowerLimitConsumptionMax

The relationship between the power limit and the value indicating the max limit consumption.

has power limit production Maxop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasPowerLimitProductionMax

The relationship between the power limit and the value indicating the max limit production.

has power limit stateop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasPowerLimitState

The relationship between the power limit state and its state (active/ inactive).
has domain
Power Limitc

has power rangesop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasPowerRange

The power produced or consumed by this operation mode. The start of each PowerRange is associated with an operation_mode_factor of 0, the end is associated with an operation_mode_factor of 1. In the array there must be at least one PowerRange, and at most one PowerRange per CommodityQuantity.

has power sequenceop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasPowerSequence

The various Sequences contained in a Power Sequence Container among which the EMS can choose the proper PowerSequence for the current energy demands.

has power sequence containerop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasPowerSequenceContainer

The various power sequence containers contained within an S2 Power Profile. The containers have to executed one after the other. Each container contains various Power Sequence anong which the EMS can choose the appropriate Power Sequence for the current energy demands.

has power sequence elementop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasPowerSequenceElement

A connection between the Power Sequence and the elements (or Slots) describing the exact contents.

has power sequence statusop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasPowerSequenceStatus

This property indicates the current status of this Power Sequence.

has power value typeop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasPowerValueType

A relationship representing a power value type
has super-properties
has value typeop

has previous operation modeop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasPreviousOperationMode

The previous operation mode this device was in
has domain
actuator or Operation Modec
has range
Operation Modec

has recipientop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasRecipient

This property can be used to connect a flexibility offer or/and flexibility request to a foaf:agent or saref:Device.

has running costsop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasRunningCosts

Additional costs per second (e.g. wear, services) associated with this operation mode in the currency defined by the ResourceManagerDetails , excluding the commodity cost. The range is expressing uncertainty and is not linked to the operation_mode_factor.

has scope typeop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasScopeType

The relationship between the incentive table and the scope type

has slot valueop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasSlotValue

This property is intended to specify the power or energy value of a slot in a power sequence as part of a power profile. This property is a suggestion to be added in Saref4Energy v2.
has domain
Slotc
has range
measurement
relates to property min 1

has storageop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasStorage

The storage regulated by the related Fill Rate Profile.
has domain
Fill rate controlc
has range
Storagec

Has Supply Rangeop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasSupplyRange

The SupplyRange this OperationMode of a Demand Driven Profile can deliver for the CEM to match the DemandRate. The start of the NumberRange is associated with an operation_mode_factor of 0, the end is associated with an operation_mode_factor of 1.
has domain
Operation Modec
has range
Number rangec

has tier incentiveop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasTier

The relationship between the incentive table and the tiers it consists of

Has Timerop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasTimer

The set of timers that are available in this Actuator or OperationModeProfile
has domain
actuator or Operation mode controlc
has range
Timerc

has transitionop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasTransition

The transitions between various saref:States or s4ener:OperationModes that either the Actuator or the OperationModeProfile can support.
has domain
actuator or Operation mode controlc
has range
Transitionc

has upper boundaryop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasUpperBoundary

This property relates a boundary to its upper boundary or the value at which this incentive becomes inactive. This value is optional, because the upper boundary can be inferred from the lower boundary of the next boundary.
has domain
Incentivec
has range
Data pointc

has usageop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasUsage

This property provides the possibility to add some additional information about the usage of a data-point or time-series. For example, a data point or time series can be used as an upper limit, lower limit or a baseline, a maximum versus minimum value, or a consumption versus a production value.
has range
Usagec

Has Usage Forecastop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasUsageForecast

Indicates the usage forecast that may be relevant to decide the energy flexibility strategy following a specific flexibility profile, specifically a fill rate based profile or incentive table. In SAREF4ENER this property is intended to be applied on an s4ener:FlexibilityProfile.
has range
Time Seriesc

has value sourceop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasValueSource

Indicates the source (origin/foundation) of the measurement forecasted values for a power sequence. If absent, the source is undefined. Remark: This element shall express the reliability of the forecast.
has range
Value sourcec

has value typeop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasValueType

A relation representing the value type of an entity

includesop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/includes

This property can be used to connect the flexibility offer and/or flexibility request to the flexibility profile. Additionally, it can be used to specify the s4ener:datapoint, s4ener:timeseries and ic-fc:forecast included in the flexibility offer and/or flexibility request.

is actuated byop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/isActuatedBy

A reference to an (external) actuator that can potentially activate this profile or where the instruction originates from.

is blocked byop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/isBlockedBy

The Timers that block this Transition from initiating while at least one of these Timers is not yet finished
has domain
Transitionc
has range
Timerc

is bound toop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/isBoundTo

The relationship between a device and its contractual power limit

is limited withop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/isLimitedWith

The relationship between device and failsafe power limit

is protected byop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/isProtectedBy

The relationship between the device and the nominal power limit

Leakage Rateop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/leakageRate

Indicates how fast the momentary fill level will decrease per second due to leakage within the given range of the fill level.
has domain
Leakage behaviour elementc
has range
measurement

Limit Typeop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/limitType

Indicates if this ranges applies to the upper limit or the lower limit.

performs roleop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasRole

Each Resource Manager provides one or more energy Roles
has domain
Devicec
has range
Rolec

Power sourceop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasPowerSource

Indicates the power source of a device. Possible values are e.g. mainsSinglePhase or battery
has range
Power sourcec

present fill levelop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/presentFillLevel

A saref:Measurement with a percentage value indicating the fill level of the storage.
has domain
Storagec
has range
measurement

produced byop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/producedBy

A relation between an entity (datapoint, message, timeseries, instruction) that has been produced by a device or other agent. In the context of SAREF4ENER this property is intended for s4ener:DataPoint, s4ener:TimeSeries, and the various types of flexibility instructions, FlexOffers and FlexRequests.
has range
agentc or device

range boundaryop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/rangeBoundary

Boundaries of the power range of this PEBC.AllowedLimitRange. The CEM is allowed to choose values within this range for the power envelope for the limit as described in limit_type. The start of the range shall be smaller or equal than the end of the range.

receivesop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/receives

A relationship between a device (e.g., an appliance or a smart meter) and a load control event

receives power limitop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/receivesPowerLimit

The relationship between a power limit profile and the power limit it has received for its device to follow
has domain
Power limit profilec
has range
Power Limitc

relates to commodity quantityop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/relatesToCommodityQuantity

Relates the classes to the various commodity quantities introduced by the S2 standard. In the SAREF4ENER extension this property is intended for the following: - s4ener:PowerRange - s4ener:AllowedLimitRange - s4ener:EnergyConstraint - s4ener:PowerEnvelope

relates to offerop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/relatesToOffer

The relationship between the s4ener:FlexibilityInstruction and the flexibility offer.

Relates to power profileop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/relatesToPowerProfile

ID of the PPBC.PowerProfileDefinition of which the PPBC.PowerSequence is being selected and scheduled by the CEM.

Relates to power profile sequenceop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/relatesToPowerProfileSequence

ID of the PPBC.PowerSequence that is being selected and scheduled by the CEM.

Relates to power profile sequence containerop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/relatesToPowerProfileSequenceContainer

ID of the PPBC.PowerSequnceContainer of which the PPBC.PowerSequence is being selected and scheduled by the CEM.

relates to requestop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/relatesToRequest

The relationship between the flexibility offer and flexibility request
has domain
Flex offerc
has range
Flex requestc

role typeop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasRoleType

The type of this specific role
has domain
Rolec
has range
Role Typec

start of rangeop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/startOfRange

This property indicates the start of a number range.
has domain
Number rangec
has range
measurement

Starts Timerop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/startsTimer

List of IDs of Timers that will be (re)started when this transition is initiated
has domain
Transitionc
has range
Timerc

to state operation modeop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/toOperationMode

ID of the OperationMode (exact type differs per ControlType) that will be switched to.
has domain
Transitionc
has range
Operation Modec

triggers event action consumeop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/triggersEventActionConsume

A relationship between a load control event and the consume action triggered by this event

triggers event action produceop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/triggersEventActionProduce

A relationship between a load control event and the produce action triggered by this event

Uses commodityop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/hasCommodity

An indication of which commodity this Role is a consumer, producer, or storer of.
has domain
Rolec
has range
commodity

value tendencyop back to ToC or Object Property ToC

IRI: https://saref.etsi.org/saref4ener/valueTendency

Indicates whether the tendency of a measurement is rising, stable, or falling.
has range
Value tendencyc

Data Properties

abnormal conditiondp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/abnormalCondition

Indicates if this is an instruction during an abnormal condition
has domain
Flexibility Instructionc
has range
boolean

Abnormal Condition Onlydp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/abnormalConditionOnly

Indicates if this element can only be used during an abnormal condition. In SAREF4ENER this property is intended to be used on the following properties: - s4ener:OperationMode - s4ener:Transition - s4ener:AllowedLimitRange - s4ener:PowerSequence
has range
boolean

activate slotdp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/activateSlot

Indicates whether a slot is used (activateSlot = true) or not (activateSlot = false). SHALL be present if a slot is optional (i.e., the property s4ee:optionalSlot is TRUE), otherwise SHALL be absent (i.e. in case the slot is mandatory).
has range
boolean

activation delay maxdp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/hasActivationDelayMax

Maximum delay time between the end of the previous slot and the beginning of the current slot. This property is suggested to be added to SAREF4Ener_v2 to replace the time:TemporalEntity and/or time:DurationDescription.
has super-properties
duration in xsd dp
has range
duration

active duration maxdp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/hasActiveDurationMax

The active maximum duration a power sequence can run without interruption. This property is suggested to be added to SAREF4Ener_v2 to replace the time:TemporalEntity and/or time:DurationDescription.
has super-properties
duration in xsd dp
has range
duration

active duration mindp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/hasActiveDurationMin

The active mininum duration a power sequence can run without interruption. This property is suggested to be added to SAREF4Ener_v2 to replace the time:TemporalEntity and/or time:DurationDescription.
has super-properties
duration in xsd dp
has range
duration

active duration sum maxdp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/hasActiveDurationSumMax

The active maximum duration a power sequence can run in total (summation of all active times). This property is suggested to be added to SAREF4Ener_v2 to replace the time:TemporalEntity and/or time:DurationDescription.
has super-properties
duration in xsd dp
has range
duration

active duration sum mindp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/hasActiveDurationSumMin

The active minimum duration a power sequence must run in total (summation of all active times). This property is suggested to be added to SAREF4Ener_v2 to replace the time:TemporalEntity and/or time:DurationDescription.
has super-properties
duration in xsd dp
has range
duration

active repetition numberdp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/activeRepetitionNumber

Indicates the current repetition of the sequence of slots. SHALL be present if a power sequence can repeat its sequence of slots (i.e., if s4ee:repetitionTotal is present and has a value > 1). Otherwise, it SHALL be absent.
has range
unsigned int

active slot numberdp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/activeSlotNumber

Indicates the currently active slot number, if the power sequence state is set to 'running' or 'paused'. Otherwise it SHALL be omitted.
has range
unsigned int

alternatives countdp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/alternativesCount

Indicates the number of alternatives groups provided by a power profile
has range
integer

alternatives group IDdp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/alternativesGroupID

The endpoint-wide unique identifier for the alternatives group instances provided by a power profile
has range
integer

brand namedp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/brandName

Provides the name of the brand of a device. Useful where the name of the brand and the vendor differs.
has range
string

cheapestdp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/cheapest

Indicates whether a power sequence applies a configuration that minimises the user's energy bill (if set to TRUE). MAY be present. Absence of this element is equal to the presence with value FALSE.
has range
boolean

delaydp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/hasActivationDelay

The scheduled activation delay for a slot. This property is suggested to be added in SAREF4Ener_v2 to replace the subclasses of time:TemporalEntity and/or time:DurationDescription
has super-properties
duration in xsd dp
has range
duration

device codedp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/deviceCode

Provides a device code for the device as defined by the manufacturer.
has range
string

device namedp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/deviceName

Provides the name of the device as defined by the manufacturer.
has range
string

duration defaultdp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/hasDurationDefault

The duration of a slot (SHALL be present in case of 'determined slot'). If a slot has a configurable lenght, this element SHALL reflect the currently configured lenght This property is suggested to be added to SAREF4Ener_v2 to replace the time:TemporalEntity and/or time:DurationDescription.
has super-properties
duration in xsd dp
has range
duration

duration in xsd dp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/hasDuration

This property is added to the time:DurationDescription class to allow to express time duration also as xsd:duration. This is necessary because in the EEBus/E@h model time is always expressed as xsd:duration. We use this property to express the following time information in the EEBus/E@h model: - the startTime of the power sequence (in the PowerSequence class). SHALL be present - the endTime of the power sequence (in the PowerSequence class). If the value is available, it SHALL be denoted here. Otherwise the element SHALL be omitted. - the startTime of measurement as absolute or relative value (in the Measurement class). - the endTime of measurement as absolute or relative value (in the Measurement class). The duration is expected to be described as in xsd:duration

duration minimumdp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/hasDurationMin

The minimum duration for some component This property is suggested to be added in SAREF4ENER_V2
has super-properties
duration in xsd dp
has range
duration

end timedp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/hasEndTime

The endTime of a power sequence. If the value is available, it SHALL be denoted here. Otherwise the element SHALL be omitted. The end time of a slot MAY be stated in this element. The following equation SHALL apply: endTime - startTime = defaultDuration.
has super-properties
has timestamp
has range
duration

event IDdp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/eventID

Used in the Demand Response use case to identify an event
has range
unsigned int

greenestdp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/greenest

Indicates whether a power sequence optimises the configuration towards the maximum availability of renewable energy (if set to TRUE). MAY be present. Absence of this element is equal to the presence with value FALSE.
has range
boolean

hardware revision dp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/hardwareRevision

Indicates the hardware revision of the device as defined by the manufacturer.
has range
string

has creation timedp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/hasCreationTime

The time instant that defines the creation time of a data point or quantity or forecast or similar entities. This is not the same as the time at which the quantity is in effect. For example, if a temperature is forecasted today at 12:30 (creation time of the forecast) for the following day at 14:45 (time when the temperature is expected to be in effect), the this instant should be 12:30 of today. A creation time (instant). This is the point in time when the data point was created, which is not necessarily the time for which it is valid. In the case of soft-sensors or forecasters, a data point might have been created ahead of time, in the case of a direcet measurement a data point might created at its time of validity (or at the end of its validity time interval) and in the case of an archived value the data point might have been created after the fact.
has range
date time stamp

has earliest start timedp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/hasEarliestStartTime

The earliest possible start time for a power sequence or a slot. Only 'xs:duration' value types SHALL be used to denote a relative time which relates to 'now' as time 0. Note: This element applies to the first repetition of the slot number only. This property is suggested to be added to SAREF4Ener_v2 to replace the time:TemporalEntity and/or time:DurationDescription.
has super-properties
has timestamp
has range
date time stamp

has end time Interruptiondp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/hasInterruptionEndTime

The end time included in an Interruption Instruction message indicating when the interruption should end.
has super-properties
has timestamp
has domain
Interruption Instructionc
has range
date time stamp

has execution timedp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/hasExecutionTime

Start time of the instruction
has super-properties
has timestamp
has domain
Flexibility Instructionc
has range
date time stamp

has failsafe durationdp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/hasFailsafeDuration

The relationship between the failsafe power limit and its duration. This property indicates the minimum duration the fail safe state will take once a device has entered that state.
has super-properties
duration in xsd dp
has domain
Fail-safe statec
has range
duration

has firmware versiondp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/firmwareVersion

Version identifier of the firmware used in the device (provided by the manufacturer)
has domain
Devicec
has range
string

has indexdp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/hasIndex

Gives the index for elements that are an array in the S2 specification. Can be used regularly as well as in RDF* manner on properties.
has range
integer

Has Interruption Start Timedp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/hasInterruptionStartTime

The start time included in an Interruption Instruction message indicating when the interruption should start.
has super-properties
has timestamp
has domain
Interruption Instructionc
has range
date time stamp

has latest end timedp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/hasLatestEndTime

The latest possible end time for a power sequence or a slot. Only 'xs:duration' value types SHALL be used to denote a relative time which relates to 'now' as time 0. Note: This element applies to the first repetition of the slot number only. This property is suggested to be added to SAREF4Ener_v2 to replace the time:TemporalEntity and/or time:DurationDescription.
has super-properties
has timestamp

has lower average powerdp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/hasLowerAveragePower

The lower average power associated with this Energy constraint.
has domain
Energy Constraintc
has range
integer

Has Namedp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/hasName

Human readable name given by user
has range
string

Has Operation Mode Factordp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/hasOperationModeFactor

The number indicates the factor with which the FRBC.OperationMode or OMBC.OperationMode is usedconfigured. The factor should be greater than or equal than 0 and less or equal to 1. Within the SAREF4ENER extension, this property is to be used on the following classes: - s4ener:OMBCInstruction - s4ener:OperationMode - saref:Actuator - s4ener:FRBCInstruction - s4ener:DDBCInstruction
has range
decimal

has power limit durationdp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/hasPowerLimitDuration

The relationship between the power limit and its duration. Power limit may come with a time period of validity based on duration
has super-properties
duration in xsd dp
has domain
Power Limitc
has range
duration

has quantiledp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/hasQuantile

Used to define a quantile for example on a data point of a quantile time series. The quantile must be a ratio, usually a percentage. In a quantile forecast the hasQuantile property cannot be empty
has domain
Data pointc
has range
decimal

has standard deviationdp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/hasStandardDeviation

Adds a standard deviation to a data point.
has domain
Gaussian data pointc
has range
decimal

has start timedp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/hasStartTime

The startTime of a power sequence or slot. SHALL be present
has super-properties
has timestamp
has range
date time stamp

has temporal resolutiondp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/hasTemporalResolution

The resolution is the distance between two measurement time-stapms. This only makes sense if the measurements are equidistant.
has range
duration

has transition costsdp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/hasTransitionCosts

Absolute costs for going through this Transition in the currency as described in the ResourceManagerDetails.
has domain
Transitionc
has range
decimal

has update ratedp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/hasUpdateRate

The rate at which a data point or time-series or forecast or other data entity is being updated. If the time series gets regularly updated, then the time between two updates can be recorded here.
has range
duration

has upper average powerdp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/hasUpperAveragePower

The upper average power of an Energy constraint of a Power Envelope profile.
has domain
Energy Constraintc
has range
integer

has valuedp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/hasValue

Power value expressed in the unit associated with the CommodityQuantity of the Power Value.
has range
decimal

is activedp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/isActive

Indicates whether the power limit is currently active
has domain
Power Limitc
has range
boolean

is changeabledp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/isChangeable

A relationship indicating that this element can be changed by its operator. The boolean value indicates whether it is indeed changeable. In the SAREF4ENER extension this property is intended for PowerLimits and IncentiveTable elements, such as the IncentivebasedProfile, IncentiveTableSlot, and the IncentiveTableTier.
has range
boolean

is finished atdp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/isFinishedAt

Indicates when the Timer will be finished. If the DateTimeStamp is in the future, the timer is not yet finished. If the DateTimeStamp is in the past, the timer is finished. When the timer was never started, the value can be an arbitrary DateTimeStamp in the past.
has super-properties
has timestamp
has domain
Timerc
has range
date time stamp

is interruptibledp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/isInterruptible

This property indicates whether the PowerSequence is interruptible.
has domain
Power sequencec
has range
boolean

is obligatorydp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/isObligatory

A relationship between the power limit and the boolean value indicating whether the power limit is obligatory
has domain
Power Limitc
has range
boolean

is pausabledp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/isPausable

Specifies if the power sequence is pausable.
has range
boolean

is stoppabledp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/isStoppable

Specifies if the power sequence is stoppable.
has range
boolean

manufacturer descriptiondp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/manufacturerDescription

A description for the device as defined by the manufacturer.
has range
string

manufacturer labeldp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/manufacturerLabel

A short label of the device as defined by the manufacturer.
has range
string

manufacturer node identificationdp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/manufacturerNodeIdentification

Indicates a node identification for the device as defined by the manufacturer. This could be used for the identification of a device, even if it was removed from the network and rejoined later with changed node address.
has range
string

max cycles per daydp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/maxCyclesPerDay

States the maximum amount of starts a power sequence (of a device) allows per day.
has range
unsigned int

max pause beforedp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/hasMaxPauseBefore

The maximum duration for which a device can be paused between the end of the previous running sequence and the start of this one
has super-properties
duration in xsd dp
has domain
Power sequencec
has range
duration

measurement iddp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/measurementID

Enables the identification of different sensors on one EEBus address.
has range
unsigned int

messaging numberdp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/messagingNumber

An identifier for one specific message. If a message is marked as obsolete, this number can be used to identify the original message.
has range
unsigned int

messaging typedp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/messagingType

Indicates the type of the message. Possible values are: - logging (used for messages, that shall be stored in a log file) - information (messages, that shall be presented to the customer on a display; lower priority) - warning (messages, that shall be presented to the customer on a display; medium priority) - alarm (messages, that shall be presented to the customer on a display; high priority; if there is an alarm device in the household, it shall generate an alarm) - emergency (messages, that shall be presented to the customer on a display; very high priority; if there is an alarm device in the household, it shall generate an alarm; additionally, if possible and configured, an emergency call shall be done) - obsolete (previously sent messages, that shall be marked as obsolete)
has range
{ "alarm" , "emergency" , "information" , "logging" , "obsolete" , "warning" }

node remote controllabledp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/nodeRemoteControllable

Indicates whether the power profile of a device is configured for remote control (e.g., by an energy management system).This refers to the selection chosen by the user on the remote control feature of the device. If nodeRemoteControllable is equal to FALSE, all the supported power sequences shall set the sequenceRemoteControllable property to FALSE. If nodeRemoteControllable is equal to TRUE, at least one power sequence shall be remotely controllable by setting the sequenceRemoteControllable property to TRUE.
has range
boolean

optional slotdp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/optionalSlot

Indicates whether a slot is optional (if set to TRUE). Otherwise, if a slot is mandatory, SHALL be omitted or set to FALSE. Note: This element applies to every repetition of the slot number.
has range
boolean

Pause before Maximumdp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/hasMaxPauseDuration

The maximum duration for which a device can be paused between the end of the previous running sequence and the start of this one
has super-properties
duration in xsd dp
has domain
Power sequencec
has range
duration

progressdp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/progress

Time that has passed since the selected sequence has started. A value must be provided, unless no sequence has been selected or the selected sequence hasn't started yet.
has domain
Power profile containerc
has range
duration

repetition totaldp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/repetitionsTotal

Contains the total number of repetitions, if a power sequence repeats its sequence of slots. Absence of the element is equal to a presence with a value of 0 (zero). SHALL be absent if the value is 1.
has range
unsigned int

requiresUpdatedp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/requiresUpdate

The relationship between the incentive table element and the boolean data indicating whether the incentive table requires an update. In the SAREF4ENER extension this property is intended for the following classes: - IncentiveTableBasedProfile - IncentiveTableTier - IncentiveTableSlot
has range
boolean

sequence IDdp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/sequenceID

Provides a unique power sequence identifier for a certain device
has range
unsigned int

sequence remote controllabledp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/sequenceRemoteControllable

Denotes whether a power sequence is modifiable (if value is TRUE) or not (if value is FALSE). Modifiability is required to configure power sequences and slots. It is also required to change a power sequence state.
has range
boolean

serial numberdp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/serialNumber

Indicates the serial number of a device as defined by the manufacturer. Usually the same as printed on the case.
has range
string

slot activateddp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/slotActivated

If a slot is optional, represents the current status of the slot (true = the slot will be executed, false = the slot will not be executed). If the slot is not optional, this element SHALL be absent.
has range
boolean

slot numberdp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/slotNumber

Provides a unique slot identifier for a certain power sequence
has range
unsigned int

software revisiondp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/softwareRevision

Indicates the software revision of a device as defined by the manufacturer.
has range
string

supports reselectiondp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/supportsReselection

If set toTRUE, the power profile of a device does not restrict the number of power sequence re-selections by the CEM, i.e. within a given alternative the CEM may first choose one power sequence, alter the selection by configuring another sequence later on, then alter the selection again, etc. (provided the process rules and data still permit configuration). If supportsReselection is set to FALSE, the device permits the CEM to select a power sequence of an alternative only once.
has range
boolean

supports single slot scheduling onlydp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/supportsSingleSlotSchedulingOnly

If set toTRUE, the power profile of a device does NOT permit the modification of more than one slot per configuration command.
has range
boolean

task identifierdp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/taskIdentifier

Represents the task identifier of the power sequence.
has range
unsigned int

total sequences count maxdp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/totalSequencesCountMax

Represents the total number of power sequences supported by the power profile of a device
has range
unsigned int

Transition Durationdp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/hasTransitionDuration

Indicates the time between the initiation of this Transition, and the time at which the device behaves according to the Operation Mode which is defined in the appropriate data element. When no value is provided it is assumed the transition duration is negligible.
has super-properties
duration in xsd dp
has domain
Transitionc
has range
duration

transition Timestampdp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/hasTransitionTimestamp

Time at which the transition from the previous Operation Mode was initiated. This value shall always be provided, unless the active OperationMode is the first OperationMode the Resource Manager is aware of.
has super-properties
has timestamp
has domain
actuator or Operation Modec
has range
date time stamp

vendor codedp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/vendorCode

Provides a code for the vendor of the device as defined by the manufacturer.
has range
string

vendor namedp back to ToC or Data Property ToC

IRI: https://saref.etsi.org/saref4ener/vendorName

Provides the name of the vendor of the device as defined by the manufacturer.
has range
string

Named Individuals

Abortedni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/Aborted

Instruction was aborted.
belongs to
Instruction Statusc
Power sequence statusc

Absolute costni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/AbsoluteCost

The incentive type ''absolute cost'' defined in the incentive table.
belongs to
Incentive Typec

Acceptedni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/Accepted

Instruction has been accepted
belongs to
Instruction Statusc

Anais Walleni back to ToC or Named Individual ToC

IRI: https://www.linkedin.com/in/ana%C3%AFs-walle-050baa159/

Averageni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/Average

The datapoint indicates an average value aggregated over a number of values.
belongs to
Usagec

Baselineni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/BaseLine

This datapoint indicates the baseline.
belongs to
Usagec

Battery power sourceni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/BatteryPowerSource

This Power Source codelist element indicates that a battery is the power source of this device.
belongs to
Power sourcec

Calculatedni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/Calculated

This value source codelist element indicates that this measurement has been calculated instead of measured or empirical.
belongs to
Value sourcec

CO2 Emissionni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/CO2Emission

The incentive type ''CO2 Emission'' defined in the incentive table.
belongs to
Incentive Typec

Committedni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/Committed

The committed version of this concept, usually an incentive table or power plan
belongs to
Scope Typec

Completedni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/Completed

Power sequence state with value 'completed'
belongs to
Power sequence statec

Consumptionni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/Consumption

This datapoint indicates the consumption.
belongs to
Usagec

DC Power sourceni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/DCPowerSource

This Power Source codelist element indicates that the type of power source is DC.
belongs to
Power sourcec

Deferni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/Defer

Indicating that the limited load or generation will be postponed to a later moment
belongs to
Power Envelope Consequence Typec

Downflexni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/Downflex

This datapoint indicates the down flexibility.
belongs to
Usagec

Electric Power 3 Phase Symmetricni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/ElectricPower3PhaseSymmetric

Electric power described in Watt on when power is equally shared among the three phases. Only applicable for 3 phase devices.
belongs to
Commodity Quantityc

Electric Power L1ni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/ElectricPowerL1

Electric power described in Watt on phase 1. If a device utilizes only one phase it should always use L1.
belongs to
Commodity Quantityc

Electric Power L2ni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/ElectricPowerL2

Electric power described in Watt on phase 2. Only applicable for 3 phase devices.
belongs to
Commodity Quantityc

Electric Power L3ni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/ElectricPowerL3

Electric power described in Watt on phase 3. Only applicable for 3 phase devices.
belongs to
Commodity Quantityc

Electricityni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/Electricity

Identifier for Commodity ELECTRICITY
belongs to
electricity

Emergencyni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/Emergency

Load control event action with value 'emergency'
belongs to
Event action consumec
Event action producec

Empiricalni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/Empirical

This value source codelist element indicates this value is an empirical value instead of a calculated or measured value.
belongs to
Value sourcec

Energy Consumerni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/EnergyConsumer

Identifier for RoleType Consumer
belongs to
Role Typec

Energy Producerni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/EnergyProducer

Identifier for RoleType Producer
belongs to
Role Typec

Energy Storageni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/EnergyStorage

Identifier for RoleType Storage
belongs to
Role Typec

Euro per kilo watt hourni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/EuroPerKilowattHour

Unit of Measure to represent euro's per kilowatt per hour
belongs to
unit of measure

Event acceptedni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/EventAccepted

Load control state with value 'event accepted'
belongs to
Event state consumec
Event state producec

Event cancelledni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/EventCancelled

Load control state with value 'event cancelled'
belongs to
Event state consumec
Event state producec

Event errorni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/EventError

Load control state with value 'event error'
belongs to
Event state consumec
Event state producec

Event rejectedni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/EventRejected

Load control state with value 'event rejected'
belongs to
Event state consumec
Event state producec

Event startedni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/EventStarted

Load control state with value 'event started'
belongs to
Event state consumec
Event state producec

Event stoppedni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/EventStopped

Load control state with value 'event stopped'
belongs to
Event state consumec
Event state producec

EXECUTINGni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/Executing

The selected PPBC.PowerSequence is currently being executed
belongs to
Power sequence statusc

Fallingni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/Falling

This value tendency codelist element indicates that the tendency of this measurement indicates that the value is decreasing (i.e., falling).
belongs to
Value tendencyc

Finishedni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/Finished

The selected PPBC.PowerSequence was executed and finished successfully
belongs to
Power sequence statusc

Gasni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/Gas

Identifier for Commodity GAS
belongs to
gas

Georg Jungni back to ToC or Named Individual ToC

IRI: https://www.linkedin.com/in/georgjung/

George Hallakni back to ToC or Named Individual ToC

IRI: https://www.linkedin.com/in/george-hallak-368301157/

Heatni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/Heat

Identifier for Commodity Heat
belongs to
commodity

Heat Flow Rateni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/HeatFlowRate

Flow rate of heat carrying gas or liquid in liters per second
belongs to
Commodity Quantityc

Heat Temperatureni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/HeatTemperature

Heat described in degrees Celsius
belongs to
Commodity Quantityc

Heat Thermal Powerni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/HeatThermalPower

Thermal power in Watt
belongs to
Commodity Quantityc

Hydrogen Flow Rateni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/HydrogenFlowRate

Gas flow rate described in grams per second
belongs to
Commodity Quantityc

Inactiveni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/Inactive

Power sequence state with value 'inactive'
belongs to
Power sequence statec

Increaseni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/Increase

Load control event action with value 'increase'
belongs to
Event action consumec
Event action producec

Interruptedni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/Interrupted

The selected PPBC.PowerSequence is being executed, but is currently interrupted and will continue afterwards
belongs to
Power sequence statusc

Invalidni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/Invalid

Power sequence state with value 'invalid'
belongs to
Power sequence statec

Josef Baumeisterni back to ToC or Named Individual ToC

IRI: https://www.linkedin.com/in/josef-baumeister-a221422/

Lower Limitni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/LowerLimit

The PowerEnvelopeLimitType codelist element indicating the lower limit.
belongs to
Power Envelope Limit Typec
Usagec

Mains single phaseni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/MainsSinglePhase

This codelist element of power source indicates that the power source is the mains single phase.
belongs to
Power sourcec

Mains3Phaseni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/Mains3Phase

This Power Source codelist element indicates that the power source of this device is Mains 3 Phase.
belongs to
Power sourcec

Maximumni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/Maximum

The usage of this datapoint is the Maximum value.
belongs to
Usagec

Measuredni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/Measured

The value source type indicates that this data point has been measured by a device.
belongs to
Value sourcec

Minimumni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/Minimum

The usage of this datapoint is the Minimum value.
belongs to
Usagec

Natural Gas Flow Rateni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/NaturalGasFlowRate

Gas flow rate described in liters per second
belongs to
Commodity Quantityc

Newni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/New

Instruction was newly created
belongs to
Instruction Statusc

Normalni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/Normal

The value NORMAL used to instantiate the Load Control Event Action class and MeasurandState class
belongs to
Event action consumec
Event action producec

NotScheduledni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/NotScheduled

No PPBC.PowerSequence within the PPBC.PowerSequenceContainer is scheduled
belongs to
Power sequence statusc

Oilni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/Oil

Identifier for Commodity OIL
belongs to
commodity

Oil Flow Rateni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/OilFlowRate

Oil flow rate described in liters per hour
belongs to
Commodity Quantityc

Pauseni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/Pause

Load control event action with value 'pause'
belongs to
Event action consumec
Event action producec

Pausedni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/Paused

Power sequence state or sensor state with value 'paused'
belongs to
Power sequence statec

Pendingni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/Pending

Power sequence state with value 'pending'
belongs to
Power sequence statec

Preliminaryni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/Preliminary

The preliminary version of this concept, usually an incentive table or power plan
belongs to
Scope Typec

Productionni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/Production

This datapoint indicates the energy production.
belongs to
Usagec

Reduceni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/Reduce

Load control event action with value 'reduce'
belongs to
Event action consumec
Event action producec

Rejectedni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/Rejected

Instruction was rejected
belongs to
Instruction Statusc

Relative costni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/RelativeCost

The incentive type ''relative cost'' defined in the incentive table.
belongs to
Incentive Typec

Renewable energy percentageni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/RenewableEnergyPercentage

The incentive type ''renewable energy percentage'' defined in the incentive table.
belongs to
Incentive Typec

Resumeni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/Resume

Load control event action with value 'resume'
belongs to
Event action consumec
Event action producec

Revokedni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/Revoked

Instruction was revoked
belongs to
Instruction Statusc

Risingni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/Rising

This value tendency codelist element indicates that the tendency of this measurement indicates that the value is increasing (i.e., rising).
belongs to
Value tendencyc

Runningni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/Running

Power sequence state with value 'running'
belongs to
Power sequence statec

Scheduledni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/Scheduled

Power sequence state with value 'scheduled'
belongs to
Power sequence statec

Scheduled pausedni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/ScheduledPaused

Power sequence state with value 'scheduled paused'
belongs to
Power sequence statec

Setpointni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/SetPoint

This datapoint indicates a setpoint.
belongs to
Usagec

Stableni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/Stable

This value tendency codelist element indicates that the tendency this measurement has is to stay stable, instead of rising or falling.
belongs to
Value tendencyc

Startedni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/Started

Instruction was executed
belongs to
Instruction Statusc

Succeededni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/Succeeded

Instruction finished successfully
belongs to
Instruction Statusc

Upflexni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/Upflex

This datapoint indicates the upper flexibility.
belongs to
Usagec

Upper Limitni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/UpperLimit

The PowerEnvelopeLimitType enumeration for the upper limit.
belongs to
Power Envelope Limit Typec
Usagec

Vanishni back to ToC or Named Individual ToC

IRI: https://saref.etsi.org/saref4ener/Vanish

The load or generation that is limited will vanish. This is for example the case with curtailing production from solar panels; the potentially generated energy is lost and will never reappear.
belongs to
Power Envelope Consequence Typec

Wilco Wijbrandini back to ToC or Named Individual ToC

IRI: https://www.linkedin.com/in/wilco-wijbrandi-3994ab4b/

Annotation Properties

contributorap back to ToC or Annotation Property ToC

IRI: http://purl.org/dc/terms/contributor

preferred namespace prefixap back to ToC or Annotation Property ToC

IRI: http://purl.org/vocab/vann/preferredNamespacePrefix

preferred namespace uriap back to ToC or Annotation Property ToC

IRI: http://purl.org/vocab/vann/preferredNamespaceUri

Namespace Declarations back to ToC

default namespace
https://saref.etsi.org/saref4ener/
0-1
http://xmlns.com/foaf/0.1/
01-02-01-60
https://www.etsi.org/deliver/etsi_ts/103400_103499/10341001/01.02.01_60/
core
https://saref.etsi.org/core/
forge-etsi-org
https://forge.etsi.org/
in
https://www.linkedin.com/in/
owl
http://www.w3.org/2002/07/owl#
rdf
http://www.w3.org/1999/02/22-rdf-syntax-ns#
rdfs
http://www.w3.org/2000/01/rdf-schema#
terms
http://purl.org/dc/terms/
time
http://www.w3.org/2006/time#
vann
http://purl.org/vocab/vann/
xsd
http://www.w3.org/2001/XMLSchema#

This HTML document was obtained by processing the OWL ontology source code through LODE, Live OWL Documentation Environment, developed by Silvio Peroni .